84 research outputs found

    A case report of an interrupted inferior vena cava and azygos continuation:Implications for preoperative screening in minimally invasive cardiac surgery

    Get PDF
    Background: Femoral cannulation is commonly used in minimally invasive cardiac surgery to establish extracorporeal circulation. We present a case with a finding that should be evaluated when screening candidates for minimally invasive cardiac surgery. Case summary: A 57-year-old male patient was scheduled for minimally invasive repair of the mitral and tricuspid valve and a MAZE procedure. During surgery there was difficulty advancing the venous cannula inserted in the right femoral vein. On transoesophageal echocardiography a guidewire advanced from the femoral vein was observed entering the right atrium from the superior vena cava. Despite inserting a second venous cannula in the jugular vein, venous drainage was insufficient for minimal invasive surgery. The approach was converted to a median sternotomy with bicaval cannulation. Re-examination of the preoperative computed tomography (CT) scan showed an interrupted inferior vena cava (IVC) with azygos continuation. Discussion: In patients with major venous malformations such as the interrupted IVC with azygos continuation a full sternotomy is the preferred approach. The venous system should be evaluated when screening candidates for minimally invasive mitral valve surgery with preoperative CT. Additional cues to suspect interruption of the IVC are polysplenia and a broad superior mediastinal projection on the chest radiograph, mimicking a right paratracheal mass.</p

    Change in Androgenic Status and Cardiometabolic Profile of Middle-Aged Women with Polycystic Ovary Syndrome

    Get PDF
    Understanding the cardiovascular disease (CVD) risk for women with polycystic ovary syndrome (PCOS) at reproductive age is crucial. To investigate this, we compared the cardiometabolic profiles of different PCOS groups over a median interval of 15.8 years. The study focused on three groups: (1) women with PCOS who were hyperandrogenic at both initial and follow-up screening (HA-HA), (2) those who transitioned from hyperandrogenic to normoandrogenic (HA-NA), and (3) those who remained normoandrogenic (NA-NA). At initial and follow-up screenings, both HA-HA and HA-NA groups showed higher body mass indexes compared to the NA-NA group. Additionally, at follow-up, the HA-HA and HA-NA groups exhibited higher blood pressure, a higher prevalence of hypertension, elevated serum triglycerides and insulin levels, and lower levels of HDL cholesterol compared to the NA-NA group. Even after adjusting for BMI, significant differences persisted in HDL cholesterol levels and hypertension prevalence among the groups (HA-HA: 53.8%, HA-NA: 53.1%, NA-NA: 14.3%, p &lt; 0.01). However, calcium scores and the prevalence of coronary plaques on CT scans were similar across all groups. In conclusion, women with PCOS and hyperandrogenism during their reproductive years exhibited an unfavorable cardiometabolic profile during their post-reproductive years, even if they changed to a normoandrogenic status.</p

    Undetectable High-Sensitivity Troponin T as a Gatekeeper for Coronary Computed Tomography Angiography in Patients Suspected of Acute Coronary Syndrome

    Get PDF
    OBJECTIVES: The aim of this study was to characterize the safety and efficiency of a strategy employing the limit of detection (LoD) of high-sensitivity troponin T (hs-TnT) as a gatekeeper for coronary computed tomography angiography (CCTA) in suspected acute coronary syndrome (ACS) patients in the emergency department (ED). METHODS: We included suspected ACS patients who underwent CCTA and were evaluated with hs-TnT. Patients were categorized as below the LoD and at or above the LoD. The primary outcome was 30-day major adverse cardiac events (MACEs), defined as all-cause mortality, ACS, or coronary revascularization. RESULTS: The study population consisted of 177 patients (mean age 55 ± 10 years, 50.3% women), and 16 (9.0%) patients reached the primary outcome. None of the patients died, while 13 had an adjudicated diagnosis of ACS, and 3 underwent elective coronary revascularization. There were 77 patients (44%) with an hs-TnT value below the LoD (MACEs; n = 1 [1.3%]) and 100 (56%) with at or above the LoD levels (MACEs; n = 15 [15%]). None of 67 patients with an hs-TnT value below the LoD and <50% stenosis on CCTA experienced MACEs. Out of the 10 patients with an hs-TnT value below the LoD and ≥50% stenosis on CCTA, 1 patient underwent elective percutaneous coronary revascularization. In patients with an hs-TnT value at or above the LoD, 74 patients had <50% stenosis on CCTA, and 2 patients (3%) were diagnosed with myocardial infarction without obstructive coronary artery disease confirmed on invasive angiography. Thirteen (50%) patients with an hs-TnT value at or above the LoD and ≥50% stenosis on CCTA experienced MACEs (11 ACS and 2 elective percutaneous coronary revascularizations). CONCLUSION: Our findings support that implementing the LoD of hs-TnT as a gatekeeper may reduce the need for CCTA in suspected ACS patients in the ED

