21,092 research outputs found

    Pilot reliability investigation: final report on agreement PD/28/035/ADM

    Get PDF
    The feasibility of constructing a device to give a measure of pilot reliability has been investigated. A rig to meet the proposals made by BLEU has been designed and basic circuits constructed and tested for accuracy of operation and reliability. An estimate of the materials required and the cost of construction has been made. The rig has been designed to be subject operated for twentyfour tests before requiring attention, and devices have been incorporated to indicate unserviceability and prevent operation if starting cond4 tions are not correct. Switching sequences typical of the final period of an autoland approach are demanded verbally by magnetic tape replay equipment and the performance of the subject measured. The test consists of two phases; a preparatory or "unloaded" phase, and a "loaded" phase during which the subject performs a tracking task in addition to the switching sequence. The performance of the subject is recorded on veeder counters for both phases of the test in the form of actions demanded, actions taken and actions taken during a memory period. A measure of performance of the tracking task is also given by veeder counter

    On the pathwidth of almost semicomplete digraphs

    Full text link
    We call a digraph {\em hh-semicomplete} if each vertex of the digraph has at most hh non-neighbors, where a non-neighbor of a vertex vv is a vertex u≠vu \neq v such that there is no edge between uu and vv in either direction. This notion generalizes that of semicomplete digraphs which are 00-semicomplete and tournaments which are semicomplete and have no anti-parallel pairs of edges. Our results in this paper are as follows. (1) We give an algorithm which, given an hh-semicomplete digraph GG on nn vertices and a positive integer kk, in (h+2k+1)2knO(1)(h + 2k + 1)^{2k} n^{O(1)} time either constructs a path-decomposition of GG of width at most kk or concludes correctly that the pathwidth of GG is larger than kk. (2) We show that there is a function f(k,h)f(k, h) such that every hh-semicomplete digraph of pathwidth at least f(k,h)f(k, h) has a semicomplete subgraph of pathwidth at least kk. One consequence of these results is that the problem of deciding if a fixed digraph HH is topologically contained in a given hh-semicomplete digraph GG admits a polynomial-time algorithm for fixed hh.Comment: 33pages, a shorter version to appear in ESA 201

    Information requirements for enterprise systems

    Get PDF
    In this paper, we discuss an approach to system requirements engineering, which is based on using models of the responsibilities assigned to agents in a multi-agency system of systems. The responsibility models serve as a basis for identifying the stakeholders that should be considered in establishing the requirements and provide a basis for a structured approach, described here, for information requirements elicitation. We illustrate this approach using a case study drawn from civil emergency management

    Shades of Grey: Ethical Dilemmas

    Get PDF
    No abstract available

    Influence of 100% and 40% oxygen on penumbral blood flow, oxygen level, and T2*-weighted MRI in a rat stroke model

    Get PDF
    Accurate imaging of the ischemic penumbra is a prerequisite for acute clinical stroke research. T2* magnetic resonance imaging (MRI) combined with an oxygen challenge (OC) is being developed to detect penumbra based on changes in blood deoxyhemoglobin. However, inducing OC with 100% O2 induces sinus artefacts on human scans and influences cerebral blood flow (CBF), which can affect T2* signal. Therefore, we investigated replacing 100% O2 OC with 40% O2 OC (5 minutes 40% O2 versus 100% O2) and determined the effects on blood pressure (BP), CBF, tissue pO2, and T2* signal change in presumed penumbra in a rat stroke model. Probes implanted into penumbra and contralateral cortex simultaneously recorded pO2 and CBF during 40% O2 (n=6) or 100% O2 (n=8) OC. In a separate MRI study, T2* signal change to 40% O2 (n=6) and 100% O2 (n=5) OC was compared. Oxygen challenge (40% and 100% O2) increased BP by 8.2% and 18.1%, penumbra CBF by 5% and 15%, and penumbra pO2 levels by 80% and 144%, respectively. T2* signal significantly increased by 4.56%±1.61% and 8.65%±3.66% in penumbra compared with 2.98%±1.56% and 2.79%±0.66% in contralateral cortex and 1.09%±0.82% and −0.32%±0.67% in ischemic core, respectively. For diagnostic imaging, 40% O2 OC could provide sufficient T2* signal change to detect penumbra with limited influence in BP and CBF
    • 

    corecore