36 research outputs found
歯科インプラント周囲の骨吸収に関する臨床疫学研究
Background: During functional loading, the design of the dental implant may have an effect on the response of marginal bone.
Objectives: The purpose of this study was to report the prevalence of peri-implantitis, and to compare radiographic parameters around Brånemark and Replace Select dental implants and evaluate whether disparities in the morphologic features of these two indistinct implant systems, particularly their abutment-implant attachment, had an influence on the health of surrounding tissues and marginal bone loss (MBL).
Materials and Methods: Collection of data was done at the Department of Fixed Prosthodontics, the Department of Maxillo-Facial Prosthodontics, and Oral Implant Center of Tokushima University Hospital, in Tokushima, Japan; between March 2003 and followed until January 2017. Patients who have been treated with the Replace Select internal type implant and the Brånemark variety were selected as cohort. Marginal bone level measurements were evaluated via periapical and panoramic radiographs taken at regular follow-up visit. These dimensions were calculated, starting from the orientation mark at the implant abutment interface to the bottommost perceived contact area of marginal bone with the aforementioned implant system. The change in the level of bone was estimated by calculating the variation involving an initial reference value and the follow-up values.
Results: An average loss of bone at 0.65 ± 1.51 mm (range 0.36 to 7.89 mm) in the Replace Select group was observed, while in the Brånemark group 0.7 ± 1.32 mm (range 0.62 to 8.64 mm) was observed. Spearman rank correlation exhibited a statistically significant positive correlation between progress of bone loss around implant body and interval from implantation in the Brånemark group, whereas in the Replace Select group it was not significant. The Brånemark group exhibited significant (P = 0.0269) negative correlation of MBL and its diameters, whereas the Replace Select group did not exhibit such correlation.
Conclusion: Within the limits of this study, it can be concluded that deviations in the morphologic attributes of these two diverse implant systems had an influence on the health of surrounding tissues and MBL. The Brånemark implants showed a significant increase in MBL (> 1.8mm) as the time of placement elapses. This marked MBL was greater in females than males, in posterior than in anterior, and in the narrow platform implants than the regular platform implants or the wide platform implants. On the other hand, results suggested that this bone loss was greater in the mandible than the maxilla, in single-unit implant crowns than multiple implant restorations in the Replace Select group
New Features on the Expression and Trafficking of mGluR1 Splice Variants Exposed by Two Novel Mutant Mouse Lines
Metabotropic glutamate receptors (mGluRs) couple to G-proteins to modulate slow synaptic transmission via intracellular second messengers. The first cloned mGluR, mGluR1, regulates motor coordination, synaptic plasticity and synapse elimination. mGluR1 undergoes alternative splicing giving rise to four translated variants that differ in their intracellular C-terminal domains. Our current knowledge about mGluR1 relates almost entirely to the long mGluR1α isoform, whereas little is known about the other shorter variants. To study the expression of mGluR1γ, we have generated by means of the CRISPR/Cas9 system a new knock-in (KI) mouse line in which the C-terminus of this variant carries two short tags. Using this mouse line, we could establish that mGluR1γ is either untranslated or in amounts that are undetectable in the mouse cerebellum, indicating that only mGluR1α and mGluR1β are present and active at cerebellar synapses. The trafficking and function of mGluR1 appear strongly influenced by adaptor proteins such as long Homers that bind to the C-terminus of mGluR1α. We generated a second transgenic (Tg) mouse line in which mGluR1α carries a point mutation in its Homer binding domain and studied whether disruption of this interaction influenced mGluR1 subcellular localization at cerebellar parallel fiber (PF)-Purkinje cell (PC) synapses by means of the freeze-fracture replica immunolabeling technique. These Tg