    Preoperative Chest Computed Tomography Screening for Coronavirus Disease 2019 in Asymptomatic Patients Undergoing Cardiac Surgery

    Get PDF
    Due to the outbreak of Severe Acute Respiratory Syndrome coronavirus (SARS-Cov-2), an efficient COVID-19 screening strategy is required for patients undergoing cardiac surgery. The objective of this prospective observational study was to evaluate the role of preoperative computed tomography (CT) screening for COVID-19 in a population of COVID-19 asymptomatic patients scheduled for cardiac surgery. Between the 29th of March and the 26th of May 2020, patients asymptomatic for COVID-19 underwent a CT-scan the day before surgery, with reverse-transcriptase polymerase-chain reaction (RT-PCR) reserved for abnormal scan results. The primary endpoint was the prevalence of abnormal scans, which was evaluated using the CO-RADS score, a COVID-19 specific grading system. In a secondary analysis, the rate of abnormal scans was compared between the screening cohort and matched historical controls who underwent routine preoperative CT-screening prior to the SARS-Cov-2 outbreak. Of the 109 patients that underwent CT-screening, an abnormal scan result was observed in 7.3% (95% confidence interval: 3.2–14.0%). One patient, with a normal screening CT, was tested positive for COVID-19, with the first positive RT-PCR on the ninth day after surgery. A rate of preoperative CT-scan abnormalities of 8% (n = 8) was found in the unexposed historical controls (P &gt; 0.999). In asymptomatic patients undergoing cardiac surgery, preoperative screening for COVID-19 using computed tomography will identify pulmonary abnormalities in a small percentage of patients that do not seem to have COVID-19. Depending on the prevalence of COVID-19, this results in an unfavorable positive predictive value of CT screening. Care should be taken when considering CT as a screening tool prior to cardiac surgery.</p

    Clinical outcome of anomalous coronary artery with interarterial course in adults:Single-center experience combined with a systematic review

    Get PDF
    Background: Anomalous coronary artery originating from the opposite sinus of Vasalva with interarterial course (ACAOS-IAC) is associated with sudden cardiac death (SCD) in young athletes. If identified in adulthood prognosis is usually more benign, resulting in a dilemma regarding revascularization. Methods: This is a retrospective observational single-center study, including adults with ACAOS-IAC. Medical records between 2012 and 2019 were reviewed for management approach, mortality, cardiac death and coronary related adverse events. Coronary computed tomographic angiography (CCTA) were reviewed. We provide a literature review in regard to clinical outcome. Results: We identified 40 patients with ACAOS-IAC (mean age 51). Presentation was acute in 7/40 (18%). Ischemia detection with single photon emission tomography (SPECT), cardiac magnetic resonance (CMR) or dobutamine stress echocardiography were performed in 25/40 (63%) patients. Ischemia in the vascular territory of the anomaly was present in 2/25 (8%). In 39/40 (98%) patients were treated expectative. During median follow-up of 2.7 years (IQR 1.5–5.3) no cardiovascular death was observed. Mortality occurred in 1/40 (3%) and coronary related adverse events in 2/40 (5%). We identified 20 studies describing 1194 patients. Revascularization was performed in 376/1154 (32.6%) patients. Mortality stratified for clinical management was 23/431 (5.3%) in the non-revascularization versus 16/253 (6.3%) in the revascularization group during 4.0 years follow-up (weighted median). Cause of death was cardiovascular in 10/596 (1.7%) in 4.2 years (weighted median) follow up. Conclusions: Both revascularization and non-invasive management have good prognosis in adults with ACAOS-IAC during early follow up. There is need for guidelines and long-term surveillance.</p

