110 research outputs found
Monitoring vegetation dynamics using multi-temporal Normalized Difference Vegetation Index (NDVI) and Enhanced Vegetation Index (EVI) images of Tamil Nadu
Vegetation indices serve as an essential tool in monitoring variations in vegetation. The vegetation indices used often, viz., normalized difference vegetation index (NDVI) and enhanced vegetation index (EVI) were computed from MODIS vegetation index products. The present study aimed to monitor vegetation's seasonal dynamics by using time series NDVI and EVI indices in Tamil Nadu from 2011 to 2021. Two products characterize the global range of vegetation states and processes more effectively. The data sources were processed and the values of NDVI and EVI were extracted using ArcGIS software. There was a significant difference in vegetation intensity and status of vegetation over time, with NDVI having a larger value than EVI, indicating that biomass intensity varies over time in Tamil Nadu. Among the land cover classes, the deciduous forest showed the highest mean values for NDVI (0.83) and EVI (0.38), followed by cropland mean values of NDVI (0.71) and EVI (0.31) and the lowest NDVI (0.68) and EVI (0.29) was recorded in the scrubland. The study demonstrated that vegetation indices extracted from MODIS offered valuable information on vegetation status and condition at a short temporal time period
An interactive web-based educational tool improves detection and delineation of Barrett’s esophagus related neoplasia
Background & Aims: Endoscopic detection of early Barrett’s esophagus-related neoplasia (BORN) is a challenge. We aimed to develop a web-based teaching tool for improving detection and delineation of BORN. Methods: We made high-definition digital videos during endoscopies of patients with BORN and non-dysplastic Barrett’s esophagus (NDBE). Three experts superimposed their delineations of BORN lesions on the videos using special tools. In phase 1, 68 general endoscopists from 4 countries assessed 4 batches of 20 videos. After each batch, mandatory feedback compared assessors interpretations with those from experts . These data informed selection of 25 videos for the phase 2 module, which was completed by 121 new assessors from 5 countries. A 5-video test batch was completed before and after scoring of the four 5-video training batches. Mandatory feedback was as in phase 1. Outcome measures were scores for detection, delineation, agreement delineation, and relative delineation of BORN. Results: A linear mixed-effect model showed significant sequential improvement for all 4 outcomes over successive training batches in both phases. In phase 2, median detection rates of BORN in the test batch increased by 30% (P [less than].001) after training. From baseline to the end of the study, there were relative increases in scores of 46% for detection, 129% for delineation, 105% for agreement delineation, and 106% for relative delineation (all P [less than].001). Scores improved independent of assessors’ country of origin or level of endoscopic experience
Utility and Cost-Effectiveness of a Nonendoscopic Approach to Barrett's Esophagus Surveillance After Endoscopic Therapy
BACKGROUND & AIMS: A non-endoscopic approach to Barrett's esophagus (BE) surveillance after radiofrequency ablation (RFA) would offer a less invasive method for monitoring. We assessed the test characteristics and cost-effectiveness of the Cytosponge® in post-RFA patients. METHODS: We performed a multicenter study of dysplastic BE patients after at least one round of RFA. A positive Cytosponge® before endoscopy was defined as intestinal metaplasia (IM) on cytological assessment and/or TFF3 immunohistochemistry. Sensitivity, specificity, and receiver operator characteristic (ROC) curves were calculated. Multivariable regression was used to estimate the odds of a positive Cytosponge® in BE. A microsimulation cost-effectiveness model was performed to assess