228 research outputs found

    Persistent circulating platelet and endothelial derived microparticle signature may explain on-going pro-thrombogenicity after acute coronary syndrome

    Get PDF
    Aims: Microparticles (MPs) are submicron vesicles, released from activated, and apoptotic cells. MPs are elevated in the circulation of patients with coronary artery disease (CAD) and have pro-thrombotic potential. However, limited data exists on MP signature over time following an acute coronary event. / Methods & results: Circulating total annexin v + (Anv+) MPs of endothelial (EMP), platelet (PMP), monocyte (MMP), neutrophil (NMP) and smooth muscle cell (SMMP) origin were quantified by flow cytometry. 13 patients with acute coronary syndrome (ACS) were prospectively enrolled and 12 patients with stable angina (SA) were included as a comparator group. A panel of MP was measured at baseline, after percutaneous coronary intervention (PCI) and at days 1, 7, 30 and 6 months. Intra & inter group comparison was made between various time points. MP mediated thrombin generation was measured by recording lag phase, velocity index, peak thrombin and endogenous thrombin potential at these time points and compared with healthy controls. The total AnV+ MP levels were similar in ACS and SA groups at baseline, peaked immediately after PCI and were at their lowest on day 1. PMP & EMP levels remained significantly elevated in ACS patients at 6 months when compared to SA. No such difference was noted with NMP, MMP and SMMP. Patients with coronary artery disease showed abnormal thrombograms when compared to controls. Peak thrombin (nano moles) was significantly higher in CAD when compared to controls (254 IQR [226, 239] in ACS, 255 IQR [219, 328] in SA and 132 IQR [57, 252] in controls; p = 0.006). Differences in thrombin generation between ACS and SA were not significant (p = 1). Furthermore, thrombin parameters remained abnormal in ACS & SA patients at 6 months. / Conclusions: Total MP and individual MP phenotypes were significantly elevated after PCI reflecting endothelial injury. Elevated PMP and EMP levels at 6 months in ACS patients is suggestive of on-going inflammation, endothelial injury and may explain on-going pro-thrombogenicity seen up to 6 months after ACS despite dual antiplatelet therapy

    Agreement of wall shear stress distribution between two core laboratories using three-dimensional quantitative coronary angiography

    Get PDF
    Wall shear stress (WSS) estimated in models reconstructed from intravascular imaging and 3-dimensional-quantitative coronary angiography (3D-QCA) data provides important prognostic information and enables identification of high-risk lesions. However, these analyses are time-consuming and require expertise, limiting WSS adoption in clinical practice. Recently, a novel software has been developed for real-time computation of time-averaged WSS (TAWSS) and multidirectional WSS distribution. This study aims to examine its inter-corelab reproducibility. Sixty lesions (20 coronary bifurcations) with a borderline negative fractional flow reserve were processed using the CAAS Workstation WSS prototype to estimate WSS and multi-directional WSS values. Analysis was performed by two corelabs and their estimations for the WSS in 3 mm segments across each reconstructed vessel was extracted and compared. In total 700 segments (256 located in bifurcated vessels) were included in the analysis. A high intra-class correlation was noted for all the 3D-QCA and TAWSS metrics between the estimations of the two corelabs irrespective of the presence (range: 0.90–0.92) or absence (range: 0.89–0.90) of a coronary bifurcation, while the ICC was good-moderate for the multidirectional WSS (range: 0.72–0.86). Lesion level analysis demonstrated a high agreement of the two corelabls for detecting lesions exposed to an unfavourable haemodynamic environment (WSS > 8.24 Pa, κ = 0.77) that had a high-risk morphology (area stenosis > 61.3%, κ = 0.71) and were prone to progress and cause events. The CAAS Workstation WSS enables reproducible 3D-QCA reconstruction and computation of WSS metrics. Further research is needed to explore its value in detecting high-risk lesions

    Association of systemic inflammatory biomarkers with morphological characteristics of coronary atherosclerotic plaque by intravascular optical coherence tomography

    Get PDF
    Despite significant advances in preventive, medical, and interventional management, coronary artery disease remains the leading cause of death worldwide. We now know that in the majority of acute coronary syndromes, a thrombotic event is triggered either by the rupture or erosion of the so-called high-risk or ‘vulnerable’ plaque. However, accurately identifying the individual who is at significant risk of acute event remains the holy grail of preventive cardiology. To better stratify an individual's risk of developing and suffering a cardiovascular event, biomarkers are needed that can accurately predict coronary events and, if possible, monitor disease activity in response to medical or interventional therapies. In order to be able to understand the association of these biomarkers with the morphological substrate of high-risk plaques, intravascular imaging modalities can provide invaluable assistance. Novel imaging tools such as optical coherence tomography (OCT) have not only helped in identifying atherosclerotic plaque characteristics that are unstable but also in estimating global plaque burden. In this study, we provide an overview of our current knowledge of association of various inflammatory markers with atherosclerotic plaque characteristics seen on OCT

    Prospective comparison of novel dark blood late gadolinium enhancement with conventional bright blood imaging for the detection of scar

