    Implementing Wearable Sensors for Clinical Application at a Surgical Ward:Points to Consider before Starting

    Get PDF
    Incorporating technology into healthcare processes is necessary to ensure the availability of high-quality care in the future. Wearable sensors are an example of such technology that could decrease workload, enable early detection of patient deterioration, and support clinical decision making by healthcare professionals. These sensors unlock continuous monitoring of vital signs, such as heart rate, respiration rate, blood oxygen saturation, temperature, and physical activity. However, broad and successful application of wearable sensors on the surgical ward is currently lacking. This may be related to the complexity, especially when it comes to replacing manual measurements by healthcare professionals. This report provides practical guidance to support peers before starting with the clinical application of wearable sensors in the surgical ward. For this purpose, the Non-Adoption, Abandonment, Scale-up, Spread, and Sustainability (NASSS) framework of technology adoption and innovations in healthcare organizations is used, combining existing literature and our own experience in this field over the past years. Specifically, the relevant topics are discussed per domain, and key lessons are subsequently summarized.</p

    Determination of Changes in Tissue Perfusion at Home with Hyperspectral and Thermal Imaging in the First Six Weeks after Endovascular Therapy in Patients with Peripheral Arterial Disease

    Get PDF
    The aims of this study were to assess changes in tissue perfusion up to 6 weeks after endovascular therapy (EVT), in hospital and at home, and to determine differences in tissue perfusion between patients with and without clinical improvement or good angiographic result. This single-center prospective cohort study included patients undergoing EVT for Rutherford stages two to six. Hyperspectral and thermal imaging were performed at the dorsal and plantar sides of the foot. These measurements consisted of a baseline measurement pre-EVT, and six follow-up measurements obtained at 1 and 4 h and 6 weeks in hospital, and 1 day, 7 days, and 14 days at home. Clinical improvement was defined as a decrease of one or more Rutherford class or decrease in the wound surface area and a good angiographic result was accomplished when a Transatlantic Inter-Society Consensus for the Management of PAD II C or D lesion was treated and uninterrupted flow continued in at least one below-the-knee artery in continuation with the inframalleolar arteries. The study included 34 patients with 41 treated limbs. Deoxyhemoglobin values were lower 1 h post-EVT compared with baseline and increased over time up to 6 weeks post-EVT. Significant differences in deoxyhemoglobin levels at 7 and 14 days post-EVT were determined between patients with and without clinical or angiographic success. This prospective pilot study shows the feasibility of hyperspectral imaging and thermal imaging post-EVT at home, which may decrease the need for hospital visits

    Reliability assessment of hyperspectral imaging with the HyperView (TM) system for lower extremity superficial tissue oxygenation in young healthy volunteers

    Get PDF
    Purpose: Hyperspectral imaging (HSI) is a noninvasive spectroscopy technique for determining superficial tissue oxygenation. The HyperView™ system is a hand-held camera that enables perfusion image acquisition. The evaluation of superficial tissue oxygenation is warranted in the evaluation of patients with peripheral arterial disease. The aim was to determine the reliability of repeated HSI measurements. Methods: In this prospective cohort study, HSI was performed on 50 healthy volunteers with a mean age of 26.4 ± 2.5 years, at the lower extremity. Two independent observers performed HSI during two subsequent measurement sessions. Short term test–retest reliability and intra- and inter-observer reliability were determined, and generalizability and decision studies were performed. Transcutaneous oxygen pressure (TcPO2) measurements were also performed. Results: The short term test–retest reliability was good for the HSI values determined at the lower extremity, ranging from 0.72 to 0.90. Intra- and inter-observer reliability determined at different days were poor to moderate for both HSI (0.24 to 0.71 and 0.30 to 0.58, respectively) and TcPO2 (0.54 and 0.56, and 0.51 and 0.31, respectively). Reliability can be increased to >0.75 by averaging two measurements on different days. Conclusion: This study showed good short term test–retest reliability for HSI measurements, however low intra- and inter-observer reliability was observed for tissue oxygenation measurements with both HSI and TcPO2 performed at separate days in young healthy volunteers. Reliability of HSI can be improved when determined as a mean of two measurements taken on different days