outcomes of various surveillance strategies: endoscopy-only, Cytosponge®-only, and alternating endoscopy/Cytosponge®. RESULTS: Of 234 patients, Cytosponge® adequately sampled the distal esophagus in 175 (75%). Of the 142 with both endoscopic and histologic data, 19 (13%) had residual/recurrent BE. For detecting any residual Barrett's, Cytosponge® had a sensitivity of 74%, specificity of 85%, accuracy of 84%, and ROC curve showed an area under the curve of 0.74. The adjusted odds of a positive Cytosponge® in BE were 17.1 (95% CI: 5.2-55.9). Cytosponge®-only surveillance dominated all the surveillance strategies, being both less costly and more effective. Cytosponge®-only surveillance required <1/4th the endoscopies, resulting in only 0.69 additional EAC cases/1,000 patients, and no increase in EAC deaths when compared to currently-practiced endoscopy-only surveillance. CONCLUSIONS: A positive Cytosponge® test was strongly associated with residual BE after ablation. While the assay needs further refinement in this context, it could serve as a cost-effective surveillance examination
Radiofrequency ablation for Barrett's oesophagus related neoplasia with the 360 Express catheter: initial experience from the United Kingdom and Ireland—preliminary results
BACKGROUND: Radio-frequency ablation (RFA) for Barrett's oesophagus (BE)-related neoplasia is currently used after endoscopic resection of visible neoplasia. The HALO 360 balloon has been used to ablate long segment BE. The Barrx™ 360 Express RFA self-sizing catheter ('RFA Express') may potentially allow quicker ablation times and improved treatment outcomes. The aim of this paper is to present real world data on the use of the 360 Express Device. METHODS: Centres in the UK and Ireland submitted cases where the RFA Express was used. The primary outcome was regression of BE at 3 months. Secondary outcomes were the rate of symptomatic stricture formation and resolution of intestinal metaplasia (CR-IM) and dysplasia (CR-D) at End of Treatment (EoT). RESULTS: 11 centres submitted 123 consecutive patients. 112 had a follow up endoscopy. The median age was 67 years (IQR 62-75). 3 dosimetries were used. The mean reduction in Circumferential (C) length was 78% ± 36 and mean reduction in Maximal length (M) was 55% ± 36. 17 patients (15%) developed strictures requiring dilation. There was a higher rate of stricture formation when the 12 J energy was used (p < 0.05). 47 patients had EoT biopsies, 40 (85%) had CR-D and 34(76%) had CR-IM. CONCLUSIONS: The RFA 360 Express catheter shows reduction in length of baseline BE at 3 months after index treatment, and eradication of intestinal metaplasia and dysplasia at 12 months similar to other studies with earlier devices. It appears that the symptomatic stricture rate is slightly higher than previous series with the HALO 360 catheter. This study was performed as part of the HALO registry and has been approved by the Research Ethics Committee - MREC Number 08/H0714/27 Local project reference 08/0104 Project ID 15,033 IRAS Number 54678 EudraCT 2009-015980-1. Registered on ISRCTN as below: ISRCTN93069556. https://doi.org/10.1186/ISRCTN93069556
UK guidelines on oesophageal dilatation in clinical practice
These are updated guidelines which supersede the original version published in 2004. This work has been endorsed by the Clinical Services and Standards Committee of the British Society of Gastroenterology (BSG) under the auspices of the oesophageal section of the BSG. The original guidelines have undergone extensive revision by the 16 members of the Guideline Development Group with representation from individuals across all relevant disciplines, including the Heartburn Cancer UK charity, a nursing representative and a patient representative. The methodological rigour and transparency of the guideline development processes were appraised using the revised Appraisal of Guidelines for Research and Evaluation (AGREE II) tool.
