392 research outputs found

    Design Concepts and Process Analysis for Transmuter Fuel Manufacturing: Quarterly Progress Report #2

    Full text link
    This report discusses mainly the fabrication of inert matrix fuels. There are three fabrication routes to obtain inert matrix fuels (IMF). IMF is a dispersion-type fuel in which the actinide phase is distributed as a separate phase in a so called inert matrix. This concept has evolved as one of the most promising in the field of transmutation. The following section discusses each manufacturing route aside

    Analysis of some recharge solutions on varying the R407C composition

    Get PDF
    In the vapour compression plants possible leaks can vary the composition of a zeotropic refrigerant mixture. The main aim of this paper is to verify experimentally if the plant performances are restored with a proper recharge, when leaks are imposed. As for the R407C mixture the percentage of the less volatile component (R134a) increases, while the percentage of the more volatile components (R32 and R125) decreases when leaks occur. The experimental tests have been realized determining refrigerant leaks from the liquid receiver placed at the condenser outlet and measuring the properties in steady state condition. The recharge is realized in different ways: with R407C, with R134a and R410A or with R32 R125 and R134a. The different solutions are then compared from the economical point of view, in terms of COP, refrigeration power and air temperature at the evaporator outlet, adopting an iteration method. This method determines the real composition of a zeotropic mixture working in a compression plant, when only the temperature and pressure values at the expansion valve inlet and outlet are known

    Refrigeration plant exergetic analysis varying the compressor capacity

    Get PDF
    The paper presents an exergetic analysis of a vapour compressor refrigeration plant when the refrigeration capacity is controlled by varying the compressor speed. The aim is performance evaluation of both the whole plant and its individual components. The analysis of the exergy flow destroyed in each device of the plant varying the compressor speed has been carried out in order to determine the relative irreversibility of the plant components. The vapour compression plant is subjected to a commercially available cold store. The compressor working with R22, R407C and R507 and designed for a revolution speed corresponding to 50 Hz supply current frequency, has been used varying the frequency in the range 30–50 Hz. In this range, the most suitable working fluids proposed as substitutes of R22, as R407C (R32/R125/R134a 23/25/52% in mass), R507 (R125/R143A 50/50% in mass) and R417A (R125/R134a/R600 46.6/50/3.4% in mass), have been tested. The variable-speed compressor is fitted with a pulse-width modulated source inverter (PWM) predominantly used in medium power applications due to its relatively low cost and high efficiency. The basic difference between variable speed refrigeration and conventional refrigeration systems is in the control of the system capacity at part-load conditions. The conventional refrigeration systems are characterized by compressor on/off cycles arising from by the thermostatic control. On the contrary when the inverter is used the capacity of the refrigeration system is matched to the load regulating the compressor motor speed. When the control of the compressor capacity is obtained by varying its speed there is an energy saving with respect to the thermostatic control. The best results of the exergetic analysis have been obtained using R22 followed by the non-azeotropic mixture designed as R407C that confirms, among the fluid candidates R22 substitution a better performance, shown also at the compressor nominal speed. Copyright © 2003 John Wiley & Sons, Ltd

    Refrigeration plant exergetic analysis varying the compressor capacity

    Get PDF
    The paper presents an exergetic analysis of a vapour compressor refrigeration plant when the refrigeration capacity is controlled by varying the compressor speed. The aim is performance evaluation of both the whole plant and its individual components. The analysis of the exergy flow destroyed in each device of the plant varying the compressor speed has been carried out in order to determine the relative irreversibility of the plant components. The vapour compression plant is subjected to a commercially available cold store. The compressor working with R22, R407C and R507 and designed for a revolution speed corresponding to 50 Hz supply current frequency, has been used varying the frequency in the range 30–50 Hz. In this range, the most suitable working fluids proposed as substitutes of R22, as R407C (R32/R125/R134a 23/25/52% in mass), R507 (R125/R143A 50/50% in mass) and R417A (R125/R134a/R600 46.6/50/3.4% in mass), have been tested. The variable-speed compressor is fitted with a pulse-width modulated source inverter (PWM) predominantly used in medium power applications due to its relatively low cost and high efficiency. The basic difference between variable speed refrigeration and conventional refrigeration systems is in the control of the system capacity at part-load conditions. The conventional refrigeration systems are characterized by compressor on/off cycles arising from by the thermostatic control. On the contrary when the inverter is used the capacity of the refrigeration system is matched to the load regulating the compressor motor speed. When the control of the compressor capacity is obtained by varying its speed there is an energy saving with respect to the thermostatic control. The best results of the exergetic analysis have been obtained using R22 followed by the non-azeotropic mixture designed as R407C that confirms, among the fluid candidates R22 substitution a better performance, shown also at the compressor nominal speed

