41 research outputs found
Floating-disk parylene microvalve for self-regulating biomedical flow controls
A novel self-regulating parylene micro valve is presented in this paper with potential applications for biomedical flow controls. Featuring a free-floating bendable valve disk and two-level valve seat, this surface-micromachined polymeric valve accomplishes miniature pressure/flow rate regulation in a band-pass profile stand-alone without the need of power sources or active actuation. Experimental data of underwater testing results have successfully demonstrated that the microfabricated in-channel valve can regulate water flow at 0-80 mmHg and 0-10 µL/min pressure/flow rate level, which is perfectly suitable for biomedical and lab-on-a-chip applications. For example, such biocompatible microvalve can be incorporated in ocular implants for control of eye fluid drainage to fulfill intraocular pressure (IOP) regulation in glaucoma patients
Robust parylene-to-silicon mechanical anchoring
This paper describes a new technique for strongly anchoring parylene (poly-para-xylylene) layers on a silicon substrate. Parylene has gained interest for MEMS applications due to its excellent properties. More specifically, because of its flexibility (Young's modulus of 4 GPa), its chemical barrier properties, its conformal deposition and its biocompatibility, parylene is of great interest for microfluidics and BioMEMS. One of the issues with parylene processing is adhesion and delamination problems, occurring during fabrication or during device operation. Here, we report a new technique for anchoring parylene films on silicon using DRIE-etched trenches and anchors. We demonstrate a new way to completely protect the adhesion of parylene even when exposed to aggressive chemicals
Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors
This paper presents an implantable parylene-based wireless pressure sensor for biomedical pressure sensing applications specifically designed for continuous intraocular pressure (IOP) monitoring in glaucoma patients. It has an electrical LC tank resonant circuit formed by an integrated capacitor and an inductor coil to facilitate passive wireless sensing using an external interrogating coil connected to a readout unit. Two surface-micromachined sensor designs incorporating variable capacitor and variable capacitor/inductor resonant circuits have been implemented to realize the pressure-sensitive components. The sensor is monolithically microfabricated by exploiting parylene as a biocompatible structural material in a suitable form factor for minimally invasive intraocular implantation. Pressure responses of the microsensor have been characterized to demonstrate its high pressure sensitivity (> 7000 ppm/mmHg) in both sensor designs, which confirms the feasibility of pressure sensing with smaller than 1 mmHg of resolution for practical biomedical applications. A six-month animal study verifies the in vivo bioefficacy and biostability of the implant in the intraocular environment with no surgical or postoperative complications. Preliminary ex vivo experimental results verify the IOP sensing feasibility of such device. This sensor will ultimately be implanted at the pars plana or on the iris of the eye to fulfill continuous, convenient, direct, and faithful IOP monitoring
Implantable parylene-based wireless intraocular pressure sensor
This paper presents a novel implantable, wireless,
passive pressure sensor for ophthalmic applications. Two
sensor designs incorporating surface-micromachined
variable capacitor and variable capacitor/inductor are
implemented to realize the pressure sensitive components.
The sensor is monolithically microfabricated using parylene
as a biocompatible structural material in a suitable form
factor for increased ease of intraocular implantation.
