14 research outputs found

    A Novel Fluorescent Imaging Agent for Diffuse Optical Tomography of the Breast: First Clinical Experience in Patients

    Get PDF
    Purpose: This is the first clinical evaluation of a novel fluorescent imaging agent (Omocianine) for breast cancer detection with diffuse optical tomography (DOT). Procedures: Eleven women suspected of breast cancer were imaged with DOT at multiple time points (up to 24 h) after receiving an intravenous injection of Omocianine (doses 0.01 to 0.1 mg/kg bodyweight). Breast MRI was obtained for comparison. Results: Histopathology showed invasive cancer in ten patients and fibroadenoma in one patient. With the lowest dose of Omocianine, two of three lesions were detected; with the second dose, three of three lesions were detected; with the two highest doses, none of five lesions were detected. Lesion location on DOT showed excellent agreement with MRI. Optimal lesion-tobackground signals were obtained after 8 h. No adverse events occurred. Conclusions: Lowest doses of Omocianine performed best in lesion detection; DOT using a lowdose fluorescent agent is feasible and safe for breast cancer visualization in patients

    Diagnosis with near infrared optical spectroscopy during minimally invasive procedures

    No full text

    Diagnosis with near infrared optical spectroscopy during minimally invasive procedures

    No full text

    Minimally Invasive Transforaminal Lumbar Interbody Fusion Using Augmented Reality Surgical Navigation for Percutaneous Pedicle Screw Placement

    No full text
    International audienceStudy Design: This was a retrospective observational study. Objective: The aim of this study was to evaluate the accuracy of percutaneous pedicle screw placement using augmented reality surgical navigation during minimally invasive transforaminal lumbar interbody fusion (TLIF). Summary of Background Data: Augmented reality-based navigation is a new type of computer-assisted navigation where video cameras are used instead of infrared cameras to track the operated patients and surgical instruments. This technology has not so far been clinically evaluated for percutaneous pedicle screw placement. Materials and Methods: The study assessed percutaneous pedicle screw placement in 20 consecutive patients who underwent single-level minimally invasive TLIF using augmented reality surgical navigation. Facet joint violation and depression by the inserted pedicle screws were evaluated. Secondary outcome such as radiation dose exposure, fluoroscopy time, and operative time were collected for 3 phases of surgery: preparation phase, pedicle screw placement, and decompression with cage placement. Results: A clinical accuracy for screw placement within the pedicle (Gertzbein 0 or 1) of 94% was achieved. One screw violated the facet joint with a transarticular pathway. The screw head did not depress the facet in 54%. The use of fluoroscopy during navigation correlated with patient body-mass index (r=0.68, P<0.0001). The pedicle screw placement time corresponded to 36±5% of the total operative time of 117±11 minutes. A statistically significant decrease of 10 minutes in operative time was observed between the first and last 10 procedures which corresponded to the pedicle screw placement time decrease (48±9 vs. 38±7 min, P=0.0142). The learning curve model suggests an ultimate operative time decrease to 97 minutes. Conclusion: Augmented reality surgical navigation can be clinically used to place percutaneous screws during minimally invasive TLIF. However, the lack of tracking of the location of the device requires intraoperative fluoroscopy to monitor screw insertion depth especially in obese patients. Level of Evidence: Level III

    Estimation of lipid and water concentrations in scattering media with diffuse optical spectroscopy from 900 to 1600 nm

    No full text
    We demonstrate a method to estimate the concentrations of water and lipid in scattering media such as biological tissues with diffuse optical spectra acquired over the range of 900 to 1600 nm. Estimations were performed by fitting the spectra to a model of light propagation in scattering media derived from diffusion theory. To validate the method, spectra were acquired from tissue phantoms consisting of lipid and water emulsions and swine tissues ex vivo with a two-fiber probe. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI:10.1117/1.3454392

    Surgical Navigation Technology Based on Augmented Reality and Integrated 3D Intraoperative Imaging: A Spine Cadaveric Feasibility and Accuracy Study.

    No full text
    Efst á síðunni er hægt að nálgast greinina í heild sinni með því að smella á hlekkinnA cadaveric laboratory study.The aim of this study was to assess the feasibility and accuracy of thoracic pedicle screw placement using augmented reality surgical navigation (ARSN).Recent advances in spinal navigation have shown improved accuracy in lumbosacral pedicle screw placement but limited benefits in the thoracic spine. 3D intraoperative imaging and instrument navigation may allow improved accuracy in pedicle screw placement, without the use of x-ray fluoroscopy, and thus opens the route to image-guided minimally invasive therapy in the thoracic spine.ARSN encompasses a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Two neurosurgeons placed 94 pedicle screws in the thoracic spine of four cadavers using ARSN on one side of the spine (47 screws) and free-hand technique on the contralateral side. X-ray fluoroscopy was not used for either technique. Four independent reviewers assessed the postoperative scans, using the Gertzbein grading. Morphometric measurements of the pedicles axial and sagittal widths and angles, as well as the vertebrae axial and sagittal rotations were performed to identify risk factors for breaches.ARSN was feasible and superior to free-hand technique with respect to overall accuracy (85% vs. 64%, P < 0.05), specifically significant increases of perfectly placed screws (51% vs. 30%, P < 0.05) and reductions in breaches beyond 4 mm (2% vs. 25%, P < 0.05). All morphometric dimensions, except for vertebral body axial rotation, were risk factors for larger breaches when performed with the free-hand method.ARSN without fluoroscopy was feasible and demonstrated higher accuracy than free-hand technique for thoracic pedicle screw placement.N/A

    Validation of Interventional Fiber Optic Spectroscopy With MR Spectroscopy, MAS-NMR Spectroscopy, High-Performance Thin-Layer Chromatography, and Histopathology for Accurate Hepatic Fat Quantification

    No full text
    Objectives: To validate near-infrared (NIR)-based optical spectroscopy measurements of hepatic fat content using a minimally invasive needle-like probe with integrated optical fibers, enabling real-time feedback during percutaneous interventions. The results were compared with magnetic resonance spectroscopy (MRS) as validation and with histopathology, being the clinical gold standard. Additionally, ex vivo magic angle spinning nuclear magnetic resonance spectroscopy and high-performance thin-layer chromatography were performed for comparison. Materials and Methods: Ten mice were used for the study, of which half received a regular chow diet and the other half received a high-fat diet to induce obesity and hepatosteatosis. The mice were imaged with a clinical 3-Tesla MR to select a region of interest within the right and left lobes of the liver, where MRS measurements were acquired in vivo. Subsequently, optical spectra were measured ex vivo at the surface of the liver at 6 different positions immediately after resection. Additionally Results: For both the mice groups, the estimated fat fractions by the various techniques were significantly similar (P = 0.072 and 0.627 for chow diet and high-fat diet group, respectively). The Pearson correlation value between NIR and the other techniques for fat determination showed the same strong linear correlation (P above 0.990; P < 0.001), whereas for histopathologic analyses, which is a rather qualitative measure, the Pearson correlation value was slightly lower (P = 0.925, P < 0.001). Conclusions: NIR spectroscopy measurements from a needle-like probe with integrated optical fibers for sensing at the tip of the needle can quickly and accurately determine hepatic fat content during an interventional procedure and might therefore be a promising novel diagnosing tool in the clinic
    corecore