7 research outputs found

    Mass Spectrometry as a Highly Sensitive Method for Specific Circulating Tumor DNA Analysis in NSCLC:A Comparison Study

    Get PDF
    Simple Summary We compared the UltraSEEK (TM) Lung Panel on the MassARRAY (R) System (Agena Bioscience) with the FDA-approved Cobas (R) EGFR Mutation Test v2 for the detection of EGFR mutations in liquid biopsies of NSCLC patients, accompanied with preanalytical sample assessment using the novel Liquid IQ (R) Panel. For the detection of relevant predictive mutations using the UltraSEEK (TM) Lung Panel, an input of over 10 ng showed 100% concordance with Cobas (R) EGFR Mutation Test v2 and detection of all tissue confirmed mutations. In case of lower ccfDNA input, the risk of missing clinically relevant mutations should be considered. The use of a preanalytical ccfDNA quality control assay such as the Liquid IQ (R) Panel is recommended to confidently interpret results, avoiding bias induced by non-specific genomic DNA and low input of specific tumoral ccfDNA fragments. Plasma-based tumor mutational profiling is arising as a reliable approach to detect primary and therapy-induced resistance mutations required for accurate treatment decision making. Here, we compared the FDA-approved Cobas (R) EGFR Mutation Test v2 with the UltraSEEK (TM) Lung Panel on the MassARRAY (R) System on detection of EGFR mutations, accompanied with preanalytical sample assessment using the novel Liquid IQ (R) Panel. 137 cancer patient-derived cell-free plasma samples were analyzed with the Cobas (R) and UltraSEEK (TM) tests. Liquid IQ (R) analysis was initially validated (n = 84) and used to determine ccfDNA input for all samples. Subsequently, Liquid IQ (R) results were applied to harmonize ccfDNA input for the Cobas (R) and UltraSEEK (TM) tests for 63 NSCLC patients. The overall concordance between the Cobas (R) and UltraSEEK (TM) tests was 86%. The Cobas (R) test detected more EGFR exon19 deletions and L858R mutations, while the UltraSEEK (TM) test detected more T790M mutations. A 100% concordance in both the clinical (n = 137) and harmonized (n = 63) cohorts was observed when >10 ng of ccfDNA was used as determined by the Liquid IQ (R) Panel. The Cobas (R) and UltraSEEK (TM) tests showed similar sensitivity in EGFR mutation detection, particularly when ccfDNA input was sufficient. It is recommended to preanalytically determine the ccfDNA concentration accurately to ensure sufficient input for reliable interpretation and treatment decision making

    Circulating tumor DNA as a biomarker for monitoring early treatment responses of patients with advanced lung adenocarcinoma receiving immune checkpoint inhibitors

    Get PDF
    Immunotherapy for metastasized non-small-cell lung cancer (NSCLC) can show long-lasting clinical responses. Selection of patients based on programmed death-ligand 1 (PD-L1) expression shows limited predictive value for durable clinical benefit (DCB). We investigated whether early treatment effects as measured by a change in circulating tumor DNA (ctDNA) level is a proxy of early tumor response to immunotherapy according to response evaluation criteria in solid tumors v1.1 criteria, progression-free survival (PFS), DCB, and overall survival (OS). To this aim, blood tubes were collected from advanced-stage lung adenocarcinoma patients (n = 100) receiving immune checkpoint inhibitors (ICI) at baseline (t(0)) and prior to first treatment evaluation (4-6 weeks; t(1)). Nontargetable (driver) mutations detected in the pretreatment tumor biopsy were used to quantify tumor-specific ctDNA levels using droplet digital PCR. We found that changes in ctDNA levels were strongly associated with tumor response. A > 30% decrease in ctDNA at t(1) correlated with a longer PFS and OS. In total, 80% of patients with a DCB of >= 26 weeks displayed a > 30% decrease in ctDNA levels. For patients with a PD-L1 tumor proportion score of >= 1%, decreasing ctDNA levels were associated with a higher frequency a DCB (80%) and a prolonged median PFS (85 weeks) and OS (101 weeks) compared with patients with no decrease in ctDNA (34%; 11 and 39 weeks, respectively). This study shows that monitoring of ctDNA dynamics is an easy-to-use and promising tool for assessing PFS, DCB, and OS for ICI-treated NSCLC patients

