6 research outputs found

    Isometric placement of the augmentation braid is not attained reliably in contemporary ACL suture repair

    No full text
    BACKGROUND: To assess if during arthroscopic braid-augmented ACL suture repair (ACLSR), the actual positions of the augmentation braids' tunnels corresponded with the positions of their intended and targeted isometric points, and to test the hypothesis that there would be no dispersion in actual positions of the augmentation braids' tunnels compared to their intended and targeted isometric points. METHODS: In 12 human cadaveric knees, the positions of the augmentation braids' tunnels and their intended and targeted isometric points relative to a femoral and tibial grid were analysed. Furthermore, vector length between these positions was calculated to assess the accuracy and precision of the augmentation braids' tunnel placement. RESULTS: There was dispersion for all of the augmentation braids' tunnel positions compared to their intended isometric points. The femoral and tibial vector lengths (mean ± SD (range)) were 2.9 ± 1.0 (1.1-4.1) and 7.1 ± 2.0 (3.2-9.8) mm respectively. CONCLUSION: In augmented ACLSR, with the ruptured ACL in situ, there was dispersion of the positions of the actual small diameter femoral and tibial augmentation braids' tunnels away from their desired isometric points. CLINICAL RELEVANCE: The extent of dispersion of the position of both the femoral and tibial tunnels away from their intended isometric positions may cause cyclic length changes with knee motion. An ACLSR with static braid augmentation will thus be vulnerable to cyclic stretching-out. The difficulty of obtaining an isometric tunnel combination for the small diameter augmentation braid may influence the clinician's choice between non-, static or dynamic augmented ACLSR techniques

    Dynamic augmentation restores anterior tibial translation in ACL suture repair: a biomechanical comparison of non-, static and dynamic augmentation techniques

    No full text
    PURPOSE: There is a lack of objective evidence investigating how previous non-augmented ACL suture repair techniques and contemporary augmentation techniques in ACL suture repair restrain anterior tibial translation (ATT) across the arc of flexion, and after cyclic loading of the knee. The purpose of this work was to test the null hypotheses that there would be no statistically significant difference in ATT after non-, static- and dynamic-augmented ACL suture repair, and they will not restore ATT to normal values across the arc of flexion of the knee after cyclic loading. METHODS: Eleven human cadaveric knees were mounted in a test rig, and knee kinematics from 0° to 90° of flexion were recorded by use of an optical tracking system. Measurements were recorded without load and with 89-N tibial anterior force. The knees were tested in the following states: ACL-intact, ACL-deficient, non-augmented suture repair, static tape augmentation and dynamic augmentation after 10 and 300 loading cycles. RESULTS: Only static tape augmentation and dynamic augmentation restored ATT to values similar to the ACL-intact state directly postoperation, and maintained this after cyclic loading. However, contrary to dynamic augmentation, the ATT after static tape augmentation failed to remain statistically less than for the ACL-deficient state after cyclic loading. Moreover, after cyclic loading, ATT was significantly less with dynamic augmentation when compared to static tape augmentation. CONCLUSION: In contrast to non-augmented ACL suture repair and static tape augmentation, only dynamic augmentation resulted in restoration of ATT values similar to the ACL-intact knee and decreased ATT values when compared to the ACL-deficient knee immediately post-operation and also after cyclic loading, across the arc of flexion, thus allowing the null hypotheses to be rejected. This may assist healing of the ruptured ACL. Therefore, this study would support further clinical evaluation of dynamic augmentation of ACL repair
    corecore