    Detecting Changes in Tissue Perfusion With Hyperspectral Imaging and Thermal Imaging Following Endovascular Treatment for Peripheral Arterial Disease

    Get PDF
    PurposeHyperspectral imaging (HSI) and thermal imaging allow contact-free tissue perfusion measurements and may help determine the effect of endovascular treatment (EVT) in patients with peripheral arterial disease. This study aimed to detect changes in perfusion with HSI and thermal imaging peri-procedurally and determine whether these changes can identify limbs that show clinical improvement after 6 weeks.MethodsPatients with Rutherford class 2–6 scheduled for EVT were included prospectively. Hyperspectral imaging and thermal imaging were performed directly before and after EVT. Images were taken from the lateral side of the calves and plantar side of the feet. Concentrations of (de)oxyhemoglobin, oxygen saturation, and skin temperature were recorded. Angiographic results were determined on completion angiogram. Clinical improvement 6 weeks after EVT was defined as a decrease ≥ one Rutherford class. Peri-procedural changes in perfusion parameters were compared between limbs with and without good angiographic results or clinical improvement. To identify limbs with clinical improvement, receiver operating characteristic (ROC) curves were used to determine cutoff values for change in HSI.ResultsIncluded were 23 patients with 29 treated limbs. Change in HSI values and temperature was not significantly different between limbs with good and poor angiographic results. Change in peri-procedural deoxyhemoglobin, determined by HSI, at the calves and feet was significantly different between limbs with and without clinical improvement at 6 week follow-up (p=0.027 and p=0.017, respectively). The ROC curve for change in deoxyhemoglobin at the calves showed a cutoff value of ≤1.0, and ≤−0.5 at the feet, which were discriminative for clinical improvement (sensitivity 77%; specificity 75% and sensitivity 62%; specificity 88%, respectively).ConclusionsHSI can detect changes in perfusion at the calves after EVT in patients with Rutherford class 2–6. Peri-procedural deoxyhemoglobin changes at the calves and feet are significantly different between limbs with and without clinical improvement. Decrease in deoxyhemoglobin directly after EVT may identify limbs that show clinical improvement 6 weeks after EVT

    Laser Doppler Flowmetry Combined with Spectroscopy to Determine Peripheral Tissue Perfusion and Oxygen Saturation:A Pilot Study in Healthy Volunteers and Patients with Peripheral Arterial Disease

    Get PDF
    Background: In this study, we assessed the ability of the EPOS system (Perimed AB, Jarfalla, Stockholm, Sweden) to detect differences in tissue perfusion between healthy volunteers and patients with peripheral arterial disease (PAD) with different severity of disease. Methods: This singlecenter prospective pilot study included 10 healthy volunteers and 20 patients with PAD scheduled for endovascular therapy (EVT). EPOS measurements were performed at rest at 32 degrees C and 44 degrees C, followed by transcutaneous oxygen pressure (TcPo2) measurements. The measurements were performed on the dorsal and medial side of the foot, as well as the lateral side of the calf. EPOS parameters included hemoglobin oxygen saturation (HbSO(2)) and speed-resolved red blood cell (RBC) perfusion. Results: HbSO(2) at 44 degrees C was significantly different between the three groups for all measurement locations. The overall speed-resolved RBC perfusion at 44 degrees C was statistically significant between the groups on the dorsal and medial side of the foot but not on the calf. TcPO2 values were not significantly different between the three groups. Conclusions: This study demonstrates that the EPOS system can depict differences in tissue perfusion between healthy volunteers, patients with Fontaine class IIb PAD, and those with Fontaine class III or IV PAD but only after heating to 44 degrees C

    Supra- and Infra-Renal Aortic Neck Diameter Increase after Endovascular Repair of a Ruptured Abdominal Aortic Aneurysm

