Study of heating performance of radiant ceiling heating system and its impact on workers thermal comfort level of workers in typical industrial work shops
Introduction: Introduction: Thermal comforts are one of the most human concerns in working as was as living environments in the past half century. Thermal comfort is the condition in which people are satisfied with the thermal environment, mentally. One of the new heating system employed in individual units is radiant heating system .The purpose of this study was to investigate the performance of radiant ceiling heating system and its impact on thermal comfort of workers..
Material and Method: In the present analytical-descriptive study, the designed radiant heating systems were investigated in two repair and maintenance units, in Hamadan gas pipeline operation center. Firstly, the environment parameters, witch impact thermal comfort, were measured before and after using radiant heating system, in both understudy units. Then, wind chill index, thermal comfort indices, PMV and PPD were calculated. In addition, PPD and PMV were determined, based on workers subjective feeling by a questionnaire distributed among 22 workers.
.Results: According to the results, the radiant heating system in unit 1, has reduced the wind chill index by 42.3 Kcal/ m2.h, witch is not considered to be significant. In unit 2, wind chill index has been decreased by 109.3 Kcal/ m2.h, witch mean that thermal comfort has been changed from cold to an optimum environment. PMV n unit 1 went up by 37% after turning the system on, witch is equal to 17.24% increase in workers satisfaction. However, in unit 2, the workers satisfaction was 14.3% higher in comparison with unit 1.
.Conclusion: Due to large space of these industrial units, producing appropriate heating by convection mechanism is too difficult and expensive. The results confirmed that if radiant heating system applied based on scientific design principles they could be effective in promotion of thermal comfort due to heating surrounding surface by radiant and also reducing fuel consumption
The effect of side quantum dots on conductance through four-quantum-dot combinations: study by non-equilibrium Greens function method
Electronic transport has been investigated in four-quantum-dot combination coupled to metal electrodes using the non-equilibrium Green’s function method, and curves I-V and conductance (dI/dV) were analyzed for special combination. We have showed that the emergence of negative differential conductivity is due to asymmetric distribution of quantum dots in the central region, existence of non-coupled dots (side quantum dots), and the interference effect. We found that more side quantum dots lead to more negative differential conductance
A New Weighting Approach to Non-Parametric Composite Indices Compared with Principal Components Analysis
Introduction of Human Development Index (HDI) by UNDP in early 1990 followed a surge in use of non-parametric and parametric indices for measurement and comparison of countries performance in development, globalization, competition, well-being and etc. The HDI is a composite index of three indicators. Its components are to reflect three major dimensions of human development: longevity, knowledge and access to resources represented by GDP per capita, educational attainment and life expectancy. In recent years additional gender and poverty aspects are included. A known example of the non-parametric index is the HDI, while Principal Components Analysis (PCA) and Factor Analysis (FA) are among the parametric counterparts. The indices differ mainly in respect to weighting the indicators in their aggregation. The non-parametric index assumes the weights, while the parametric approach estimates them. In this research, it is aimed to purpose a new weighting approach to non-parametric indices when they are used simultaneous with principal components analysis