1,148 research outputs found

    What limits supercurrents in high temperature superconductors? A microscopic model of cuprate grain boundaries

    Full text link
    The interface properties of high-temperature cuprate superconductors have been of interest for many years, and play an essential role in Josephson junctions, superconducting cables, and microwave electronics. In particular, the maximum critical current achievable in high-Tc wires and tapes is well known to be limited by the presence of grain boundaries, regions of mismatch between crystallites with misoriented crystalline axes. In studies of single, artificially fabricated grain boundaries the striking observation has been made that the critical current Jc of a grain boundary junction depends exponentially on the misorientation angle. Until now microscopic understanding of this apparently universal behavior has been lacking. We present here the results of a microscopic evaluation based on a construction of fully 3D YBCO grain boundaries by molecular dynamics. With these structures, we calculate an effective tight-binding Hamiltonian for the d-wave superconductor with a grain boundary. The critical current is then shown to follow an exponential suppression with grain boundary angle. We identify the buildup of charge inhomogeneities as the dominant mechanism for the suppression of the supercurrent.Comment: 28 pages, 12 figure

    Acceleration of generalized hypergeometric functions through precise remainder asymptotics

    Full text link
    We express the asymptotics of the remainders of the partial sums {s_n} of the generalized hypergeometric function q+1_F_q through an inverse power series z^n n^l \sum_k c_k/n^k, where the exponent l and the asymptotic coefficients {c_k} may be recursively computed to any desired order from the hypergeometric parameters and argument. From this we derive a new series acceleration technique that can be applied to any such function, even with complex parameters and at the branch point z=1. For moderate parameters (up to approximately ten) a C implementation at fixed precision is very effective at computing these functions; for larger parameters an implementation in higher than machine precision would be needed. Even for larger parameters, however, our C implementation is able to correctly determine whether or not it has converged; and when it converges, its estimate of its error is accurate.Comment: 36 pages, 6 figures, LaTeX2e. Fixed sign error in Eq. (2.28), added several references, added comparison to other methods, and added discussion of recursion stabilit

    Altered visual feedback from an embodied avatar unconsciously influences movement amplitude and muscle activity

    Get PDF
    Evidence suggests that the sense of the position of our body parts can be surreptitiously deceived, for instance through illusory visual inputs. However, whether altered visual feedback during limb movement can induce substantial unconscious motor and muscular adjustments is not known. To address this question, we covertly manipulated virtual body movements in immersive virtual reality. Participants were instructed to flex their elbow to 90° while tensing an elastic band, as their virtual arm reproduced the same, a reduced (75°), or an amplified (105°) movement. We recorded muscle activity using electromyography, and assessed body ownership, agency and proprioception of the arm. Our results not only show that participants compensated for the avatar’s manipulated arm movement while being completely unaware of it, but also that it is possible to induce unconscious motor adaptations requiring significant changes in muscular activity. Altered visual feedback through body ownership illusions can influence motor performance in a process that bypasses awareness

    Using a virtual environment to assess cognition in the elderly

    Get PDF
    YesEarly diagnosis of Alzheimer’s disease (AD) is essential if treatments are to be administered at an earlier point in time before neurons degenerate to a stage beyond repair. In order for early detection to occur tools used to detect the disorder must be sensitive to the earliest of cognitive impairments. Virtual reality (VR) technology offers opportunities to provide products which attempt to mimic daily life situations, as much as is possible, within the computational environment. This may be useful for the detection of cognitive difficulties. We develop a virtual simulation designed to assess visuospatial memory in order to investigate cognitive function in a group of healthy elderly participants and those with a mild cognitive impairment. Participants were required to guide themselves along a virtual path to reach a virtual destination which they were required to remember. The preliminary results indicate that this virtual simulation has the potential to be used for detection of early AD since significant correlations of scores on the virtual environment with existing neuropsychological tests were found. Furthermore, the test discriminated between healthy elderly participants and those with a mild cognitive impairment (MCI)

    Observing Virtual Arms that You Imagine Are Yours Increases the Galvanic Skin Response to an Unexpected Threat

    Get PDF
    Multi-modal visuo-tactile stimulation of the type performed in the rubber hand illusion can induce the brain to temporarily incorporate external objects into the body image. In this study we show that audio-visual stimulation combined with mental imagery more rapidly elicits an elevated physiological response (skin conductance) after an unexpected threat to a virtual limb, compared to audio-visual stimulation alone. Two groups of subjects seated in front of a monitor watched a first-person perspective view of slow movements of two virtual arms intercepting virtual balls rolling towards the viewer. One group was instructed to simply observe the movements of the two virtual arms, while the other group was instructed to observe the virtual arms and imagine that the arms were their own. After 84 seconds the right virtual arm was unexpectedly “stabbed” by a knife and began “bleeding”. This aversive stimulus caused both groups to show a significant increase in skin conductance. In addition, the observation-with-imagery group showed a significantly higher skin conductance (p<0.05) than the observation-only group over a 2-second period shortly after the aversive stimulus onset. No corresponding change was found in subjects' heart rates. Our results suggest that simple visual input combined with mental imagery may induce the brain to measurably temporarily incorporate external objects into its body image

    Is my hand connected to my body? The impact of body continuity and arm alignment on the virtual hand illusion