    Get PDF
    BACKGROUND: Conventional bright blood late gadolinium enhancement (bright blood LGE) imaging is a routine cardiovascular magnetic resonance (CMR) technique offering excellent contrast between areas of LGE and normal myocardium. However, contrast between LGE and blood is frequently poor. Dark blood LGE (DB LGE) employs an inversion recovery T2 preparation to suppress the blood pool, thereby increasing the contrast between the endocardium and blood. The objective of this study is to compare the diagnostic utility of a novel DB phase sensitive inversion recovery (PSIR) LGE CMR sequence to standard bright blood PSIR LGE. METHODS: One hundred seventy-two patients referred for clinical CMR were scanned. A full left ventricle short axis stack was performed using both techniques, varying which was performed first in a 1:1 ratio. Two experienced observers analyzed all bright blood LGE and DB LGE stacks, which were randomized and anonymized. A scoring system was devised to quantify the presence and extent of gadolinium enhancement and the confidence with which the diagnosis could be made. RESULTS: A total of 2752 LV segments were analyzed. There was very good inter-observer correlation for quantifying LGE. DB LGE analysis found 41.5% more segments that exhibited hyperenhancement in comparison to bright blood LGE (248/2752 segments (9.0%) positive for LGE with bright blood; 351/2752 segments (12.8%) positive for LGE with DB; p < 0.05). DB LGE also allowed observers to be more confident when diagnosing LGE (bright blood LGE high confidence in 154/248 regions (62.1%); DB LGE in 275/324 (84.9%) regions (p < 0.05)). Eighteen patients with no bright blood LGE were found to have had DB LGE, 15 of whom had no known history of myocardial infarction. CONCLUSIONS: DB LGE significantly increases LGE detection compared to standard bright blood LGE. It also increases observer confidence, particularly for subendocardial LGE, which may have important clinical implications

    Quantitative cardiovascular magnetic resonance myocardial perfusion mapping to assess hyperaemic response to adenosine stress

    Get PDF
    AIMS: Assessment of hyperaemia during adenosine stress cardiovascular magnetic resonance (CMR) remains a clinical challenge with lack of a gold-standard non-invasive clinical marker to confirm hyperaemic response. This study aimed to validate maximum stress myocardial blood flow (SMBF) measured using quantitative perfusion mapping for assessment of hyperaemic response and compare this to current clinical markers of adenosine stress. METHODS AND RESULTS: Two hundred and eighteen subjects underwent adenosine stress CMR. A derivation cohort (22 volunteers) was used to identify a SMBF threshold value for hyperaemia. This was tested in a validation cohort (37 patients with suspected coronary artery disease) who underwent invasive coronary physiology assessment on the same day as CMR. A clinical cohort (159 patients) was used to compare SMBF to other physiological markers of hyperaemia [splenic switch-off (SSO), heart rate response (HRR), and blood pressure (BP) fall]. A minimum SMBF threshold of 1.43 mL/g/min was derived from volunteer scans. All patients in the coronary physiology cohort demonstrated regional maximum SMBF (SMBFmax) >1.43 mL/g/min and invasive evidence of hyperaemia. Of the clinical cohort, 93% had hyperaemia defined by perfusion mapping compared to 71% using SSO and 81% using HRR. There was no difference in SMBFmax in those with or without SSO (2.58 ± 0.89 vs. 2.54 ± 1.04 mL/g/min, P = 0.84) but those with HRR had significantly higher SMBFmax (2.66 1.86 mL/g/min, P 15 bpm was superior to SSO in predicting adequate increase in SMBF (AUC 0.87 vs. 0.62, P < 0.001). CONCLUSION: Adenosine-induced increase in myocardial blood flow is accurate for confirmation of hyperaemia during stress CMR studies and is superior to traditional, clinically used markers of adequate stress such as SSO and BP response

    A randomized double-blind control study of early intra-coronary autologous bone marrow cell infusion in acute myocardial infarction: the REGENERATE-AMI clinical trial

    Get PDF
    Clinical trials suggest that intracoronary delivery of autologous bone marrow-derived cells (BMCs) 1–7 days post-acute myocardial infarction (AMI) may improve left ventricular (LV) function. Earlier time points have not been evaluated. We sought to determine the effect of intracoronary autologous BMC on LV function when delivered within 24 h of successful reperfusion therapy. Methods and results A multi-centre phase II randomized, double-blind, and placebo-controlled trial. One hundred patients with anterior AMI and significant regional wall motion abnormality were randomized to receive either intracoronary infusion of BMC or placebo (1:1) within 24 h of successful primary percutaneous intervention (PPCI). The primary endpoint was the change in left ventricular ejection fraction (LVEF) between baseline and 1 year as determined by advanced cardiac imaging. At 1 year, although LVEF increased compared with baseline in both groups, the between-group difference favouring BMC was small (2.2%; 95% confidence interval, CI: −0.5 to 5.0; P = 0.10). However, there was a significantly greater myocardial salvage index in the BMC-treated group compared with placebo (0.1%; 95% CI: 0.0–0.20; P = 0.048). Major adverse events were rare in both treatment groups. Conclusion The early infusion of intracoronary BMC following PPCI for patients with AMI and regional wall motion abnormality leads to a small non-significant improvement in LVEF when compared with placebo; however, it may play an important role in infarct remodelling and myocardial salvage.UK Stem Cells Foundation, the Heart Cells Foundation, and Barts and the London Charity. Funding to pay the Open Access publication charges for this article was provided by the Barts Cardiovascular Biomedical Research Unit (CVBRU)

