12,367 research outputs found

    Private Responses to Public Incentives for Invasive Species Management

    Get PDF
    In this paper the impact of public policies such as subsidies and taxation on invasive species management is explored in a Markov chain framework. Private agents react to public incentives based upon their long term expected profits and have the option of taking measures such as abatement, monitoring and reporting. Conditions for perverse incentives are derived. The impact of sequencing of taxation and subsides on spread of risks if explored. One key finding of this paper is that excessive regulation may exacerbate the invasive species problem.invasive species, Markov process, perverse incentives, taxation and subsidies, Agricultural and Food Policy, Resource /Energy Economics and Policy,

    Private Responses to Public Incentives for Invasive Species Management

    Get PDF
    In this paper the impact of public policies such as subsidies and taxation on invasive species management is explored in a Markov chain process framework. Private agents react to public incentives based upon their long term expected profits and have the option of taking measures such as abatement, monitoring and reporting. Conditions for perverse incentives are derived. The impact of sequencing of taxation and subsides on spread of risks is explored. One key finding of this paper is that excessive regulation may sometimes exacerbate the invasive species problemInvasive Species, Markov process, Perverse Incentives, Taxation and Subsidies, Agricultural and Food Policy, Agricultural Finance, Environmental Economics and Policy, Research Methods/ Statistical Methods,

    Extra-matrix Mg\u3csup\u3e2+\u3c/sup\u3e Limits Ca\u3csup\u3e2+\u3c/sup\u3e Uptake and Modulates Ca\u3csup\u3e2+\u3c/sup\u3e Uptake-independent Respiration and Redox State in Cardiac Isolated Mitochondria

    Get PDF
    Cardiac mitochondrial matrix (m) free Ca2+ ([Ca2+]m) increases primarily by Ca2+ uptake through the Ca2+ uniporter (CU). Ca2+ uptake via the CU is attenuated by extra-matrix (e) Mg2+ ([Mg2+]e). How [Ca2+]m is dynamically modulated by interacting physiological levels of [Ca2+]e and [Mg2+]e and how this interaction alters bioenergetics are not well understood. We postulated that as [Mg2+]e modulates Ca2+ uptake via the CU, it also alters bioenergetics in a matrix Ca2+–induced and matrix Ca2+–independent manner. To test this, we measured changes in [Ca2+]e, [Ca2+]m, [Mg2+]e and [Mg2+]m spectrofluorometrically in guinea pig cardiac mitochondria in response to added CaCl2 (0–0.6 mM; 1 mM EGTA buffer) with/without added MgCl2 (0–2 mM). In parallel, we assessed effects of added CaCl2 and MgCl2 on NADH, membrane potential (ΔΨm), and respiration. We found that \u3e0.125 mM MgCl2 significantly attenuated CU-mediated Ca2+ uptake and [Ca2+]m. Incremental [Mg2+]e did not reduce initial Ca2+uptake but attenuated the subsequent slower Ca2+ uptake, so that [Ca2+]m remained unaltered over time. Adding CaCl2 without MgCl2 to attain a [Ca2+]m from 46 to 221 nM enhanced state 3 NADH oxidation and increased respiration by 15 %; up to 868 nM [Ca2+]m did not additionally enhance NADH oxidation or respiration. Adding MgCl2 did not increase [Mg2+]m but it altered bioenergetics by its direct effect to decrease Ca2+ uptake. However, at a given [Ca2+]m, state 3 respiration was incrementally attenuated, and state 4 respiration enhanced, by higher [Mg2+]e. Thus, [Mg2+]e without a change in [Mg2+]m can modulate bioenergetics independently of CU-mediated Ca2+ transport

    An Imaging Polarimeter(IMPOL) for multi-wavelength observations

    Get PDF
    Taking advantage of the advances in array detector technology, an imaging polarimeter (IMPOL) has been constructed for measuring linear polarization in the wavelength band from 400-800 nm. It makes use of a Wollaston prism as the analyser to measure simultaneously the two orthogonal polarization components that define a Stoke's parameter. An achromatic half-wave plate is used to rotate the plane of polarization with respect to the axis of the analyser so that the second Stoke's parameter also can be determined. With a field of view correponding to about 30x30 sq. mm for a 1.2 m, f/13 telescope, a sensitive, liquid-nitrogen cooled CCD camera as the detector and a built-in acquisition and guidance unit, the instrument can be used for studying stellar fields or extended objects with an angular resolution close to 2 arcsec. The instrumental polarization is less than 0.05% and the accuracies of measurement are primarily limited by photon noise for typical observations.Comment: 10 pages including 5 embedded figures; submitted to Astronomy and Astrophysics Supplement Series; available on request to A. N. Ramaprakash ([email protected] or [email protected]); quote report n

    Modification to the bilge and sea water pumps fitted in 17.5 metre Jingha type trawlers

    Get PDF
    This paper brings out the difficulties encountered with the Bilge and sea water circulating pumps which are fitted and drawn in series along with a fresh water pump in the 17.5 m fishing trawlers
    • …
    corecore