    Radiation dose optimization for photon-counting CT coronary artery calcium scoring for different patient sizes:a dynamic phantom study

    Get PDF
    Purpose: To systematically assess the radiation dose reduction potential of coronary artery calcium (CAC) assessments with photon-counting computed tomography (PCCT) by changing the tube potential for different patient sizes with a dynamic phantom. Methods: A hollow artery, containing three calcifications of different densities, was translated at velocities corresponding to 0, &lt; 60, 60–75, and &gt; 75 beats per minute within an anthropomorphic phantom. Extension rings were used to simulate average- and large -sized patients. PCCT scans were made with the reference clinical protocol (tube potential of 120 kilovolt (kV)), and with 70, 90, Sn100, Sn140, and 140 kV at identical image quality levels. All acquisitions were reconstructed at a virtual monoenergetic energy level of 70 keV. For each calcification, Agatston scores and contrast-to-noise ratios (CNR) were determined, and compared to the reference with Wilcoxon signed-rank tests, with p &lt; 0.05 indicating significant differences. Results: A decrease in radiation dose (22%) was achieved at Sn100 kV for the average-sized phantom. For the large phantom, Sn100 and Sn140 kV resulted in a decrease in radiation doses of 19% and 3%, respectively. Irrespective of CAC density, Sn100 and 140 kVp did not result in significantly different CNR. Only at Sn100 kV were there no significant differences in Agatston scores for all CAC densities, heart rates, and phantom sizes. Conclusion: PCCT at tube voltage of 100 kV with added tin filtration and reconstructed at 70 keV enables a ≥ 19% dose reduction compared to 120 kV, independent of phantom size, CAC density, and heart rate. Key Points: • Photon-counting CT allows for reduced radiation dose acquisitions (up to 19%) for coronary calcium assessment by reducing tube voltage while reconstructing at a normal monoE level of 70 keV. • Tube voltage reduction is possible for medium and large patient sizes, without affecting the Agatston score outcome.</p

    Radiation dose optimization for photon-counting CT coronary artery calcium scoring for different patient sizes:a dynamic phantom study

    Get PDF
    PURPOSE: To systematically assess the radiation dose reduction potential of coronary artery calcium (CAC) assessments with photon-counting computed tomography (PCCT) by changing the tube potential for different patient sizes with a dynamic phantom.METHODS: A hollow artery, containing three calcifications of different densities, was translated at velocities corresponding to 0, &lt; 60, 60-75, and &gt; 75 beats per minute within an anthropomorphic phantom. Extension rings were used to simulate average- and large -sized patients. PCCT scans were made with the reference clinical protocol (tube potential of 120 kilovolt (kV)), and with 70, 90, Sn100, Sn140, and 140 kV at identical image quality levels. All acquisitions were reconstructed at a virtual monoenergetic energy level of 70 keV. For each calcification, Agatston scores and contrast-to-noise ratios (CNR) were determined, and compared to the reference with Wilcoxon signed-rank tests, with p &lt; 0.05 indicating significant differences.RESULTS: A decrease in radiation dose (22%) was achieved at Sn100 kV for the average-sized phantom. For the large phantom, Sn100 and Sn140 kV resulted in a decrease in radiation doses of 19% and 3%, respectively. Irrespective of CAC density, Sn100 and 140 kVp did not result in significantly different CNR. Only at Sn100 kV were there no significant differences in Agatston scores for all CAC densities, heart rates, and phantom sizes.CONCLUSION: PCCT at tube voltage of 100 kV with added tin filtration and reconstructed at 70 keV enables a ≥ 19% dose reduction compared to 120 kV, independent of phantom size, CAC density, and heart rate.KEY POINTS: • Photon-counting CT allows for reduced radiation dose acquisitions (up to 19%) for coronary calcium assessment by reducing tube voltage while reconstructing at a normal monoE level of 70 keV. • Tube voltage reduction is possible for medium and large patient sizes, without affecting the Agatston score outcome.</p
    • …
    corecore