1,412 research outputs found
Charmonium Physics with PANDA at FAIR
One component of the future international Facility for Antiproton and Ion
Research - FAIR is directed towards studies of hadronic matter at the
sub-nuclear level with beams of antiprotons. These studies focus on two key
aspects: confinement of quarks and the generation of the hadron masses. These
goals will be pursued by performing precision measurements of charged and
neutral decay products from antiproton-proton annihilation in the charmonium
mass region. In this report an overview of the charmonium issues relevant to
PANDA will be presented.Comment: Contribution to the proceedings of HQL06, Munich, October 16th-20th
200
Studies of the effects of gravitational and inertial forces on cardiovascular and respiratory dynamics
The current status and application are described of the biplane video roentgen densitometry, videometry and video digitization systems. These techniques were developed, and continue to be developed for studies of the effects of gravitational and inertial forces on cardiovascular and respiratory dynamics in intact animals and man. Progress is reported in the field of lung dynamics and three-dimensional reconstruction of the dynamic thoracic contents from roentgen video images. It is anticipated that these data will provide added insight into the role of shape and internal spatial relationships (which is altered particularly by acceleration and position of the body) of these organs as an indication of their functional status
Application of the time-dependent charge asymmetry method for longitudinal position determination in prototype proportional chambers for the PANDA experiment
The PANDA collaboration intends to build a state-of-the-art detector to study
the physics of antiproton annihilation in the charm mass region at the future
FAIR facility at GSI, Darmstadt. One major part of the PANDA detector is the
straw tube tracker. It will consist of about 6000 individual straws grouped in
11 double layers and filled with an Ar+10%CO_2 gas mixture. The required radial
spatial resolution is about 150 micron. Two different methods are considered
for longitudinal coordinate measurements - skewed double layers and a novel
method based on the time-dependent charge asymmetry. The latter method is
presented in this article.Comment: 18 pages, 13 figures, Preprint submitted to NIM
Spatial imaging of modifications to fluorescence lifetime and intensity by individual Ag nanoparticles
Highly ordered periodic arrays of silver nanoparticles have been fabricated
which exhibit surface plasmon resonances in the visible spectrum. We
demonstrate the ability of these structures to alter the fluorescence
properties of vicinal dye molecules by providing an additional radiative decay
channel. Using fluorescence lifetime imaging microscopy (FLIM), we have created
high resolution spatial maps of the molecular lifetime components; these show
an order of magnitude increase in decay rate from a localized volume around the
nanoparticles, resulting in a commensurate enhancement in the fluorescence
emission intensity.Comment: 3 pages, 2 figures, submitted Applied Physics Letter
Plasmonic engineering of metal nanoparticles for enhanced fluorescence and Raman scattering
We have investigated the effects of tuning the localized surface plasmon
resonances (LSPRs) of silver nanoparticles on the fluorescence intensity,
lifetime, and Raman signal from nearby fluorophores. The presence of a metallic
structure can alter the optical properties of a molecule by increasing the
excitation field, and by modifying radiative and non-radiative decay
mechanisms. By careful choice of experimental parameters we have been able to
decouple these effects. We observe a four-fold increase in fluorescence
enhancement and an almost 30-fold increase in decay rate from arrays of Ag
nanoparticles, when the LSPR is tuned to the emission wavelength of a locally
situated fluorophore. This is consistent with a greatly increased efficiency
for energy transfer from fluorescence to surface plasmons. Additionally,
surface enhanced Raman scattering (SERS) measurements show a maximum
enhancement occurs when both the incident laser light and the Raman signal are
near resonance with the plasmon energy. Spatial mapping of the SERS signal from
a nanoparticle array reveals highly localized differences in the excitation
field resulting from small differences in the LSPR energy.Comment: Submitted to Plasmonics (Springer
Application of NASTRAN for stress analysis of left ventricle of the heart
Knowing the stress and strain distributions in the left ventricular wall of the heart is a prerequisite for the determination of the muscle elasticity and contractility in the process of assessing the functional status of the heart. NASTRAN was applied for the calculation of these stresses and strains and to help in verifying the results obtained by the computer program FEAMPS which was specifically designed for the plane-strain finite-element analysis of the left ventricular cross sections. Adopted for the analysis are the true shape and dimensions of the cross sections reconstructed from multiplanar X-ray views of a left ventricle which was surgically isolated from a dog's heart but metabolically supported to sustain its beating. A preprocessor was prepared to accommodate both FEAMPS and NASTRAN, and it has also facilitated the application of both the triangular element and isoparameteric quadrilateral element versions of NASTRAN. The stresses in several crucial regions of the left ventricular wall calculated by these two independently developed computer programs are found to be in good agreement. Such confirmation of the results is essential in the development of a method which assesses the heart performance
Empirical Parameterization of Nucleon-Nucleon Elastic Scattering Amplitude at High Beam Momenta for Glauber Calculations and Monte Carlo Simulations
A parameterization of the nucleon-nucleon elastic scattering amplitude is
needed for future experiments with nucleon and nuclear beams in the beam
momentum range of 2 -- 50 GeV/c/nucleon. There are many parameterizations of
the amplitude at 25--50 GeV/c, and at 5 GeV/c. Our
paper is aimed to cover the range between 5 -- 50 GeV/c.
The amplitude is used in Glauber calculations of various cross sections and
Monte Carlo simulations of nucleon-nucleon scatterings. Usually, the
differential nucleon-nucleon elastic scattering cross sections are described by
an exponential expression. Corresponding experimental data on interactions
at 0.005 (GeV/c) and 0.125 (GeV/c) have been fit. We
propose formulae to approximate the beam momentum dependence of these
parameters in the momentum range considered. The same was done for
interactions at 0.5 (GeV/c). Expressions for the momentum
dependence of the total and elastic cross sections, and the ratio of real to
imaginary parts of the amplitude at zero momentum transfer are also given for
and collisions. These results are sufficient for a first
approximation of the Glauber calculations. For more exact calculations we fit
the data at 0.005 (GeV/c) without restrictions on the maximum value
of using an expression based on two coherent exponential. The parameters
of the fits are found for the beam momentum range 2 -- 50 GeV/c.Comment: 14 pages, 10 figure
- …