437 research outputs found

    Tibial tubercle osteotomy for access during revision knee arthroplasty: Ethibond suture repair technique

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Tibial Tubercle Osteotomy has shown much promise in revision total knee replacement. Methods of repair previously described include screw and wire fixation. Both methods have significant complications.</p> <p>Methods</p> <p>This article describes suture fixation of the osteotomy using Ethibond sutures placed medially with a lateral periosteal hinge.</p> <p>Results</p> <p>This method of fixation relies upon an adequate osteotomy segment including the entire insertion of the patella tendon. The lateral periosteal hinge is maintained and adds to the stability of the construct. A minimum of two number 5 Ethibond sutures are passed medially through drill holes to secure the osteotomy segment. No post-operative immobilisation is required.</p> <p>Conclusion</p> <p>Ethibond sutures provide adequate fixation of the tibial tubercle osteotomy segment in revision knee arthroplasty with reduced risk of complication as compared to conventional fixation methods.</p

    Less Anterior Knee Pain with a Mobile-bearing Prosthesis Compared with a Fixed-bearing Prosthesis

    Get PDF
    Anterior knee pain is one of the major short-term complaints after TKA. Since the introduction of the mobile-bearing TKA, numerous studies have attempted to confirm the theoretical advantages of a mobile-bearing TKA over a fixed-bearing TKA but most show little or no actual benefits. The concept of self-alignment for the mobile bearing suggests the posterior-stabilized mobile-bearing TKA would provide a lower incidence of anterior knee pain compared with a fixed-bearing TKA. We therefore asked whether the posterior-stabilized mobile-bearing knee would in fact reduce anterior knee pain. We randomized 103 patients scheduled for cemented three-component TKA for osteoarthrosis in a prospective, double-blind clinical trial. With a 1-year followup, more patients experienced persistent anterior knee pain in the posterior-stabilized fixed-bearing group (10 of 53, 18.9%) than in the posterior-stabilized mobile-bearing group (two of 47, 4.3%). No differences were observed for range of motion, visual analog scale for pain, Oxford 12-item questionnaire, SF-36, or the American Knee Society score. The posterior-stabilized mobile-bearing knee therefore seems to provide a short-term advantage compared with the posterior-stabilized fixed-bearing knee

    Influence of surgical approach on component positioning in primary total hip arthroplasty

    Get PDF
    Background: Minimal invasive surgery (MIS) has gained growing popularity in total hip arthroplasty (THA) but concerns exist regarding component malpositioning. The aim of the present study was to evaluate femoral and acetabular component positioning in primary cementless THA comparing a lateral to a MIS anterolateral approach. Methods: We evaluated 6 week postoperative radiographs of 52 hips with a minimal invasive anterolateral approach compared to 54 hips with a standard lateral approach. All hips had received the same type of implant for primary cementless unilateral THA and had a healthy hip contralaterally. Results: Hip offset was equally restored comparing both approaches. No influence of the approach was observed with regard to reconstruction of acetabular offset, femoral offset, vertical placement of the center of rotation, stem alignment and leg length discrepancy. However, with the MIS approach, a significantly higher percentage of cups (38.5 %) was malpositioned compared to the standard approach (16.7 %) (p = 0.022). Conclusions: The MIS anterolateral approach allows for comparable reconstruction of stem position, offset and center of rotation compared to the lateral approach. However, surgeons must be aware of a higher risk of cup malpositioning for inclination and anteversion using the MIS anterolateral approach

    The Elite-Plus stem migrates more than the flanged Charnley stem: A clinical, radiographic, and radiostereometric analysis of 114 patients with an average of 7 years follow-up