    Get PDF
    Hypovolemia-induced hypotension may lead to an aortic diameter decrease in patients with a ruptured abdominal aortic aneurysm (rAAA). This study investigates the changes in supra- and infra-renal aortic neck diameters before and after endovascular aortic aneurysm repair (EVAR) for rAAA and the possible association with endograft apposition. A retrospective cohort study was conducted including 74 patients treated between 2010 and 2019 in two large European vascular centers. Outer-to-outer wall diameters were measured at +40, +10, 0, −10, and −20 mm relative to the lowest renal artery baseline on the last pre- and first post-EVAR computed tomography angiography (CTA) scan in a vascular workstation. Endograft apposition was determined on the first post-EVAR CTA scan. The post-operative diameter was significantly (p < 0.001) larger than the preoperative diameter at all aortic levels. The aortic diameter at +40 mm (supra-renal) and −10 mm (infra-renal) increased by 6.2 ± 7.3% and 12.6 ± 9.8%, respectively. The aortic diameter at +40 mm increased significantly more in patients with low preoperative systolic blood pressure (<90 mmHg; p = 0.005). A shorter apposition length was associated with a higher aortic diameter increase (R = −0.255; p = 0.032). Hypovolemic-induced hypotension results in a significant decrease in the aortic diameter in patients with an rAAA, which should be taken into account when oversizing the endograft

    Telemedicine in patients with peripheral arterial disease:is it worth the effort?

    Get PDF
    Introduction: For patients with peripheral arterial disease (PAD), the various components of telemedicine, such as telemonitoring, telecoaching, and teleconsultation, could be valuable in daily management. The objective of this review was to give an overview of the current use of telemedicine interventions in PAD. Areas covered: A literature search was performed for studies that evaluated patients with PAD of the aorto-pedal trajectory, who were monitored by telemedicine and acted upon accordingly. The primary outcome was health-related outcomes. The studies that were found focused mainly on wearable activity monitoring and telecoaching in PAD (n = 4) or wound monitoring after vascular surgery (n = 2). Main results indicate that telemedicine interventions are able to detect (post-operative) complications early, improve functional capacity and claudication onset time, and improve PAD patients' quality of life. Expert opinion: The use of telemedicine in PAD patients is still an under-explored area. Studies investigating the use of telemedicine in PAD are very limited and show varying results. Owing to its high potential in improving physical ability, lifestyle coaching, and timely detection of deterioration, future research should focus on proper implementation of telemedicine in PAD patients, including clinical and feasibility outcomes, effect on workload of nurses, and cost-efficiency

    Validation of a Length-Adjusted Abdominal Arterial Calcium Score Method for Contrast-Enhanced CT Scans

    Get PDF
    BACKGROUND: The Agatston score on noncontrast computed tomography (CT) scans is the gold standard for calcium load determination. However, contrast-enhanced CT is commonly used for patients with atherosclerotic cardiovascular diseases (ASCVDs), such as peripheral arterial occlusive disease (PAOD) and abdominal aortic aneurysm (AAA). Currently, there is no validated method to determine calcium load in the aorta and peripheral arteries with a contrast-enhanced CT. This study validated a length-adjusted calcium score (LACS) method for contrast-enhanced CT scans.METHOD: The LACS (calcium volume in mm 3/arterial length in cm) in the abdominal aorta was calculated using four-phase liver CT scans of 30 patients treated between 2017 and 2021 at the University Medical Center Groningen (UMCG) with no aortic disease. Noncontrast CT scans were segmented with a 130 Hounsfield units (HU) threshold, and a patient-specific threshold was used for contrast-enhanced CTs. The LACS was calculated and compared from both segmentations. Secondly, the interobserver variability and the influence of slice thickness (0.75 mm vs. 2.0 mm) was determined. RESULTS: There was a high correlation between the LACS from contrast-enhanced CT scans and the LACS of noncontrast CTs ( R 2 = 0.98). A correction factor of 1.9 was established to convert the LACS derived from contrast-enhanced CT to noncontrast CT scans. LACS interobserver agreement on contrast-enhanced CT was excellent (1.0, 95% confidence interval = 1.0-1.0). The 0.75 mm CT threshold was 541 (459-625) HU compared with 500 (419-568) HU on 2 mm CTs ( p = 0.15). LACS calculated with both thresholds was not significantly different ( p = 0.63). CONCLUSION: The LACS seems to be a robust method for scoring calcium load on contrast-enhanced CT scans in arterial segments with various lengths.</p