    The Presence of EGFR T790M in TKI-NaĂŻve Lung Cancer Samples of Patients Who Developed a T790M-Positive Relapse on First or Second Generation TKI Is Rare

    Get PDF
    EGFR-mutated non-small cell lung cancer (NSCLC) patients can be effectively treated with tyrosine kinase inhibitors (TKI) but frequently present with an EGFR T790M resistance mutation at relapse. We aimed to screen for T790M in pre-treatment formalin-fixed and paraffin-embedded (FFPE) tissue samples of patients with a confirmed T790M mutation at progression. We analyzed 33 pre-treatment DNA samples of NSCLC patients who progressed upon TKI between 2013 to 2019. To establish storage-time dependent formalin fixation-induced background levels for C>T mutations, we analyzed DNA isolated from archival (stored >1 year, n = 22) and recently generated (stored <1 month, n = 11) FFPE samples and included DNA isolated from white blood cells (WBC) (n = 24) as controls. DNA samples were analyzed by droplet digital (dd)PCR, and positivity was defined by outlier detection according to Grubb's criterion. The T790M background allele frequency levels were 0.160% in DNA isolated from archival-FFPE, 0.100% in fresh FFPE, and 0.035% in WBC. Progression-free survival (PFS) time of the single T790M positive patient was 9 months, while T790M negative patients had a median PFS of 10 months (range 2-27). Proper storage time matched FFPE control samples are essential for reliable detection of T790M mutation at low VAF. The presence of EGFR T790M mutations in pre-TKI samples is rare, even in patients who progressed with EGFR T790M mutations

    Detection and Monitoring of Tumor-Derived Mutations in Circulating Tumor DNA Using the UltraSEEK Lung Panel on the MassARRAY System in Metastatic Non-Small Cell Lung Cancer Patients

    Get PDF
    Analysis of circulating tumor DNA (ctDNA) is a potential minimally invasive molecular tool to guide treatment decision-making and disease monitoring. A suitable diagnostic-grade platform is required for the detection of tumor-specific mutations with high sensitivity in the circulating cell-free DNA (ccfDNA) of cancer patients. In this multicenter study, the ccfDNA of 72 patients treated for advanced-stage non-small cell lung cancer (NSCLC) was evaluated using the UltraSEEK ® Lung Panel on the MassARRAY ® System, covering 73 hotspot mutations in EGFR, KRAS, BRAF, ERBB2, and PIK3CA against mutation-specific droplet digital PCR (ddPCR) and routine tumor tissue NGS. Variant detection accuracy at primary diagnosis and during disease progression, and ctDNA dynamics as a marker of treatment efficacy, were analyzed. A multicenter evaluation using reference material demonstrated an overall detection rate of over 90% for variant allele frequencies (VAFs) &gt; 0.5%, irrespective of ccfDNA input. A comparison of UltraSEEK ® and ddPCR analyses revealed a 90% concordance. An 80% concordance between therapeutically targetable mutations detected in tumor tissue NGS and ccfDNA UltraSEEK ® analysis at baseline was observed. Nine of 84 (11%) tumor tissue mutations were not covered by UltraSEEK ®. A decrease in ctDNA levels at 4-6 weeks after treatment initiation detected with UltraSEEK ® correlated with prolonged median PFS (46 vs. 6 weeks; p &lt; 0.05) and OS (145 vs. 30 weeks; p &lt; 0.01). Using plasma-derived ccfDNA, the UltraSEEK ® Lung Panel with a mid-density set of the most common predictive markers for NSCLC is an alternative tool to detect mutations both at diagnosis and during disease progression and to monitor treatment response. </p

