3 research outputs found
Bubble formation during the collision of a sessile drop with a meniscus
The impact of a sessile droplet with a moving meniscus, as encountered in
processes such as dip-coating, generically leads to the entrapment of small air
bubbles. Here we experimentally study this process of bubble formation by
looking through the liquid using high-speed imaging. Our central finding is
that the size of the entrapped bubble crucially depends on the location where
coalescence between the drop and the moving meniscus is initiated: (i) at a
finite height above the substrate, or (ii) exactly at the contact line. In the
first case, we typically find bubble sizes of the order of a few microns,
independent of the size and speed of the impacting drop. By contrast, the
bubbles that are formed when coalescence starts at the contact line become
increasingly large, as the size or the velocity of the impacting drop is
increased. We show how these observations can be explained from a balance
between the lubrication pressure in the air layer and the capillary pressure of
the drop
Oblique drop impact onto a deep liquid pool
Oblique impact of drops onto a solid or liquid surface is frequently observed in nature. Most studies on drop impact and splashing, however, focus on perpendicular impact. Here we study oblique impact of 100μm drops onto a deep liquid pool, where we quantify the splashing threshold, maximum cavity dimensions and cavity collapse by high-speed imaging above and below the water surface. Gravity can be neglected in these experiments. Three different impact regimes are identified: smooth deposition onto the pool, splashing in the direction of impact only, and splashing in all directions. We provide scaling arguments that delineate these regimes by accounting for the drop impact angle and Weber number. The angle of the axis of the cavity created below the water surface follows the impact angle of the drop irrespectively of the Weber number, while the cavity depth and its displacement with respect to the impact position do depend on the Weber number. Weber number dependency of both the cavity depth and displacement is modeled using an energy argument
Oblique drop impact onto a deep liquid pool
\u3cp\u3eOblique impact of drops onto a solid or liquid surface is frequently observed in nature. Most studies on drop impact and splashing, however, focus on perpendicular impact. Here we study oblique impact of 100μm drops onto a deep liquid pool, where we quantify the splashing threshold, maximum cavity dimensions and cavity collapse by high-speed imaging above and below the water surface. Gravity can be neglected in these experiments. Three different impact regimes are identified: smooth deposition onto the pool, splashing in the direction of impact only, and splashing in all directions. We provide scaling arguments that delineate these regimes by accounting for the drop impact angle and Weber number. The angle of the axis of the cavity created below the water surface follows the impact angle of the drop irrespectively of the Weber number, while the cavity depth and its displacement with respect to the impact position do depend on the Weber number. Weber number dependency of both the cavity depth and displacement is modeled using an energy argument.\u3c/p\u3