animals did not show any overt behavioral phenotype, and despite the typical mGluR1 perisynaptic distribution was not significantly changed, we observed a higher probability of intrasynaptic diffusion suggesting that long Homers regulate the lateral mobility of mGluR1. We extended our ultrastructural analysis to other mouse lines in which only one mGluR1 variant was reintroduced in PC of mGluR1-knock out (KO) mice. This work revealed that mGluR1α preferentially accumulates closer to the edge of the postsynaptic density (PSD), whereas mGluR1β has a less pronounced perijunctional distribution and, in the absence of mGluR1α, its trafficking to the plasma membrane is impaired with an accumulation in intracellular organelles. In conclusion, our study sets several firm points on largely disputed matters, namely expression of mGluR1γ and role of the C-terminal domain of mGluR1 splice variants on their perisynaptic clustering
Improvement of the target sensitivity in DECIGO by optimizing its parameters for quantum noise including the effect of diffraction loss
DECIGO is the future Japanese gravitational wave detector in outer space. We
previously set the default design parameters to provide a good target
sensitivity to detect the primordial gravitational waves (GWs). However, the
updated upper limit of the primordial GWs by the Planck observations motivated
us for further optimization of the target sensitivity. Previously, we had not
considered optical diffraction loss due to the very long cavity length. In this
paper, we optimize various DECIGO parameters by maximizing the signal-to-noise
ratio (SNR), for the primordial GWs to quantum noise including the effects of
diffraction loss. We evaluated the power spectrum density for one cluster in
DECIGO utilizing the quantum noise of one differential Fabry-Perot
interferometer. Then we calculated the SNR by correlating two clusters in the
same position. We performed the optimization for two cases: the constant
mirror-thickness case and the constant mirror-mass case. As a result, we
obtained the SNR dependence on the mirror radius, which also determines various
DECIGO parameters. This result is the first step toward optimizing the DECIGO
design by considering the practical constraints on the mirror dimension and
implementing other noise sources.Comment: 13 pages, 12 figure
Current status of space gravitational wave antenna DECIGO and B-DECIGO
Deci-hertz Interferometer Gravitational Wave Observatory (DECIGO) is the
future Japanese space mission with a frequency band of 0.1 Hz to 10 Hz. DECIGO
aims at the detection of primordial gravitational waves, which could be
produced during the inflationary period right after the birth of the universe.
There are many other scientific objectives of DECIGO, including the direct
measurement of the acceleration of the expansion of the universe, and reliable
and accurate predictions of the timing and locations of neutron star/black hole
binary coalescences. DECIGO consists of four clusters of observatories placed
in the heliocentric orbit. Each cluster consists of three spacecraft, which
form three Fabry-Perot Michelson interferometers with an arm length of 1,000
km. Three clusters of DECIGO will be placed far from each other, and the fourth
cluster will be placed in the same position as one of the three clusters to
obtain the correlation signals for the detection of the primordial
gravitational waves. We plan to launch B-DECIGO, which is a scientific
pathfinder of DECIGO, before DECIGO in the 2030s to demonstrate the
technologies required for DECIGO, as well as to obtain fruitful scientific
results to further expand the multi-messenger astronomy.Comment: 10 pages, 3 figure
Current status of space gravitational wave antenna DECIGO and B-DECIGO
