5 research outputs found

    Patient-Specific Finite-Element Analysis of Three Intramedullary Nails for Tibiotalocalcaneal Fusion

    No full text
    Category: Ankle, Hindfoot Introduction/Purpose: Tibiotalocalcaneal (TTC) arthrodesis is a salvage procedure for patients with severe osteoarthritis and other degenerative ankle conditions. Oftentimes, an intramedullary (IM) nail is implanted across the joints and then fixed with tibial and calcaneal screws. Maintaining compression and load sharing are both largely desired to promote fusion via primary bone healing; however, compression can be lost due to small amounts of bone resorption and IM nails are now being made from carbon-fiber epoxy to minimize stress shielding. To date, no one has been able to directly characterize or compare the specific amount of these parameters across nails in a single model. The purpose of this study is to compare influence of nail design and materials for compressive and load-sharing properties using a patient-specific finite-element model. Methods: A titanium nail, a pseudoelastic nickel-titanium nail, and carbon fiber-epoxy nail were investigated for (1) load sharing between the nail body and tibia under gait loading and (2) compression loss as a function of resorption in the talus. A patient- specific model of the ankle, both in geometry and material properties, was generated from a quantitative computed tomography (QCT) scan of a healthy leg. The models were segmented and meshed using SCANIP and exported into ABAQUS for finite- element analysis. Compression in the nickel-titanium nail was simulated by pre-stretching the pseudoelastic compressive element. Conversely, compression in the titanium and carbon-fiber nails were generated by giving the nail jacket an orthotropic contraction coefficient in the model. After compression was set, each nail was subjected to an applied gait load that peaked at 1121 N. Resorption was simulated using a thin compressible layer of bone in the talus and decreasing the modulus and Poisson’s ratio. Results: Surprisingly, the carbon-fiber nail showed similar stress shielding to the titanium nail, with 72% and 77% of the stress being transferred through the devices instead of the ankle, respectively. Even though carbon fiber-epoxy has a significantly lower modulus than titanium (75 GPa vs 110 GPa), the overall stiffness of the nails was still much greater than that of bone (~30,000 N/mm vs. ~44,000 N/mm vs. ~3,000 N/mm, respectively). The pseudoelastic nail only shielded 32% of the stress values by comparison. For the titanium and carbon-fiber nails, over 85% of the initial compression provided by the nail drops with 0.10 mm of resorption. The pseudoelastic nail maintained 90% of its initial compression after 0.10 mm of resorption. Conclusion: IM nail design and materials played a significant role in maintaining compression and load sharing. The pseudoelastic nail had the lowest degree of stress-shielding (32%) and maintained compression for over 0.10 mm of simulated resorption. Constant compression and the avoidance of “resorption gapping” is paramount to drive primary bone healing in joint fusions due to lack of periosteal/endosteal anatomy crossing the fusion site, thus impairing the ability for secondary bone healing (callus healing). This model allows for direct comparison between devices and can be used pre-operatively to predict patient-specific performance and help aid in device selection for TTC fusion

    Dissemination and Implementation of Shared Decision Making Into Clinical Practice: A Research Agenda.

    No full text
    Shared decision making (SDM) is essential to advancing patient-centered care in emergency medicine. Despite many documented benefits of SDM, prior research has demonstrated persistently low levels of patient engagement by clinicians across many disciplines, including emergency medicine. An effective dissemination and implementation (D&I) framework could be used to alter the process of delivering care and to facilitate SDM in routine clinical emergency medicine practice. Here we outline a research and policy agenda to support the D&I strategy needed to integrate SDM into emergency care

    Osteoarthritis Classification Scales: Interobserver Reliability and Arthroscopic Correlation

    No full text
    The MARS Group* Background: Osteoarthritis of the knee is commonly diagnosed and monitored with radiography. However, the reliability of radiographic classification systems for osteoarthritis and the correlation of these classifications with the actual degree of confirmed degeneration of the articular cartilage of the tibiofemoral joint have not been adequately studied. Methods: As the Multicenter ACL (anterior cruciate ligament) Revision Study (MARS) Group, we conducted a multicenter, prospective longitudinal cohort study of patients undergoing revision surgery after anterior cruciate ligament reconstruction. We followed 632 patients who underwent radiographic evaluation of the knee (an anteroposterior weight-bearing radiograph, a posteroanterior weight-bearing radiograph made with the knee in 45°of flexion [Rosenberg radiograph], or both) and arthroscopic evaluation of the articular surfaces. Three blinded examiners independently graded radiographic findings according to six commonly used systems-the Kellgren-Lawrence, International Knee Documentation Committee, Fairbank, Brandt et al., Ahlbäck, and Jäger-Wirth classifications. Interobserver reliability was assessed with use of the intraclass correlation coefficient. The association between radiographic classification and arthroscopic findings of tibiofemoral chondral disease was assessed with use of the Spearman correlation coefficient. Results: Overall, 45°posteroanterior flexion weight-bearing radiographs had higher interobserver reliability (intraclass correlation coefficient = 0.63; 95% confidence interval, 0.61 to 0.65) compared with anteroposterior radiographs (intraclass continue
    corecore