    Get PDF
    When a rubber hand is placed on a table top in a plausible position as if part of a person"s body, and is stroked synchronously with the person"s corresponding hidden real hand, an illusion of ownership over the rubber hand can occur (Botvinick and Cohen 1998). A similar result has been found with respect to a virtual hand portrayed in a virtual environment, a virtual hand illusion (Slater et al. 2008). The conditions under which these illusions occur have been the subject of considerable study. Here we exploited the flexibility of virtual reality to examine four contributory factors: visuo-tactile synchrony while stroking the virtual and the real arms, body continuity, alignment between the real and virtual arms, and the distance between them. We carried out three experiments on a total of 32 participants where these factors were varied. The results show that the subjective illusion of ownership over the virtual arm and the time to evoke this illusion are highly dependent on synchronous visuo-tactile stimulation and on connectivity of the virtual arm with the rest of the virtual body. The alignment between the real and virtual arms and the distance between these were less important. It was found that proprioceptive drift was not a sensitive measure of the illusion, but was only related to the distance between the real and virtual arms

    The Human Touch: Skin Temperature During the Rubber Hand Illusion in Manual and Automated Stroking Procedures

    Get PDF
    Rohde M, Wold A, Karnath H-O, Ernst MO. The Human Touch: Skin Temperature During the Rubber Hand Illusion in Manual and Automated Stroking Procedures. PLoS ONE. 2013;8(11): e80688.A difference in skin temperature between the hands has been identified as a physiological correlate of the rubber hand illusion (RHI). The RHI is an illusion of body ownership, where participants perceive body ownership over a rubber hand if they see it being stroked in synchrony with their own occluded hand. The current study set out to replicate this result, i.e., psychologically induced cooling of the stimulated hand using an automated stroking paradigm, where stimulation was delivered by a robot arm (PHANToMTM force-feedback device). After we found no evidence for hand cooling in two experiments using this automated procedure, we reverted to a manual stroking paradigm, which is closer to the one employed in the study that first produced this effect. With this procedure, we observed a relative cooling of the stimulated hand in both the experimental and the control condition. The subjective experience of ownership, as rated by the participants, by contrast, was strictly linked to synchronous stroking in all three experiments. This implies that hand-cooling is not a strict correlate of the subjective feeling of hand ownership in the RHI. Factors associated with the differences between the two designs (differences in pressure of tactile stimulation, presence of another person) that were thus far considered irrelevant to the RHI appear to play a role in bringing about this temperature effect

    Community-based intervention to promote breast cancer awareness and screening: The Korean experience

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There are many differences in culture, community identity, community participation, and ownership between communities in Western and Asian countries; thus, it is difficult to adopt the results of community intervention studies from Western countries. In this study, we conducted a multicity, multicomponent community intervention trial to correct breast cancer myths and promote screening mammography for women living in an urban community in Korea.</p> <p>Methods</p> <p>A 6-month, 2-city community intervention trial was conducted. In the intervention city, 480 women were surveyed at baseline and 7 months later to evaluate the effects of the intervention program. Strategies implemented in the intervention city included community outreach and clinic and pharmacy-based in-reach strategies.</p> <p>Results</p> <p>This study showed a 20.4-percentage-point decrease in myths about the link between cancer and breast size, a 19.2-percentage-point decrease in myths concerning mammography costs, and a 14.1-percentage-point increase in intention to undergo screening mammography. We also saw a 23.4-percentage-point increase in the proportion of women at the action stage of the transtheoretical model in the intervention city. In the comparison city, smaller decreases and increases were observed.</p> <p>Conclusions</p> <p>Our study showed the value of an intervention study aimed at reducing belief in breast cancer myths in an urban community in Korea. The invention also made women more likely to undergo mammography in future.</p

    Acute pressure overload of the right ventricle. Comparison of two models of right-left shunt. Pulmonary artery to left atrium and right atrium to left atrium: experimental study

    Get PDF
    <p>Abtract</p> <p>Background</p> <p>In right ventricular failure (RVF), an interatrial shunt can relieve symptoms of severe pulmonary hypertension by reducing right ventricular preload and increasing systemic flow. Using a pig model to determine if a pulmonary artery - left atrium shunt (PA-LA) is better than a right atrial - left atrial shunt (RA-LA), we compared the hemodynamic effects and blood gases between the two shunts.</p> <p>Methods</p> <p>Thirty, male Large White pigs weighting in average 21.3 kg ± 0.7 (SEM) were divided into two groups (15 pigs per group): In group 1, banding of the pulmonary artery and a pulmonary artery to left atrium shunt with an 8 mm graft (PA-LA) was performed and in group 2 banding of the pulmonary artery and right atrial to left atrial shunt (RA-LA) with a similar graft was performed. Hemodynamic parameters and blood gases were measured from all cardiac chambers in 10 and 20 minutes, half and one hour interval from the baseline (30 min from the banding). Cardiac output and flow of at the left anterior descending artery was also monitored.</p> <p>Results</p> <p>In both groups, a stable RVF was generated. The PA-LA shunt compared to the RA-LA shunt has better hemodynamic performance concerning the decreased right ventricle afterload, the 4 fold higher mean pressure of the shunt, the better flow in left anterior descending artery and the decreased systemic vascular resistance. Favorable to the PA-LA shunt is also the tendency - although not statistically significant - in relation to central venous pressure, left atrial filling and cardiac output.</p> <p>Conclusion</p> <p>The PA-LA shunt can effectively reverse the catastrophic effects of acute RVF offering better hemodynamic characteristics than an interatrial shunt.</p
    corecore