    Adherent Monomer-Misfolded SOD1

    Get PDF
    Background: Multiple cellular functions are compromised in amyotrophic lateral sclerosis (ALS). In familial ALS (FALS) with Cu/Zn superoxide dismutase (SOD1) mutations, the mechanisms by which the mutation in SOD1 leads to such a wide range of abnormalities remains elusive. Methodology/Principal Findings: To investigate underlying cellular conditions caused by the SOD1 mutation, we explored mutant SOD1-interacting proteins in the spinal cord of symptomatic transgenic mice expressing a mutant SOD1, SOD1 Leu126delTT with a FLAG sequence (DF mice). This gene product is structurally unable to form a functional homodimer. Tissues were obtained from both DF mice and disease-free mice expressing wild-type with FLAG SOD1 (WF mice). Both FLAG-tagged SOD1 and cross-linking proteins were enriched and subjected to a shotgun proteomic analysis. We identified 34 proteins (or protein subunits) in DF preparations, while in WF preparations, interactions were detected with only 4 proteins. Conclusions/Significance: These results indicate that disease-causing mutant SOD1 likely leads to inadequate proteinprotein interactions. This could be an early and crucial process in the pathogenesis of FALS

    Assessment of Multivessel Coronary Artery Disease Using Cardiovascular Magnetic Resonance Pixelwise Quantitative Perfusion Mapping

    Get PDF
    OBJECTIVES: The authors sought to compare the diagnostic accuracy of quantitative perfusion maps to visual assessment (VA) of first-pass perfusion images for the detection of multivessel coronary artery disease (MVCAD). BACKGROUND: VA of first-pass stress perfusion cardiac magnetic resonance (CMR) may underestimate ischemia in MVCAD. Pixelwise perfusion mapping allows quantitative measurement of regional myocardial blood flow, which may improve ischemia detection in MVCAD. METHODS: One hundred fifty-one subjects recruited at 2 centers underwent stress perfusion CMR with myocardial perfusion mapping, and invasive coronary angiography with coronary physiology assessment. Ischemic burden was assessed by VA of first-pass images and by quantitative measurement of stress myocardial blood flow using perfusion maps. RESULTS: In patients with MVCAD (2-vessel [2VD] or 3-vessel disease [3VD]; n = 95), perfusion mapping identified significantly more segments with perfusion defects (median segments per patient 12 [interquartile range (IQR): 9 to 16] by mapping vs. 8 [IQR: 5 to 9.5] by VA; p < 0.001). Ischemic burden (IB) measured using mapping was higher in MVCAD compared with IB measured using VA (3VD mapping 100 % (75% to 100%) vs. first-pass 56% (38% to 81%) ; 2VD mapping 63% (50% to 75%) vs. first-pass 41% (31% to 50%); both p < 0.001), but there was no difference in single-vessel disease (mapping 25% (13% to 44%) vs. 25% (13% to 31%). Perfusion mapping was superior to VA for the correct identification of extent of coronary disease (78% vs. 58%; p < 0.001) due to better identification of 3VD (87% vs. 40%) and 2VD (71% vs. 48%). CONCLUSIONS: VA of first-pass stress perfusion underestimates ischemic burden in MVCAD. Pixelwise quantitative perfusion mapping increases the accuracy of CMR in correctly identifying extent of coronary disease. This has important implications for assessment of ischemia and therapeutic decision-making

    Micron resolution, high-fidelity three-dimensional vascular optical imaging phantoms

    Get PDF
    Microscopic and mesoscale optical imaging techniques allow for three-dimensional (3-D) imaging of biological tissue across millimeter-scale regions, and imaging phantom models are invaluable for system characterization and clinical training. Phantom models that replicate complex 3-D geometries with both structural and molecular contrast, with resolution and lateral dimensions equivalent to those of imaging techniques (<20  μm), have proven elusive. We present a method for fabricating phantom models using a combination of two-photon polymerization (2PP) to print scaffolds, and microinjection of tailored tissue-mimicking materials to simulate healthy and diseased tissue. We provide a first demonstration of the capabilities of this method with intravascular optical coherence tomography, an imaging technique widely used in clinical practice. We describe the design, fabrication, and validation of three types of phantom models: a first with subresolution wires (5- to 34-μm diameter) arranged circumferentially, a second with a vessel side-branch, and a third containing a lipid inclusion within a vessel. Silicone hybrid materials and lipids, microinjected within a resin framework created with 2PP, served as tissue-mimicking materials that provided realistic optical scattering and absorption. We demonstrate that optical phantom models made with 2PP and microinjected tissue-mimicking materials can simulate complex anatomy and pathology with exquisite detail
    corecore