110 research outputs found
Laboratory Measurements Of White Dwarf Photospheric Spectral Lines: H Beta
We spectroscopically measure multiple hydrogen Balmer line profiles from laboratory plasmas to investigate the theoretical line profiles used in white dwarf (WD) atmosphere models. X-ray radiation produced at the Z Pulsed Power Facility at Sandia National Laboratories initiates plasma formation in a hydrogen-filled gas cell, replicating WD photospheric conditions. Here we present time-resolved measurements of H beta and fit this line using different theoretical line profiles to diagnose electron density, n(e), and n = 2 level population, n2. Aided by synthetic tests, we characterize the validity of our diagnostic method for this experimental platform. During a single experiment, we infer a continuous range of electron densities increasing from n(e) similar to 4 to similar to 30 x 10(16) cm(-3) throughout a 120-ns evolution of our plasma. Also, we observe n(2) to be initially elevated with respect to local thermodynamic equilibrium (LTE); it then equilibrates within similar to 55 ns to become consistent with LTE. This supports our electrontemperature determination of T-e similar to 1.3 eV (similar to 15,000 K) after this time. At n(e) greater than or similar to 10(17) cm(-3), we find that computer-simulation-based line-profile calculations provide better fits (lower reduced chi(2)) than the line profiles currently used in the WD astronomy community. The inferred conditions, however, are in good quantitative agreement. This work establishes an experimental foundation for the future investigation of relative shapes and strengths between different hydrogen Balmer lines.Laboratory Directed Research and Development programUnited States Department of Energy DE-AC04-94AL85000, DE-SC0010623National Science Foundation DGE-1110007Astronom
The Star-forming Region NGC 346 in the Small Magellanic Cloud with Hubble Space Telescope ACS Observations. II. Photometric Study of the Intermediate-Age Star Cluster BS 90
We present the results of our investigation of the intermediate-age star
cluster BS 90, located in the vicinity of the HII region N 66 in the SMC,
observed with HST/ACS. The high-resolution data provide a unique opportunity
for a very detailed photometric study performed on one of the rare
intermediate-age rich SMC clusters. The complete set of observations is
centered on the association NGC 346 and contains almost 100,000 stars down to V
~28 mag. In this study we focus on the northern part of the region, which
covers almost the whole stellar content of BS 90. We construct its stellar
surface density profile and derive structural parameters. Isochrone fits on the
CMD of the cluster results in an age of about 4.5 Gyr. The luminosity function
is constructed and the present-day mass function of BS 90 has been obtained
using the mass-luminosity relation, derived from the isochrone models. We found
a slope between -1.30 and -0.95, comparable or somewhat shallower than a
typical Salpeter IMF. Examination of the radial dependence of the mass function
shows a steeper slope at larger radial distances, indicating mass segregation
in the cluster. The derived half-mass relaxation time of 0.95 Gyr suggests that
the cluster is mass segregated due to its dynamical evolution. From the
isochrone model fits we derive a metallicity for BS 90 of [Fe/H]=-0.72, which
adds an important point to the age-metallicity relation of the SMC. We discuss
our findings on this relation in comparison to other SMC clusters.Comment: Accepted for Publication in ApJ, 12 pages emulateapj TeX style, 10
figure
Development of a microchannel plate based gated x-ray imager for imaging and spectroscopy experiments on z
This poster describes a microchannelplate (MCP)–based, gated x-ray imager developed by National Security Technologies, LLC (NSTec), and Sandia National Laboratories(SNL) over the past several years. The camera consists of a 40 mm × 40 mm MCP, coated with eight 4 mm wide microstrips. The camera is gated by sending subnanosecond high-voltage pulses across the striplines. We have performed an extensive characterization of the camera, the results of which we present here. The camera has an optical gate profile width (time resolution) as narrow as 150 ps and detector uniformity of better than 30% along the length of a strip, far superior than what was achieved in previous designs. The spatial resolution is on the order of 40 microns for imaging applications and a dynamic range of between ~100 and ~1000. We also present results from a Monte Carlo simulation code developed by NSTec over the last several years. Agreement between the simulation results and the experimental measurements is very good
Design of the PST: A Diagnostic for 1-D Imaging of Fast Z-pinch Power Emissions RECE!PED
Fast Z-pinch technology developed on the Z machine at Sandia National Laboratones can produce up to 230 TW of thermal x-ray power for applications in inertial confinement fusion (ICF) and weapons physics experiments. During implosion, these Z-pinches develop Rayleigh-Taylor (R-T) instabilities which are very difficult to diagnose and which functionally diminish the overall pinch quality. The Power-Space-Time (PST) instrument is a newly configured diagnostic for measuring the pinch power as a function of both space and time in a Z-pinch. Placing the diagnostic at 90 degrees from the Z-pinch axis, the PST provides a new capability in collecting experimental data on R-T characteristics for making meaningful comparisons to magneto-hydrodynamic computer models. This paper is a summary of the PST diagnostic design. By slit-imaging the Z-pinch xray emissions onto a linear scintillator/fiber-optic array coupled to a streak camera system, the PST can achieve -100~m spatial resolution and -1.3 ns time resolution. Calculations indicate that a 20~m thick scintillating detection element filtered by 1000~of Al is theoretically linear in response to Plankian x-ray distributions corresponding to plasma temperatures from 40 eV to 150 eV, By calibrating this detection element to x-ray energies up to 5000 eV, the PST can provide pinch power as a function of height and time in a Z-pinch for temperatures ranging from -40 eV to -400 eV. With these system pm-meters, the PST can provide data for an experimental determination of the R-T mode number, amplitude, and growth rate during the late-time pinch implosion
Recommended from our members
An Inertial-Fusion Z-Pinch Power Plant Concept
With the promising new results of fast z-pinch technology developed at Sandia National Laboratories, we are investigating using z-pinch driven high-yield Inertial Confinement Fusion (ICF) as a fusion power plant energy source. These investigations have led to a novel fusion system concept based on an attempt to separate many of the difficult fusion engineering issues and a strict reliance on existing technology, or a reasonable extrapolation of existing technology, wherever possible. In this paper, we describe the main components of such a system with a focus on the fusion chamber dynamics. The concept works with all of the electrically-coupled ICF proposed fusion designs. It is proposed that a z-pinch driven ICF power system can be feasibly operated at high yields (1 to 30 GJ) with a relatively low pulse rate (0.01-0.1 Hz). To deliver the required current from the rep-rated pulse power driver to the z-pinch diode, a Recyclable Transmission Line (RTL) and the integrated target hardware are fabricated, vacuum pumped, and aligned prior to loading for each power pulse. In this z-pinch driven system, no laser or ion beams propagate in the chamber such that the portion of the chamber outside the RTL does not need to be under vacuum. Additionally, by utilizing a graded-density solid lithium or fluorine/lithium/beryllium eutectic (FLiBe) blanket between the source and the first-wall the system can breed its own fuel absorb a large majority of the fusion energy released from each capsule and shield the first-wall from a damaging neutron flux. This neutron shielding significantly reduces the neutron energy fluence at the first-wall such that radiation damage should be minimal and will not limit the first-wall lifetime. Assuming a 4 m radius, 8 m tall cylindrical chamber design with an 80 cm thick spherical FLiBe blanket, our calculations suggest that a 20 cm thick 6061-T6 Al chamber wall will reach the equivalent uranium ore radioactivity level within 100 years after a 30 year plant operation. The implication of this low radioactivity is that a z-pinch driven power plant may not require deep geologic waste storage
- …