Pressure responses of the microsensor are characterized
on-chip to demonstrate its high pressure sensitivity (> 7000
ppm/mmHg) with mmHg level resolution. An in vivo animal
study verifies the biostability of the sensor implant in the
intraocular environment after more than 150 days. This
sensor will ultimately be implanted at the pars plana or iris of
the eye to fulfill continuous intraocular pressure (IOP)
monitoring in glaucoma patients
Implantable Unpowered Parylene MEMS Intraocular Pressure Sensor
This paper presents the first implantable, unpowered, parylene-based micro-electro-mechanical-systems (MEMS) pressure sensor for intraocular pressure (IOP) sensing. From in situ mechanical deformation of the compliant structures, this sensor registers pressure variations without power consumption/transduction. Micromachined high-aspect-ratio thin-walled tubes in different geometric layouts are exploited to obtain a high-sensitivity pressure response. An integrated packaging method has been successfully developed to realize suture-less implantation of the device. In vitro testing results have demonstrated that the IOP sensor can achieve 0.67 degree/mmHg angular sensitivity with a spiral-tube design, 3.43 µm/mmHg lateral sensitivity with a long-armed-tube design, and 0.38 µm/mmHg longitudinal sensitivity with a serpentine-tube design. This IOP sensor is designed to be implanted in the anterior chamber of the eye and anchored directly on the iris so that, under incident visible light, the pressure response of the implant can be directly observed from outside the eye, which enables faithful and unpowered IOP monitoring in glaucoma patient
Wafer-Level Parylene Packaging With Integrated RF Electronics for Wireless Retinal Prostheses
This paper presents an embedded chip integration
technology that incorporates silicon housings and flexible
Parylene-based microelectromechanical systems (MEMS) devices.
Accelerated-lifetime soak testing is performed in saline at elevated
temperatures to study the packaging performance of Parylene C
thin films. Experimental results show that the silicon chip under
test is well protected by Parylene, and the lifetime of Parylenecoated
metal at body temperature (37°C) is more than 60 years,
indicating that Parylene C is an excellent structural and packaging
material for biomedical applications. To demonstrate the proposed
packaging technology, a flexible MEMS radio-frequency (RF) coil
has been integrated with an RF identification (RFID) circuit die.
The coil has an inductance of 16 ÎĽH with two layers of metal
completely encapsulated in Parylene C, which is microfabricated
using a Parylene–metal–Parylene thin-film technology. The chip
is a commercially available read-only RFID chip with a typical
operating frequency of 125 kHz. The functionality of the embedded
chip has been tested using an RFID reader module in both air
and saline, demonstrating successful power and data transmission
through the MEMS coil
Microelectronic packaging for retinal prostheses
The retinal prosthesis initiative at the Biomimetic Microelectronic Systems (BMES) center, an National Science Foundation (NSF) Engineering Research Center (ERC) at the University of Southern California (USC), the California Institute of Technology (Caltech), and the University of California, Santa Cruz, calls for a novel set of packaging technologies for bioimplant device construction. The testbed requires high-resolution electrical stimulation of the remaining functional neurons of the macula and a mechanically and electrically robust method for interconnecting application-specific integrated circuits (ASICs) with the interfacial electrodes. Our epiretinal prosthesis comprises a video-capture and data-encoding mechanism, a radio-frequency (RF) coil system for power and data transmission and recovery, an analog/digital ASIC with driving electronics, and a flexible retinotopic electrode array for neural stimulation, all in a chronically implantable, hermetically sealed package. Here, we discuss an innovative parylene-based high-density chip-level integrated interconnect (CL-I2) packaging system for retinal implants
Implantable micromechanical parylene-based pressure sensors for unpowered intraocular pressure sensing
This paper presents the first implantable, unpowered, parylene-based microelectromechanical system (MEMS) pressure sensor for intraocular pressure (IOP) sensing. From in situ mechanical deformation of the compliant spiral-tube structures, this sensor registers pressure variations without electrical or powered signal transduction of any kind. Micromachined high-aspect-ratio polymeric hollow tubes with different geometric layouts are implemented to obtain high-sensitivity pressure responses. An integrated device packaging method has been developed toward enabling minimally invasive suture-less needle-based implantation of the device. Both in vitro and ex vivo device characterizations have successfully demonstrated mmHg resolution of the pressure responses. In vivo animal experiments have also been conducted to verify the biocompatibility and functionality of the implant fixation method inside the eye. Using the proposed implantation scheme, the pressure response of the implant can be directly observed from outside the eye under visible light, with the goal of realizing convenient, direct and faithful IOP monitoring in glaucoma patients