26 research outputs found

    Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study

    Get PDF
    The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8–8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two observers correctly identified respectively 10/15 (67%) and 9/15 (60%) polyps ≥10 mm, with 5 and 8 false-positive lesions (standard dose scan). Dose reduction down to 0.7 mSv was not associated with significant changes in diagnostic value (polyps ≥10 mm). Eighty percent of patients preferred CT colonography and 13% preferred colonoscopy (P<0.001). CT colonography without cleansing is preferred to colonoscopy and shows sufficient image quality and moderate sensitivity, without impaired diagnostic value at dose-levels as low as 0.7 mSv

    Dose Reduction in Screening Programs: Colon Cancer Screening

    No full text

    Diagnostic value of CT-colonography as compared to colonoscopy in an asymptomatic screening population: a meta-analysis

    Get PDF
    Previous meta-analyses on CT-colonography included both average and high risk individuals, which may overestimate the diagnostic value in screening. A meta-analysis was performed to obtain the value of CT-colonography for screening. A search was performed using PubMed, Embase and Cochrane. Article selection and critical appraisal was done by two reviewers. Inclusion criteria: prospective, randomized trials or cohort studies comparing CT-colonography with colonoscopy (≥50 participants), ≥95% average risk participants ≥50 years. Study characteristics and 2 × 2 contingency Tables were recorded. Sensitivity and specificity estimates were calculated per patient and per polyp (≥6 mm, ≥10 mm), using univariate and bivariate analyses. Five of 1,021 studies identified were included, including 4,086 participants ( <1% high risk). I(2)-values showed substantial heterogeneity, especially for 6-9 mm polyps and adenomas: 68.1% vs. 78.6% (sensitivity per patient). Estimated sensitivities for patients with polyps or adenomas ≥ 6 mm were 75.9% and 82.9%, corresponding specificities 94.6% and 91.4%. Estimated sensitivities for patients with polyps or adenomas ≥ 10 mm were 83.3% and 87.9%, corresponding specificities 98.7% and 97.6%. Estimated sensitivities per polyp for advanced adenomas ≥ 6 mm and ≥ 10 mm were 83.9% and 83.8%. Compared to colonoscopy, CT-colonography has a high sensitivity for adenomas ≥ 10 mm. For (advanced) adenomas ≥ 6 mm sensitivity is somewhat lowe

    Percutaneous Treatment of Common Bile Duct Stones: Results and Complications in 110 Consecutive Patients

    No full text
    Background/Aims: Choledocholithiasis is a common complication of cholecystolithiasis, occurring in 15-20% of patients who have gallbladder stones. Endoscopic retrograde cholangio-pancreatography is the standard treatment. When this is not possible or not feasible, percutaneous transhepatic stone removal is an alternative treatment. In this retrospective study, we analyze 110 patients who were treated with percutaneous transhepatic removal of Common Bile Duct (CBD) stones. Patients and Methods: Between March 1998 and September 2013 110 patients (61 men, 49 women; aged 14-96, mean age 69.7 years) with confirmed bile duct stones were included. PTC was done using ultrasound and fluoroscopy. Balloon dilatation of the papilla was done with 8-12 mm balloons. If stone size exceeded 10 mm, mechanical lithotripsy was performed. Stones were then removed by percutaneous extraction or evacuation into the duodenum. Results: In 104 patients (104/110; 94.5%) total stone clearance of the CBD was achieved. A total of 12 complications occurred (10.9%), graded with the Clavien-Dindo scale as IVa, IVb, and V. respectively; hypoxia requiring resuscitation, sepsis and death due to ongoing cholangiosepsis (n = 1, 4, 1). Minor complications I, II, and IIIa included: small liver abscess, pleural empyema, transient hennobilia and mild fever (n = 1, 1, 2, 2). Conclusion: Percutaneous removal of CBD stones is an effective alternative treatment, when endoscopic treatment is contra-indicated, fails or is not feasible. It is effective, has a low complication rate and using deep sedation potentially requires only a very limited number of treatment sessions. (C) 2015 S. Karger AG, Base

    Image quality and patient acceptance of four regimens with different amounts of mild laxatives for CT colonography

