7 research outputs found

    Iatrogenic femoral nerve palsy after a routine knee ligament surgery

    Get PDF
    Peripheral nerve injuries following surgery can have a significant impact on the rehabilitation process. We report a case of a 25-year-old male who was unable to actively raise his leg and extend his knee following knee surgery (Arthroscopic Posterior cruciate ligament reconstruction and Posterolateral corner reconstruction). Following the surgery, it was noticed that the patient's knee range of movements and power was 0/5 as per the Medical Research Council (MRC) scale. On subsequent evaluation, it was found to be due to femoral nerve axonal neuropathy. We report such a case of femoral nerve axonal neuropathy following arthroscopic posterior cruciate ligament (PCL) reconstruction and posterolateral corner (PLC) reconstruction

    Trans-osseous intraoperative limb length measurement in hip replacement surgery

    Get PDF
    Background: Discrepancy of the limb length following total hip replacement is one of common complication. To reduce the occurrence, various modalities are used like pre-operative templating, navigation assisted measurements and intraoperative methods. This study was done using trans-osseous method of measurement using hip gauge which provides a faster, simpler assessment of limb length.Methods: A prospective study of 25 patients who underwent uncemented hip arthroplasty was taken in the study and the LLD was measured before and after the surgical procedure. Patient were re-assessed for limb length discrepancy after 6 months with functional Harris hip score and radiological analysis on weight bearing standard X-ray antero-posterior view of the pelvis with bilateral hip joint.Results: The results showed significant improvement in limb length discrepancy, and analysis of postoperative radiographs found the mean length difference of 2.44 mm and average Harris hip score was 95.5. No device related complications were reported, and none of them complained of the discomfort related to limb-length discrepancy after surgery. Conclusions: Trans-osseous fixed method using hip gauge provides a faster, reproducible and simpler method for the assessment of Limb length and aids with offset placement, acetabular anteversion for precise cup placement. This is a reliable method as it can be used both in the primary and revision hip surgery and most importantly doesn’t require any additional intraoperative imaging

    Arthroscopic management of neglected complex knee injury

    Get PDF
    Meyers and mckeevers type IV comminuted pattern of avulsion fracture of the anterior tibial eminence is not an uncommon injury, however its association with root avulsions of lateral and medial meniscus is very rare combination of injury and the management of the neglected case of this complex knee injury is challenging. A 43-year-old gentleman who came with a history of pain, recurrent instability, locking of his right knee for 2 weeks with restricted activity of daily living. He also had a road traffic accident 5 years ago. He was evaluated clinically, radiologically by X Rays and MRI Scan which revealed complete tear of anterior cruciate ligament (ACL) with loose fragments, root tear anterior horn lateral meniscus and posterior horn tear with posterior root avulsion of the medial meniscus. He was managed with arthroscopic removal of large loose body with other loose bony fragments, ACL Reconstruction with hamstring autograft, anterior root repair of lateral meniscus with pull out sutures, with all inside repair of posterior horn tear of medial meniscus using fast-fix 360 device (Smith and Nephew, Andover, MA). At 4 years follow-up the patient was analysed clinically, and the functional outcome was measured with international knee documentation committee (IKDC) and knee injury and osteoarthritis outcome score (KOOS) Scoring system which showed good outcome. Patient has returned to his pre-injury activity level with no limitation of his activity of daily living. There is no set protocol of managing these kinds of neglected complex knee injury. Sometimes you need to think out of the box. A thorough knowledge of anatomy and pathomechanics of knee combined with appropriate technique of repair to save the meniscus and reconstruction of ACL and rehabilitation can yield good result

    A subscapularis-preserving arthroscopic release of capsule in the treatment of internal rotation contracture of shoulder in Erb's palsy (SPARC procedure)

    Get PDF
    The purpose of this study was to evaluate a minimally invasive subscapularis-preserving arthroscopic release of capsule in the treatment of internal rotation contracture of the shoulder due to Erb's palsy. We performed our procedure (subscapularis-preserving arthroscopic release of capsule) in 10 paediatric shoulders with an average age of 20.2 months and followed them for an average period of 41.5 months. All the patients were assessed clinically and radiologically preoperatively and postoperatively at regular intervals. The Mallet scoring system was used for analysing the results. The average gain in passive external rotation was 508. The active internal rotation was preserved in all the cases. With the mid-term follow-up, there was no loss of the gained external rotation or the recurrence of internal rotation contracture of the shoulder. Our hypothesis has achieved its goal in preserving subscapularis, active internal rotation and treatment of internal rotation contracture of the shoulder. The success of this procedure lies in the early identification of starting of internal rotation contracture and early surgical intervention to prevent progressive permanent glenohumeral osseocartilaginous deformity

    Effects of irrigation fluid in shoulder arthroscopy

    No full text
    Background and Aims: Extravasation of irrigation fluid used in shoulder arthroscopy can lead to life-threatening airway and systemic complications. This study was conducted to assess the effect of irrigation fluid absorption on measurable anthropometric parameters and to identify whether these parameters predict airway/respiratory compromise. Methods: Thirty six American Society of Anaesthesiologists physical status one or two patients aged 15–60 years undergoing shoulder arthroscopy under general anaesthesia were recruited. Measured variables preoperatively (baseline) and at the end of surgery were neck, chest, midarm and midthigh circumferences, weight, haemoglobin and serum sodium. Temperature, endotracheal tube cuff pressure, airway pressure, duration of surgery, amount of irrigation fluid and intravenous fluid used were also noted. Measured parameters were correlated with the duration of surgery and the amount of irrigation fluid used. Results: Postoperatively, the changes in variables showed a significant increase in the mean values (cm) for neck, chest, midarm and midthigh circumference (mean ± standard deviation: 2.35 ± 1.9, P < 0.001; 2.9 ± 3.88 cm, P < 0.001; 3.28 ± 2.44, P < 0.001 and 0.39 ± 0.71, P = 0.002, respectively) and weight (kg) (1.17 ± 1.24, P < 0.001). The post-operative haemoglobin (g/dL) levels decreased significantly (0.89 ± 1.23, P < 0.001) as compared to the baseline. No significant change was found in the serum sodium levels (P = 0.92). No patient experienced airway/respiratory compromise. Conclusion: Regional and systemic absorption of irrigation fluid in arthroscopic shoulder surgery is reflected in the degree of change in the measured anthropometric variables. However, this change was not significant enough to cause airway/respiratory compromise

    Periosteum-Augmented Soft-Tissue Graft for Anterior Cruciate Ligament Reconstruction

    No full text
    Soft-tissue grafts are an option for anterior cruciate ligament reconstruction. One of the major drawbacks of soft-tissue grafts is the delay in the osteointegration and ligamentization of the implanted graft. Enveloping the ends of the graft with periosteum sleeves can hasten the osteointegration process and help in quicker rehabilitation of the patient. This article describes a simple and unique way to augment the soft-tissue graft with periosteum for anterior cruciate ligament reconstruction
    corecore