Dilatation of the oesophagus is a relatively high-risk intervention, and is required by an increasing range of disease states. Moreover, there is scarcity of evidence in the literature to guide clinicians on how to safely perform this procedure. These guidelines deal specifically with the dilatation procedure using balloon or bougie devices as a primary treatment strategy for non-malignant narrowing of the oesophagus. The use of stents is outside the remit of this paper; however, for cases of dilatation failure, alternative techniques—including stents—will be listed. The guideline is divided into the following subheadings: (1) patient preparation; (2) the dilatation procedure; (3) aftercare and (4) disease-specific considerations. A systematic literature search was performed. The Grading of Recommendations Assessment, DevelopÂment and Evaluation (GRADE) tool was used to evaluate the quality of evidence and decide on the strength of recommendations made
Acceptability, Accuracy and Safety of Disposable Transnasal Capsule Endoscopy for Barrett’s Esophagus Screening
BACKGROUND & AIMS: Screening for Barrett's esophagus (BE) with conventional esophagogastroduodenoscopy (C-EGD) is expensive. We assessed the performance of a clinic-based, single use transnasal capsule endoscope (EG Scan II) for the detection of BE, compared to C-EGD as the reference standard. METHODS: We performed a prospective multicenter cohort study of patients with and without BE recruited from 3 referral centers (1 in the United States and 2 in the United Kingdom). Of 200 consenting participants, 178 (89%) completed both procedures (11% failed EG Scan due to the inability to intubate the nasopharynx). The mean age of participants was 57.9 years and 67% were male. The prevalence of BE was 53%. All subjects underwent the 2 procedures on the same day, performed by blinded endoscopists. Patients completed preference and validated tolerability (10-point visual analogue scale [VAS]) questionnaires within 14 days of the procedures. RESULTS: A higher proportion of patients preferred the EG Scan (54.2%) vs the C-EGD (16.7%) (P<.001) and the EG Scan had a higher VAS score (7.2) vs the C-EGD (6.4) (P=.0004). No serious adverse events occurred. The EG Scan identified any length BE with a sensitivity value of 0.90 (95% CI, 0.83-0.96) and a specificity value of 0.91 (95% CI, 0.82-0.96). The EG Scan identified long segment BE with a sensitivity value of 0.95 and short segment BE with a sensitivity values of 0.87. CONCLUSION: In a prospective study, we found the EG Scan to be safe and to detect BE with higher than 90% sensitivity and specificity. A higher proportion of patients preferred the EG Scan to C-EGD. This device might be used as a clinic-based tool to screen populations at risk for BE. ISRCTN registry identifier: 70595405; ClinicalTrials.gov no: NCT02066233
Improvement over time in outcomes for patients undergoing endoscopic therapy for Barrett's oesophagus-related neoplasia: 6-year experience from the first 500 patients treated in the UK patient registry.
BACKGROUND: Barrett's oesophagus (BE) is a pre-malignant condition leading to oesophageal adenocarcinoma (OAC). Treatment of neoplasia at an early stage is desirable. Combined endoscopic mucosal resection (EMR) followed by radiofrequency ablation (RFA) is an alternative to surgery for patients with BE-related neoplasia. METHODS: We examined prospective data from the UK registry of patients undergoing RFA/EMR for BE-related neoplasia from 2008 to 2013. Before RFA, visible lesions were removed by EMR. Thereafter, patients had RFA 3-monthly until all BE was ablated or cancer developed (endpoints). End of treatment biopsies were recommended at around 12 months from first RFA treatment or when endpoints were reached. Outcomes for clearance of dysplasia (CR-D) and BE (CR-IM) at end of treatment were assessed over two time periods (2008-2010 and 2011-2013). Durability of successful treatment and progression to OAC were also evaluated. RESULTS: 508 patients have completed treatment. CR-D and CR-IM improved significantly between the former and later time periods, from 77% and 56% to 92% and 83%, respectively (p<0.0001). EMR for visible lesions prior to RFA increased from 48% to 60% (p=0.013). Rescue EMR after RFA decreased from 13% to 2% (p<0.0001). Progression to OAC at 12 months is not significantly different (3.6% vs 2.1%, p=0.51). CONCLUSIONS: Clinical outcomes for BE neoplasia have improved significantly over the past 6 years with improved lesion recognition and aggressive resection of visible lesions before RFA. Despite advances in technique, the rate of cancer progression remains 2-4% at 1 year in these high-risk patients. TRIAL REGISTRATION NUMBER: ISRCTN93069556
Risk stratification of Barrett's oesophagus using a non-endoscopic sampling method coupled with a biomarker panel: a cohort study
