556 research outputs found

    Beam tests of the gas electron multiplier

    Get PDF
    We describe the results of systematic measurements, carried out with single and double GEM detectors with printed circuit read-out and having an active area 10x10 cm , both in the laboratory and in a high energy charged particles beam at CERN. Using fast analogue readout electronics, we demonstrate efficiencies for minimum ionizing particles close to 100%, with typical signal/noise ratios above 50 and up to 10 for the single and double GEM configuration, respectively, and a time resolution of 15 ns fwhm. Localization accuracies around 40 mm rms have been obtained for perpendicular tracks, degrading to 200 mm at 20° of incidence to the normal. Operated in a non-flammable gas mixture (argon-carbon dioxide), GEM detectors are robust, light and cheap to manufacture, and offer excellent performances and reliability suited for use in the harsh environments met at high luminosity colliders

    Effects of High Charge Densities in Multi-GEM Detectors

    Full text link
    A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed variations of the gain, of the ion back-flow, and of the pulse height spectra are explained in terms of the effects of the spatial distribution of positive ions and their movement throughout the amplification structure. The intrinsic dynamic character of the processes involved imposes the use of a non-standard simulation tool for the interpretation of the measurements. Computations done with a Finite Element Analysis software reproduce the observed behaviour of the detector. The impact of this detailed description of the detector in extreme conditions is multiple: it clarifies some detector behaviours already observed, it helps in defining intrinsic limits of the GEM technology, and it suggests ways to extend them.Comment: 5 pages, 6 figures, 2015 IEEE Nuclear Science Symposiu

    Aging measurements with the gas electron multiplier (GEM)

    Get PDF
    Continuing previous aging measurements with detectors based on the Gas Electron Multiplier (GEM), a 31Ă—3131\times 31cm2^2 triple-GEM detector, as used in the small area tracking of the COMPASS experiment at CERN, was investigated. With a detector identical to those installed in the experiment, long-term, high-rate exposures to 8.98.9keV X-ray radiation were performed to study its aging properties. In standard operation conditions, with Ar:CO2_2 (70:30) filling and operated at an effective gain of 8.5â‹…1038.5\cdot 10^3, no change in gain and energy resolution is observed after collecting a total charge of 7mC/mm2^2, corresponding to seven years of normal operation. This observation confirms previous results demonstrating the relative insensitivity of GEM detectors to aging, even when manufactured with common materials

    Optimisation of the Gas Electron Multiplier for high rate application

    Get PDF
    The construction and performance of large size GEM~detectors for the COMPASS~experiment is described. Based on the experience gained during the operation of these detectors in high rate muon, proton, and pion beams we discuss the suitability of their use in harsh radiation environments

    Charge Transfer Properties Through Graphene for Applications in Gaseous Detectors

    Get PDF
    Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical and electrical properties. Regarded as the thinnest and narrowest conductive mesh, it has drastically different transmission behaviours when bombarded with electrons and ions in vacuum. This property, if confirmed in gas, may be a definitive solution for the ion back-flow problem in gaseous detectors. In order to ascertain this aspect, graphene layers of dimensions of about 2x2cm2^2, grown on a copper substrate, are transferred onto a flat metal surface with holes, so that the graphene layer is freely suspended. The graphene and the support are installed into a gaseous detector equipped with a triple Gaseous Electron Multiplier (GEM), and the transparency properties to electrons and ions are studied in gas as a function of the electric fields. The techniques to produce the graphene samples are described, and we report on preliminary tests of graphene-coated GEMs.Comment: 4pages, 3figures, 13th Pisa Meeting on Advanced Detector

    New observations with the gas electron multiplier (GEM)

    Get PDF
    We describe recent measurements realized with the Gas Electron Multiplier (GEM) mesh added as pre-amplification element to a multiwire and a micro-strip chamber. Large, stable combined gains are obtained, with good uniformity and energy resolution, in a wide range of filling gases including non-flammable mixtures; coupled to a micro-strip plate, the pre-amplification element allows to maintain the high rate capability and resolution at considerably lower operating voltages, completely eliminating discharge problems. Charge gains are large enough to allow detection of signals in the ionization mode on the last element, permitting the use of a simple printed circuit as read-out electrode; two-dimensional read-out can then be easily implemented. The absence of charge multiplication in the last stage avoids charge build-up on the substrate and prevents ageing phenomena. A new generation of simple, reliable and cheap fast position sensitive detectors seems at hand

    The gas electron multiplier (GEM)

    Get PDF
    We describe operating priciples and results obtained with a new detector component: the Gas Electrons Multiplier (GEM). Consisting of a thin composite sheet with two metal layers separated by a thin insulator, and pierced by a regular matrix of open channels, the GEM electrode, inserted on the path of electrons in a gas detector, allows to transfer the charge with an amplification factor approaching ten. Uniform response and high rate capability are demonstrated. Coupled to another device, multiwire or micro-strip chamber, the GEM electrode permit to obtain higher gains or less critical operation; separation of the sensitive (conversion) volume and the detection volume has other advantages, as a built-in delay (useful for triggering purposes) and the possibility of applying high fields on the photo-cathode of ring imaging detectors to improve efficiency. Multiple GEM grids in the same gas volume allow to obtain large amplification factors in a succession of steps, leading to the realization of an effective gas-filled photomultiplier

    Further developments of the gas electron multiplier (GEM)

    Get PDF
    We describe the development and operation of the Gas Electron Multiplier, a thin insulating foil metal-clad on both sides and perforated by a regular pattern of small holes. The mesh can be incorporat ed in the gas volume of an active detector to provide a first amplification channel for electrons, or used as stand alone. We report on the basic properties of GEMs manufactured with different geometr ies and operated in several gas mixtures as well as on their long-term stability after accumulation of charge equivalent to several years of operation in high luminosity experiments. Optimized GEMs re ach gains close to 10000 at safe operating voltages, permitting the detection of ionizing tracks, without other amplifying elements, on a simple printed circuit board (PCB), opening new possibilities for detector design

    Two-dimensional readout of GEM detectors

    Get PDF
    The recently introduced Gas Electron Multiplier (GEM) permits the amplification of electrons released by ionizing radiation in a gas by factors approaching ten thousand, larger gains can be obtained combining two GEMs in cascade. We describe methods for implementing two- and three-dimensional projective localization of radiation, with sub-millimeter accuracy, making use of specially manufactured and patterned pick-up electrodes. Easy to implement and flexible in the choice of the readout geometry, the technology has the distinctive advantage of allowing all pick-up electrodes to be kept at ground potential, thus substantially improving the system simplicity and reliability. Preliminary results demonstrating the two-dimensional imaging capability of the devices are provided and discussed, as well as future perspectives of development

    Optimization of design and beam test of microstrip gas chambers

    Get PDF
    We describe recent experimental and theoretical work aimed at optimizing the geometry and the operation of micro-strip gas chambers in order to improve their performance and reliability. With the help of a simulation program, we have studied the mechanism of signal propagation and analyzed the effects on signal shape and size of resistivity of strips, grouping of biased strips and presence of a back-plane. Several detectors manufactured according to the results of the study and equipped with fast amplifiers have been installed in a test beam to study general operating characteristics, efficiency and localization accuracy; preliminary results of the data analysis are discussed
    • …