The Deci-hertz Interferometer Gravitational Wave Observatory (DECIGO) is a future Japanese space mission with a frequency band of 0.1 Hz to 10 Hz. DECIGO aims at the detection of primordial gravitational waves, which could have been produced during the inflationary period right after the birth of the Universe. There are many other scientific objectives of DECIGO, including the direct measurement of the acceleration of the expansion of the Universe, and reliable and accurate predictions of the timing and locations of neutron star/black hole binary coalescences. DECIGO consists of four clusters of observatories placed in heliocentric orbit. Each cluster consists of three spacecraft, which form three Fabry–Pérot Michelson interferometers with an arm length of 1000 km. Three DECIGO clusters will be placed far from each other, and the fourth will be placed in the same position as one of the other three to obtain correlation signals for the detection of primordial gravitational waves. We plan to launch B-DECIGO, which is a scientific pathfinder for DECIGO, before DECIGO in the 2030s to demonstrate the technologies required for DECIGO, as well as to obtain fruitful scientific results to further expand multi-messenger astronomy
2017~2019年度 関西大学研究拠点形成支援経費研究成果報告書
目次・研究成果の概要・2-1 工藤 宏人・宮前 翼・上田 正人・村山 憲弘・林 順一 "ノーリア骨格をテンプレートとした空孔内に水酸基を有する架橋化合物の合成とそれらの金属イオン包接性能" ネットワークポリマー論文集 vol.41, No.2, 65 - 71 (2020).・2-2 Mitsuaki Matsuoka, Kaho Yokoyama, Kohei Okura, Norihiro Murayama, Masato Ueda, Makio Naito " Synthesis of Geopolymers from Mechanically Activated Coal Fly Ash and Improvement of Their Mechanical Properties" Minerals 9, 791- 801 (2019).・2-3 Daisuke Shimoyama, Ryo Sekiya, Hiroto Kudo, Takeharu Haino, "Feet-to-Feet Connected Trisresorcinarenes" Organic Letters 22, 352 - 356 (2019).・2-4 Masato Ueda, Masahiko Ikeda, Shigeo Mori, Kenji Doi, Hisashi Kitagaki, Shuntaro Terauchi "Mechanical Properties of Additively Manufactured Porous Titanium with Sub-Millimetre Structural Units" Materials Transactions Vol.60, No.9, 1792 - 1798 (2019).・2-5 五十井 浩平・白杉 文香・松岡 光昭・林 順一・村山 憲弘 "種々のMg-Fe系複合酸化物を用いた希薄水溶液中のホウ素およびヒ素の除去" 環境資源工学 66, 29 - 35 (2019).・2-6 Toru Maruyama, Mitsuyoshi Tamaki, Keisuke Nakamura, Gou Nakamura "EFFECT OF MOLTEN METAL TEMPERATURE ON MOLD FILLING IN EVAPORATIVE PATTERN CASTING" International Journal of Metalcasting 13, 611–617 (2019).・2-7 Ryuta Saito, Toru Maruyama, Toshiki Nakamura, Hitoshi Yanagitani, Takahiro Sakai, Kouji Nakamoto "Influence of Tellurium Addition to Spheroidal Graphite Cast Iron on the Number of Graphite Particles" International Journal of Metalcasting Vol.13, 3, 571-577 (2018).・2-8 Masato Ueda, Rika Yamaguchi, Chika Fujita, Masahiko Ikeda "Control of Cell Adhesion on Titanium Dioxide by Light Irradiation" Materials Science Forum Vol.941, 2507 - 2512 (2018).・2-9 Hiroto Kudo, Mari Fukunaga, Kohei Shiotsuki, Hiroya Takeda, Hiroki Yamamoto, Takahiro Kozawa, Takeo Watanabe "Synthesis of hyperbranched polyacetals containing C-(4-t-butylbenz)calix[4]resorcinarene: Resist properties for extreme ultraviolet (EUV) lithography" Reactive and Functional Polymers 131, 361 - 367 (2018).・2-10 大隈 修・前 一廣・林 順一 "直接液化による豪州ビクトリア褐炭の高度利用 : 改新BCLプロセスによる化学原料の生産" Journal of the Japan Institute of Energy 98, 17 - 26 (2019).・2-11 Issei Suzuki, Ayako Kakinuma, Masato Ueda, Takahisa Omata "Flux growth of β-NaGaO₂ single crystals" Journal of Crystal Growth 504, 26 -30 (2018).・2-12 上田 正人、坂本 貴則、池田 勝彦 "電気抵抗率の精密測定による純チタンの組織評価" 環境資源工学 65, 74 -76 (2018).・2-13 Satoshi Imasaka, Hiroyasu Ishii, Jun\u27ichi Hayashi, Sadao Araki, Hideki Yamamoto "Synthesis of CHA-type titanosilicate zeolites using titanium oxide as Ti source and evaluation of their physicochemical properties" Microporous and Mesoporous Materials 273, 243-248 (2019).・2-14 Hiroto Kudo, Shizuya Ohori, Hiroya Takeda, Hiroki Ogawa, Takeo Watanbe, Hiroki Yamamoto, Takahiro Kozawa "Synthesis and Property of Tannic Acid Derivatives and Their Application for Extreme Ultraviolet Laser Lithography System" Journal of Photopolymer Science and Technology Vol.31, 221 - 225 (2018).・2-15 Hiroto Kudo, Tsubasa Miyamae, Kouta Kitagawa, Kohei Isoi, Norihiro Murayama, Jun\u27ichi Hayashi " Synthesis and Metal-Complexation Ability of Cross-Linking Materials Containing Noria-Templated Cavities with Pendant Carboxylic Acid Groups" Chemistry Select 3, 2223 - 2228 (2018).・2-16 上田 正人、池田 勝彦、土井 研児、 森 重雄、北垣 壽、寺内 俊太郎、関 あずさ "骨部分置換用ポーラスチタン : ポリグリコール酸 : 炭酸カルシウム複合体の開発" 高分子論文集 Vol.75, No.1, 69 - 74 (2018).・2-17 Alexandru C Sonoc, Jacob Jeswiet, Norihiro Murayama, Junji Shibata "A study of the application of Donnan dialysis to the recycling of lithium ion batteries" Hydrometallurgy 175, 133 - 143 (2018).2-3は、著作権の関係により非公開としております。2-8は、著作権の関係により非公開としております。2-9は、著作権の関係により非公開としております。2-10は、著作権の関係により非公開としております。2-11は、著作権の関係により非公開としております。2-16は、著作権の関係により非公開としております