Background Barrett's oesophagus predisposes to adenocarcinoma. However, most patients with Barrett's oesophagus will not progress and endoscopic surveillance is invasive, expensive, and fraught by issues of sampling bias and the subjective assessment of dysplasia. We investigated whether a non-endoscopic device, the Cytosponge, could be coupled with clinical and molecular biomarkers to identify a group of patients with low risk of progression suitable for non-endoscopic follow-up. Methods In this multicentre cohort study (BEST2), patients with Barrett's oesophagus underwent the Cytosponge test before their surveillance endoscopy. We collected clinical and demographic data and tested Cytosponge samples for a molecular biomarker panel including three protein biomarkers (P53, c-Myc, and Aurora kinase A), two methylation markers (MYOD1 and RUNX3), glandular atypia, and TP53 mutation status. We used a multivariable logistic regression model to compute the conditional probability of dysplasia status. We selected a simple model with high classification accuracy and applied it to an independent validation cohort. The BEST2 study is registered with ISRCTN, number 12730505. Findings The discovery cohort consisted of 468 patients with Barrett's oesophagus and intestinal metaplasia. Of these, 376 had no dysplasia and 22 had high-grade dysplasia or intramucosal adenocarcinoma. In the discovery cohort, a model with high classification accuracy consisted of glandular atypia, P53 abnormality, and Aurora kinase A positivity, and the interaction of age, waist-to-hip ratio, and length of the Barrett's oesophagus segment. 162 (35%) of 468 of patients fell into the low-risk category and the probability of being a true non-dysplastic patient was 100% (99% CI 96–100) and the probability of having high-grade dysplasia or intramucosal adenocarcinoma was 0% (0–4). 238 (51%) of participants were classified as of moderate risk; the probability of having high-grade dysplasia was 14% (9–21). 58 (12%) of participants were classified as high-risk; the probability of having non-dysplastic endoscopic biopsies was 13% (5–27), whereas the probability of having high-grade dysplasia or intramucosal adenocarcinoma was 87% (73–95). In the validation cohort (65 patients), 51 were non-dysplastic and 14 had high-grade dysplasia. In this cohort, 25 (38%) of 65 patients were classified as being low-risk, and the probability of being non-dysplastic was 96·0% (99% CI 73·80–99·99). The moderate-risk group comprised 27 non-dysplastic and eight high-grade dysplasia cases, whereas the high-risk group (8% of the cohort) had no non-dysplastic cases and five patients with high-grade dysplasia. Interpretation A combination of biomarker assays from a single Cytosponge sample can be used to determine a group of patients at low risk of progression, for whom endoscopy could be avoided. This strategy could help to avoid overdiagnosis and overtreatment in patients with Barrett's oesophagus. Funding Cancer Research UK
Hemostatic powder TC-325 treatment of malignancy-related upper gastrointestinal bleeds: International registry outcomes
BACKGROUND AND AIM: Upper gastrointestinal tumors account for 5% of upper gastrointestinal bleeds. These patients are challenging to treat due to the diffuse nature of the neoplastic bleeding lesions, high rebleeding rates, and significant transfusion requirements. TC-325 (Cook Medical, North Carolina, USA) is a hemostatic powder for gastrointestinal bleeding. The aim of this study was to examine the outcomes of upper gastrointestinal bleeds secondary to tumors treated with Hemospray therapy. METHODS: Data were prospectively collected on the use of Hemospray from 17 centers. Hemospray was used during emergency endoscopy for upper gastrointestinal bleeds secondary to tumors at the discretion of the endoscopist as a monotherapy, dual therapy with standard hemostatic techniques, or rescue therapy. RESULTS: One hundred and five patients with upper gastrointestinal bleeds secondary to tumors were recruited. The median Blatchford score at baseline was 10 (interquartile range [IQR], 7-12). The median Rockall score was 8 (IQR, 7-9). Immediate hemostasis was achieved in 102/105 (97%) patients, 15% of patients had a 30-day rebleed, 20% of patients died within 30Â days (all-cause mortality). There was a significant improvement in transfusion requirements following treatment (PÂ <Â 0.001) when comparing the number of units transfused 3Â weeks before and after treatment. The mean reduction was one unit per patient. CONCLUSIONS: Hemospray achieved high rates of immediate hemostasis, with comparable rebleed rates following treatment of tumor-related upper gastrointestinal bleeds. Hemospray helped in improving transfusion requirements in these patients. This allows for patient stabilization and bridges towards definitive surgery or radiotherapy to treat the underlying tumor
- …