    A miniature sensor for electrical field measurements in dusty planetary atmospheres

    Full text link
    "Dusty phenomena such as regular wind-blown dust, dust storms, and dust devils are the most important, currently active, geological processes on Mars. Electric fields larger than 100 kV/m have been measured in terrestrial dusty phenomena. Theoretical calculations predict that, close to the surface, the bulk electric fields in martian dusty phenomena reach the breakdown value of the isolating properties of thin martian air of about a few 10 kV/m. The fact that martian dusty phenomena are electrically active has important implications for dust lifting and atmospheric chemistry. Electric field sensors are usually grounded and distort the electric fields in their vicinity. Grounded sensors also produce large errors when subject to ion currents or impacts from clouds of charged particles. Moreover, they are incapable of providing information about the direction of the electric field, an important quantity. Finally, typical sensors with more than 10 cm of diameter are not capable of measuring electric fields at distances as small as a few cm from the surface. Measurements this close to the surface are necessary for studies of the effects of electric fields on dust lifting. To overcome these shortcomings, we developed the miniature electric-field sensor described in this article."http://deepblue.lib.umich.edu/bitstream/2027.42/64202/1/jpconf8_142_012075.pd

    Electrostatics in wind-blown sand

    Full text link
    Wind-blown sand, or "saltation," is an important geological process, and the primary source of atmospheric dust aerosols. Significant discrepancies exist between classical saltation theory and measurements. We show here that these discrepancies can be resolved by the inclusion of sand electrification in a physically based saltation model. Indeed, we find that electric forces enhance the concentration of saltating particles and cause them to travel closer to the surface, in agreement with measurements. Our results thus indicate that sand electrification plays an important role in saltation.Comment: 4 journal pages, 5 figures, and supplementary material. Article is in press at PR

    On the usability of augmented reality devices for interactive risk assessment

    Get PDF
    The use of Augmented Reality (AR) technologies is the new challenge of management models born under the “Industry 4.0” paradigm. The aim of the work is to evaluate the usability of two types of AR devices (tablet and see-through) employed in the training and information activities of workers according to the ISO/IEC 9126 and ISO 9241 standards. Starting from the state of the art, evaluating market and competitors and developing different concepts of interfaces, a dedicated application was programmed and, then, the usability of such devices for the professional figures involved was evaluated through experimental tests. Two reference scenarios were defined, the Department of Industrial Engineering of University of Naples Federico II and INAIL (National Institute for Insurance against Accidents at Work) laboratories, an user interface was designed and developed, as an aid in the drafting of the document for risk evaluation and subsequent training of workers. The activity is part of the IDEE Project (Interactive Design for Ergonomics), born by the collaboration between Joint Lab IDEAS and Contarp-INAIL-Regional Management for Campania. The data analysis allowed to evaluate the goodness of the devices and the degree of satisfaction in their use on the basis of the sample of users who conducted the tests. The use of AR devices produces better results than paperwork in terms of efficiency and effectiveness, but not all devices produce appreciable results in terms of user satisfaction. Although AR technologies are mature, the tasks need to be carefully defined to avoid rejection phenomena. The strong expectation, that they generate in potential users, risks to remain disappointed today for some usability limits found in currently available devices. It is necessary to start testing in pilot applications in various industrial fields in order to capture in time and adequately support this opportunity of innovation in Italy
    corecore