733 research outputs found

    The Transition from Heavy Fermion to Mixed Valence in Ce1-xYxAl3: A Quantitative Comparison with the Anderson Impurity Model

    Full text link
    We present a neutron scattering investigation of Ce1-xYxAl3 as a function of chemical pressure, which induces a transition from heavy-fermion behavior in CeAl3 (TK=5 K) to a mixed-valence state at x=0.5 (TK=150 K). The crossover can be modeled accurately on an absolute intensity scale by an increase in the k-f hybridization, Vkf, within the Anderson impurity model. Surprisingly, the principal effect of the increasing Vkf is not to broaden the low-energy components of the dynamic magnetic susceptibility but to transfer spectral weight to high energy.Comment: 4 pages, 5 figure

    A questionnaire survey reviewing radiologists’ and clinical specialist radiographers’ knowledge of CT exposure parameters

    Get PDF
    OBJECTIVE: To review knowledge of computed tomography (CT) parameters and their influence on patient dose and image quality amongst a cohort of clinical specialist radiographers (CSRs) and examining radiologists. METHODS: A questionnaire survey was devised and distributed to a cohort of 65 examining radiologists attending the American Board of Radiology exam in Kentucky in November 2011. The questionnaire was later distributed by post to a matching cohort of Irish CT CSRs. Each questionnaire contained 40 questions concerning CT parameters and their influence on both patient dose and image quality. RESULTS: A response rate of 22 % (radiologists) and 32 % (CSRs) was achieved. No difference in mean scores was detected between either group (27.8 ± 4 vs 28.1 ± 4, P = 0.87) although large ranges were noted (18–36). Considerable variations in understanding of CT parameters was identified, especially regarding operation of automatic exposure control and the influence of kilovoltage and tube current on patient dose and image quality. Radiologists were unaware of recommended diagnostic reference levels. Both cohorts were concerned regarding CT doses in their departments. CONCLUSIONS: CT parameters were well understood by both groups. However, a number of deficiencies were noted which may have a considerable impact on patient doses and limit the potential for optimisation in clinical practice. KEY POINTS: • CT users must adapt parameters to optimise patient dose and image quality. • The influence of some parameters is not well understood. • A need for ongoing education in dose optimisation is identified

    Electronic structure of the muonium center as a shallow donor in ZnO

    Full text link
    The electronic structure and the location of muonium centers (Mu) in single-crystalline ZnO were determined for the first time. Two species of Mu centers with extremely small hyperfine parameters have been observed below 40 K. Both Mu centers have an axial-symmetric hyperfine structure along with a [0001] axis, indicating that they are located at the AB_{O,//} and BC_{//} sites. It is inferred from their small ionization energy (~6 meV and 50 meV) and hyperfine parameters (~10^{-4} times the vacuum value) that these centers behave as shallow donors, strongly suggesting that hydrogen is one of the primary origins of n type conductivity in as-grown ZnO.Comment: 4 pages, 4 figures, submitted to PR

    Clinical radiography education across Europe

    Get PDF
    Purpose: To establish a picture of clinical education models within radiography programmes across Europe by surveying higher education institutions registered as affiliate members of the European Federation of Radiography Societies (EFRS). Method: An online survey was developed to ascertain data on: practical training, supervisory arrangements, placement logistics, quality assurance processes, and the assessment of clinical competencies. Responses were identifiable in terms of educational institution and country. All educational institutions who were affiliate members at the time of the study were invited to participate (n=46). Descriptive and thematic analyses are reported. Results: A response rate of 82.6% (n=38) was achieved from educational institutions representing 21 countries. Over half of responding institutions (n=21) allocated in excess of 60 European Credit Transfer and Accumulation System (ECTS) credits to practical training. In nearly three-quarters of clinical placements there was a dedicated clinical practice supervisor in place; two-thirds of these were employed directly by the hospital. Clinical practice supervisors were typically state registered radiographers, who had a number of years of clinical experience and had received specific training for the role. Typical responsibilities included monitoring student progress, providing feedback and completing paperwork, this did however vary between respondents. In almost all institutions there were support systems in place for clinical placement supervisors within their roles. Conclusions: Similarities exist in the provision of clinical radiography education across Europe. Clinical placements are a core component of radiography education and are supported by experienced clinical practice supervisors. Mechanisms are in place for the selection, training and support of clinical practice supervisors. Professional societies should work collaboratively to establish guidelines for effective clinical placements

    Development of a framework for radiographer online clinical education (FORCE): the specifc strand of nuclear medicine within this european project

    Get PDF
    The overall aim of the FORCE project is to develop virtual web-based learning resources where Radiography undergraduates can engage in interactive, problem-based development of radiographic knowledge, ability and professional awareness. This European-funded project is internally divided in three diferent strands (Radiology Diagnostic Imaging, Radiotherapy and Nuclear Medicine). The aim of this presentation is to present the global project, mainly focusing developments, achievements and challenges within the Nuclear Medicine specifc strand.info:eu-repo/semantics/publishedVersio
    • …
    corecore