    Dutch National Round Robin Trial on Plasma-Derived Circulating Cell-Free DNA Extraction Methods Routinely Used in Clinical Pathology for Molecular Tumor Profiling

    Get PDF
    BACKGROUND: Efficient recovery of circulating tumor DNA (ctDNA) depends on the quantity and quality of circulating cell-free DNA (ccfDNA). Here, we evaluated whether various ccfDNA extraction methods routinely applied in Dutch laboratories affect ccfDNA yield, ccfDNA integrity, and mutant ctDNA detection, using identical lung cancer patient-derived plasma samples. METHODS: Aliquots of 4 high-volume diagnostic leukapheresis plasma samples and one artificial reference plasma sample with predetermined tumor-derived mutations were distributed among 14 Dutch laboratories. Extractions of ccfDNA were performed according to local routine standard operating procedures and were analyzed at a central reference laboratory for mutant detection and assessment of ccfDNA quantity and integrity. RESULTS: Mutant molecule levels in extracted ccfDNA samples varied considerably between laboratories, but there was no indication of consistent above or below average performance. Compared to silica membrane-based methods, samples extracted with magnetic beads-based kits revealed an overall lower total ccfDNA yield (-29%; P < 0.0001) and recovered fewer mutant molecules (-41%; P < 0.01). The variant allelic frequency and sample integrity were similar. In samples with a higher-than-average total ccfDNA yield, an augmented recovery of mutant molecules was observed. CONCLUSIONS: In the Netherlands, we encountered diversity in preanalytical workflows with potential consequences on mutant ctDNA detection in clinical practice. Silica membrane-based methodologies resulted in the highest total ccfDNA yield and are therefore preferred to detect low copy numbers of relevant mutations. Harmonization of the extraction workflow for accurate quantification and sensitive detection is required to prevent introduction of technical divergence in the preanalytical phase and reduce interlaboratory discrepancies

    Dutch National Round Robin Trial on Plasma-Derived Circulating Cell-Free DNA Extraction Methods Routinely Used in Clinical Pathology for Molecular Tumor Profiling

    No full text
    BACKGROUND: Efficient recovery of circulating tumor DNA (ctDNA) depends on the quantity and quality of circulating cell-free DNA (ccfDNA). Here, we evaluated whether various ccfDNA extraction methods routinely applied in Dutch laboratories affect ccfDNA yield, ccfDNA integrity, and mutant ctDNA detection, using identical lung cancer patient-derived plasma samples. METHODS: Aliquots of 4 high-volume diagnostic leukapheresis plasma samples and one artificial reference plasma sample with predetermined tumor-derived mutations were distributed among 14 Dutch laboratories. Extractions of ccfDNA were performed according to local routine standard operating procedures and were analyzed at a central reference laboratory for mutant detection and assessment of ccfDNA quantity and integrity. RESULTS: Mutant molecule levels in extracted ccfDNA samples varied considerably between laboratories, but there was no indication of consistent above or below average performance. Compared to silica membrane-based methods, samples extracted with magnetic beads-based kits revealed an overall lower total ccfDNA yield (-29%; P < 0.0001) and recovered fewer mutant molecules (-41%; P < 0.01). The variant allelic frequency and sample integrity were similar. In samples with a higher-than-average total ccfDNA yield, an augmented recovery of mutant molecules was observed. CONCLUSIONS: In the Netherlands, we encountered diversity in preanalytical workflows with potential consequences on mutant ctDNA detection in clinical practice. Silica membrane-based methodologies resulted in the highest total ccfDNA yield and are therefore preferred to detect low copy numbers of relevant mutations. Harmonization of the extraction workflow for accurate quantification and sensitive detection is required to prevent introduction of technical divergence in the preanalytical phase and reduce interlaboratory discrepancies
    corecore