    Remodeling of Abdominal Aortic Angulation and Curvature After Endovascular Aneurysm Repair in Patients With vs Without Late Type Ia Endoleak or Endograft Migration

    Get PDF
    Purpose: To investigate aortic remodeling of the supra- and infrarenal aorta from preoperative to 1 month and midterm follow-up after endovascular aneurysm repair (EVAR) by analyzing changes in angulation and curvature in patients with vs without late type Ia endoleak or device migration. Materials and Methods: From a multicenter database, 35 patients (mean age 76 +/- 5 years; 31 men) were identified with late (>1 year) type Ia endoleak or endograft migration (>= 10 mm) and defined as the complication group. The control group consisted of 53 patients (mean age 75 +/- 7 years; 48 men) with >1-year computed tomography angiography (CTA) follow-up and no evidence of endoleaks. Suprarenal and infrarenal angles were measured on centerline reconstructions of the preoperative, 1-month, and midterm CTA scans. The value and location relative to baseline of maximum suprarenal and infrarenal curvature were determined semiautomatically using dedicated software. Changes were determined at 1 month compared with the preoperative CTA and at midterm compared with 1 month. Results: Preoperative suprarenal angulation was significantly greater in the complication group compared to the controls (34 degrees +/- 18 degrees vs 24 degrees +/- 17 degrees, p=0.008). It decreased significantly at 1 month in the complication group (29 degrees +/- 16 degrees, p=0.011) and at midterm follow-up in the controls (20 degrees +/- 19 degrees, p Conclusion: At midterm follow-up, significant differences in supra- and infrarenal angulation and curvature were observed between patients with vs without type Ia endoleak or migration. The location of the maximum curvature shifted distally in patients with complications. The aortic morphology is more stable during midterm follow-up in the patients without endoleaks

    Changes in Apposition of Endograft Limbs in the Iliac Arteries After Endovascular Aneurysm Repair:Determination With New Computed Tomography-Applied Software

    Get PDF
    Purpose: To validate new computed tomography (CT)-applied software used to determine endograft limb position and apposition after endovascular aneurysm repair (EVAR). Materials and Methods: Twelve EVAR patients (mean age 81 +/- 6 years; 10 men) with distal stent-graft extensions for 15 (3 bilateral) type Ib endoleaks during follow-up were selected based on the availability of the following CT studies: pre-EVAR, 1 month, and the penultimate scan prior to the scan disclosing the type Ib endoleak. Twelve patients (mean age 82 +/- 7 years; 11 men) without endoleak and a similar interval between the primary EVAR procedure and the penultimate CT scan of the endoleak group were selected as controls using measurements from both endograft limbs (n=21, 3 excluded). Prototype Vascular Imaging Analysis software was adapted to calculate 6 parameters for the distal apposition zone: fabric distance, shortest apposition length, endograft diameter, iliac seal surface (ISS), iliac endograft apposition surface (IEAS), and percentage of iliac surface coverage (IEAS/ISS x 100). Measurements were performed on the preoperative, first postoperative, and penultimate/matched follow-up CT scans. Interobserver variability was assessed with the intraclass correlation coefficient (ICC). Continuous data are presented as the median [interquartile range (IQR) Q1, Q3]. Results: CTA follow-up was not significantly different between the endoleak and control groups [30 months (IQR 18, 58) vs 36 months (IQR 21, 59), p=0.843]. Interobserver agreement was good to excellent for all parameters (ICC 0.879-0.985). Preoperative anatomy and endograft dimensions on the first follow-up CTA scan did not differ significantly between the groups. When the penultimate CTA scan was compared with the first postoperative CT scan, endograft dimensions had significantly changed in the endoleak group; importantly, apposition was significantly decreased, and fabric distance was significantly increased, indicating limb retraction. Differences in changes in endograft dimensions were significant between the groups. Conclusion: New CT-applied software was introduced to visualize apposition and position changes of endograft limbs during follow-up. The software demonstrated good-to-excellent interobserver agreement and enabled accurate analysis of post-EVAR endograft dimensions. Significant changes in apposition and position were observed with the software on the penultimate CT scan prior to diagnosis of type Ib endoleak