3 research outputs found

    Absence of intraocular infections after hematopoietic stem cell transplantation at a single center: The experience with current preventive regimens

    Get PDF
    Purpose: To investigate the prevalence of intraocular infections after allogeneic stem cell transplantation (allo-SCT). Methods: The study design was a single institutional retrospective noncomparative cohort of 135 consecutive patients in 2006 and 2007 who underwent allo-SCT for hematological malignancy. The primary outcome wa

    Multicenter prospective validation study for international chronic ocular graft-versus-host disease consensus diagnostic criteria

    No full text
    © 2022Purpose: To validate the international chronic ocular graft-versus-host disease (GVHD) diagnostic criteria (ICCGVHD) compared to the National Institute of Health diagnostic criteria 2014 (NIH2014) for chronic ocular GVHD. Methods: Between 2013 and 2019, the study enrolled 233 patients with or without chronic ocular GVHD combined with the presence or absence of systemic chronic GVHD in an internationally prospective multicenter and observational cohort from 9 institutions. All patients were evaluated for four clinical parameters of ICCGVHD. Results: The relation between the ICCGVHD score (0-11) and NIH2014 eye score (0–4) was relatively high (r = 0.708, 95% CI: 0.637–0.767, p < 0.001). The sensitivity and specificity of ICCGVHD for NIH 2014 for 233 patients were 94.3% (95% CI: 89.6%–98.1%) and 71.7% (95% CI: 63.0–79.5%), respectively (cutoff value of the ICCGVHD score = 6). The positive predictive value was 77.1% (95% CI: 71.1%–82.1%), and the negative predictive value was 87.0% (95% CI:81.6–92.5%). For the patients with systemic GVHD (n = 171), the sensitivity and specificity were 94.2% and 67.2%, respectively (ICCGVHD-score cutoff value = 6). By receiver operating characteristic (ROC) curve analysis, the area under the curve (AUC) was 0.903 (95% CI: 0.859–0.948). For patients without systemic GVHD (n = 62), the sensitivity and specificity were 100% and 76.7%, respectively (ICCGVHD-score cutoff value = 6). The AUC was 0.891 (95% CI 0.673–1.000). Conclusions: Good sensitivity, specificity, predictive value and correlation were found between ICCGVHD and NIH2014. ICCGVHD scores ≥6 can be useful to diagnose ocular GVHD with or without systemic GVHD for clinical research.N
    corecore