A Novel Approach to High-temperature In-situ Ultrasonic NDE Using Magnetostriction
Online ultrasonic NDE at high-temperature is of much interest to the power, process and automotive industries in view of possible savings in down-time. This paper describes a novel approach to develop ultrasonic transducers capable of high-temperature in-situ operation using the principle of magnetostriction. Preliminary design from previous research by the authors is extended for operation at 1 MHz, and elevated temperatures by using MetGlas s the magnetostrictive core. Ultrasonic signals in pulse-echo mode are experimentally obtained from the ultrasonic transducer thus developed, in simulated high temperature environment of 350 °C for 10 hours. Advantages and challenges for practical deployment of this approach are discussed
A Novel Approach to High-temperature In-situ Ultrasonic NDE Using Magnetostriction
Online ultrasonic NDE at high-temperature is of much interest to the power, process and automotive industries in view of possible savings in down-time. This paper describes a novel approach to develop ultrasonic transducers capable of high-temperature in-situ operation using the principle of magnetostriction. Preliminary design from previous research by the authors is extended for operation at 1 MHz, and elevated temperatures by using MetGlas s the magnetostrictive core. Ultrasonic signals in pulse-echo mode are experimentally obtained from the ultrasonic transducer thus developed, in simulated high temperature environment of 350 °C for 10 hours. Advantages and challenges for practical deployment of this approach are discussed.</p