    Get PDF
    Background and purpose The Charnley Elite-Plus stem was introduced in 1993 as a presumed improvement of the flanged Charnley stem. We started this study in 1996 to investigate the migratory pattern of the Elite-Plus stem. Patients and methods We followed 114 patients with osteoarthritis and a primary total hip replacement with the Elite-Plus stem. Mean age at the time of operation was 64 (50-76) years. The mean follow-up time was 6.5 (2-7) years. Radiographs were evaluated with respect to cementing technique, migration, and wear measured by radiostereometry (RSA). Results The stem survival was 98% (CI: 96-100) at 7 years and 92% (CI: 86-97) at 10 years. Mean migration of the femoral head was 0.35 mm (SD 0.3) medially, 0.51 mm (SD 0.6) distally, and 1.1 mm (SD 1.8) in the dorsal direction. Mean total point motion was 1.7 mm (SD 1.7). The migration of the stems stabilized after 5 years in the medial and dorsal directions, but continued to subside slightly. Migration along any of the axes was higher if the cementing technique was inferior. Interpretation Patients with a Charnley Elite-Plus stem and defects in the cement mantle or other signs of inferior implantation technique should be carefully monitored

    Importance of Preoperative Imaging in Acetabular Revision Surgery - A Case Report

    Get PDF
    Acetabular defects, particularly as a result of protrusion of acetabular components into the hemipelvis, may cause serious complications during revision procedures as a result of iatrogenic injury to surrounding anatomical structures. In these challenging cases, we advocate the utilisation of preoperative three dimensional imaging. MRI and CT- imaging offer superior understanding of the three-dimensional quality of bony defects and the relationship of implants to important anatomical structures. Appropriate preoperative planning may also prevent major complications during the removal of the pre-existing hardware, prior to re-implantation of implants. Potential complications include injury of nerves, blood vessels and other intrapelvic structures

    Damages of the tibial post in constrained total knee prostheses in the early postoperative course – a scanning electron microscopic study of polyethylene inlays

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Investigation of the risk of fracture of the polyethylene (PE) inlay in constrained total knee prostheses.</p> <p>Methods</p> <p>Three unused and seven polyethylene inlays that had been implanted in a patient's knee for an average of 25.4 months (min 1.1 months, max 50.2 months) were investigated using scanning electron microscopy (SEM). All inlays were of the same type and size (Genesis II constrained, Smith & Nephew). The PE surface at the transition from the plateau to the post was analyzed.</p> <p>Results</p> <p>The unused inlays had fissure-free surfaces. All inlays that had been implanted in a patient's knee already had distinct fissures at the front and backside of the post.</p> <p>Conclusion</p> <p>The fissures of the transition from the plateau to the post indicated a loading-induced irreversible mechanical deformation and possibly cause the fracture of the inlay.</p

    Altered sensory-weighting mechanisms is observed in adolescents with idiopathic scoliosis

    Get PDF
    BACKGROUND: Scoliosis is the most common type of spinal deformity. In North American children, adolescent idiopathic scoliosis (AIS) makes up about 90% of all cases of scoliosis. While its prevalence is about 2% to 3% in children aged between 10 to 16 years, girls are more at risk than boys for severe progression with a ratio of 3.6 to 1. The aim of the present study was to test the hypothesis that idiopathic scoliosis interferes with the mechanisms responsible for sensory-reweighting during balance control. METHODS: Eight scoliosis patients (seven female and one male; mean age: 16.4 years) and nine healthy adolescents (average age 16.5 years) participated in the experiment. Visual and ankle proprioceptive information was perturbed (eyes closed and/or tendon vibration) suddenly and then returned to normal (eyes open and/or no tendon vibration). An AMTI force platform was used to compute centre of pressure root mean squared velocity and sway density curve. RESULTS: For the control condition (eyes open and no tendon vibration), adolescent idiopathic scoliosis patients had a greater centre of pressure root mean squared velocity (variability) than control participants. Reintegration of ankle proprioception, when vision was either available or removed, led to an increased centre of pressure velocity variability for the adolescent idiopathic scoliosis patients whereas the control participants reduced their centre of pressure velocity variability. Moreover, in the absence of vision, adolescent idiopathic scoliosis exhibited an increased centre of pressure velocity variability when ankle proprioception was returned to normal (i.e. tendon vibration stopped). The analysis of the sway density plot suggests that adolescent idiopathic scoliosis patients, during sensory reintegration, do not scale appropriately their balance control commands. CONCLUSION: Altogether, the present results demonstrate that idiopathic scoliosis adolescents have difficulty in reweighting sensory inputs following a brief period of sensory deprivation
    corecore