    No full text
    OBJECTIVE: The purpose of our study was to prospectively evaluate image quality and patient acceptance of CT colonography (CTC) with fecal tagging using different levels of catharsis. SUBJECTS AND METHODS: Forty consecutive increased-risk patients were randomized. Group 1 received orally 20 mg of bisacodyl, group 2 received 30 mg of bisacodyl, group 3 received 20 mg of bisacodyl and 8.2 g of magnesium citrate, and group 4 received 30 mg of bisacodyl and 16.4 g of magnesium citrate. All patients used a 2-day low-fiber diet and received diatrizoate meglumine and barium for fecal tagging. One reviewer blindly scored subjective image quality (fecal tagging, amount of residual feces [liquid or solid], luminal distention, and image readability) on a 5- to 6-point scale using a 2D review technique. The mean and SD of attenuation of tagging were measured as well as the relative SD as a measure of homogeneity. Furthermore, patient acceptance (burden related to diarrhea, abdominal pain, flatulence, and overall burden) was evaluated. Ordinal regression, generalized estimating equations, and parametric and nonparametric tests were used for analysis. RESULTS: Image readability was evaluated as good or excellent in all examinations except one in group 2 (nondiagnostic) and two in group 3 (moderate). Group 2 contained more feces than group 4 (p = 0.04). With regard to mean attenuation and homogeneity of tagging, no significant differences were observed between groups. Group 4 experienced more severe diarrhea than groups 1 and 2 and higher overall burden than groups 1 and 3 (p < 0.042). CONCLUSION: The mildest preparation with 20 mg of bisacodyl provided good image quality of CTC images. Increasing the amount of laxatives did not improve image quality or tagging characteristics but was associated with a lower patient acceptanc

    Effective radiation doses in CT colonography: results of an inventory among research institutions

    No full text
    The purpose of this study was to estimate the effective dose that is currently used in CT colonography using scan parameters that were collected for this purpose, and to investigate trends in time. PubMed was systematically searched from 1996 until January 2004 for studies investigating CT colonography. Research institutions were contacted and asked for their current scan protocol. Thirty-six institutions published 74 studies. Twenty-eight of the 36 institutions provided their current protocol. The median effective dose in 2004 was 5.1 mSv (range 1.2-11.7 mSv) per position. Most institutions (93%) scan in both the supine and prone positions. The median mAs value was 67 mAs (range 20-200), median collimation was 2.5 mm (range 0.75-5). From 1996 until 2004 a significant decrease in mAs and collimation (P=0.006, P <0.0001, respectively) was observed, while institutions that used a multislice scanner increased (P <0.0001). The effective dose remained constant (P=0.76). In 2004 the median effective dose for a complete CT colonography was 10.2 mSv. Despite the increasing use of multislice scanners, which are slightly less dose-efficient, the median effective dose remained approximately constant between 1996 and 2004. This is mainly caused by the use of lower mAs setting

    Admission blood glucose level as risk indicator of death after myocardial infarction in patients with and without diabetes mellitus

    No full text
    High admission blood glucose levels after acute myocardial infarction (AMI) are common and associated with an increased risk of death in subjects with and without known diabetes. Recent data indicate a high prevalence of abnormal glucose metabolism in patients with unknown diabetes at the time of AMI. We investigated the predictive value of admission blood glucose levels after AMI for long-term prognosis in patients with and without previously diagnosed diabetes mellitus, particularly in those with unknown diabetes but with blood glucose levels in the diabetic range. In a retrospective study with prospective follow-up, 846 patients (737 without and 109 with known diabetes) were eligible for follow-up during a median of 50 months (range, 0-93 months). During follow-up, 208 nondiabetic patients (28.2%) and 47 diabetic patients (43.1%) died (P =.002). An increase of 18 mg/dL (1 mmol/L) in glucose level was associated with a 4% increase of mortality risk in nondiabetic patients and 5% in diabetic patients (both P <.05). Of the 737 previously nondiabetic subjects, 101 had admission blood glucose levels of 200 mg/dL (11.1 mmol/L) or more, and mortality in these patients was comparable to that in patients who had established diabetes (42.6% vs 43.1%). Admission blood glucose level after AMI is an independent predictor of long-term mortality in patients with and without known diabetes. Subjects with unknown diabetes and admission glucose levels of 200 mg/dL (11.1 mmol/L) or more after AMI have mortality rates comparable to those of subjects with established diabetes. Admission blood glucose level may serve to identify subjects at high long-term mortality risk, in particular among those with unknown diabete
    corecore