74 research outputs found

    Investigation of the limits of nanoscale filopodial interactions

    Get PDF
    Mesenchymal stem cells are sensitive to changes in feature height, order and spacing. We had previously noted that there was an inverse relationship between osteoinductive potential and feature height on 15-, 55- and 90 nm-high titania nanopillars, with 15 nm-high pillars being the most effective substrate at inducing osteogenesis of human mesenchymal stem cells. The osteoinductive effect was somewhat diminished by decreasing the feature height to 8 nm, however, which suggested that there was a cut-off point, potentially associated with a change in cell–nanofeature interactions. To investigate this further, in this study, a scanning electron microscopy/three-dimensional scanning electron microscopy approach was used to examine the interactions between mesenchymal stem cells and the 8 and 15 nm nanopillared surfaces. As expected, the cells adopted a predominantly filopodial mode of interaction with the 15 nm-high pillars. Interestingly, fine nanoscale membrane projections, which we have termed ‘nanopodia,’ were also employed by the cells on the 8 nm pillars, and it seems that this is analogous to the cells ‘clinging on with their fingertips’ to this scale of features

    In vitro analyses of the toxicity, immunological, and gene expression effects of cobalt-chromium alloy wear debris and Co ions derived from metal-on-metal hip implants

    Get PDF
    Joint replacement has proven to be an extremely successful and cost-effective means of relieving arthritic pain and improving quality of life for recipients. Wear debris-induced osteolysis is, however, a major limitation and causes orthopaedic implant aseptic loosening, and various cell types including macrophages, monocytes, osteoblasts, and osteoclasts, are involved. During the last few years, there has been increasing concern about metal-on-metal (MoM) hip replacements regarding adverse reactions to metal debris associated with the MoM articulation. Even though MoM-bearing technology was initially aimed to extend the durability of hip replacements and to reduce the requirement for revision, they have been reported to release at least three times more cobalt and chromium ions than metal-on-polyethylene (MoP) hip replacements. As a result, the toxicity of metal particles and ions produced by bearing surfaces, both locally in the periprosthetic space and systemically, became a concern. Several investigations have been carried out to understand the mechanisms responsible for the adverse response to metal wear debris. This review aims at summarising in vitro analyses of the toxicity, immunological, and gene expression effects of cobalt ions and wear debris derived from MoM hip implants

    Obesity is associated with higher complication rates in revision total hip arthroplasty

    Get PDF
    We examined differences in complication rates between obese and non-obese patients undergoing revision total hip arthroplasty. Sixty-five patients with a BMI ≥30 kg/m2 and 54 patients with a BMI of <30 kg/m2 were identified. Obese patients were 2.5 times more likely to suffer a complication than non-obese (38.4% cf 14.8%, p = 0.02). Obese patients were more likely to experience dislocation, leg length discrepancy, fracture, implant loosening, infection and pulmonary embolus. The obese group had a significantly higher revision rate (12.3% cf 1.8%, p = 0.039). Obese patients should be counselled pre-operatively on their elevated risk

    Elective hip arthroplasty rates and related complications in people with diabetes mellitus

    Get PDF
    Background and Aims: Diabetes mellitus (DM), poor glycaemic control and raised body mass index (BMI) have been associated with postoperative complications in arthroplasty, although the relative importance of these factors is unclear. We describe the prevalence of DM in elective hip arthroplasty in a UK centre, and evaluate the impact of these factors. Methods: We analysed retrospective data for DM patients undergoing arthroplasty over a 6-year period and compared with non-diabetic matched controls (1 DM patient: 5 controls). DM was present in 5.7% of hip arthroplasty patients (82/1443). Results: Postoperative complications occurred in 12.2% of DM patients versus 12.9% of controls (p = 1.000); surgical complications were present in 6.1% of those with DM and 2.4% of controls (p = 0.087), while medical complications occurred in 8.5% of DM patients versus 10.7% of controls (p = 0.692). Complications developed in 23.1% of DM patients with poor glycaemic control (HbA1c &gt; 53 mmol/mol) versus 9.8% with good control (p = 0.169). In DM patients and controls combined, complications occurred in 16.3% of obese patients versus 10.0% of non-obese patients (p = 0.043). In the DM cohort, 13.7% of overweight patients had complications versus 0% with a normal or low BMI (p = 0.587). Conclusions: DM rates were lower than expected, and glycaemic control was good. Overall complication rates were unrelated to the presence of DM or to glycaemic control, although surgical complications were observed more frequently in those with DM and poor glycaemic control was uncommon within our cohort. Complications were more frequent in those with a higher BMI. Whether some patients with DM but without an increased risk of complications are currently being excluded from surgery requires exploration

    Bioengineered niches that recreate physiological extracellular matrix organisation to support long-term haematopoietic stem cells

    Get PDF
    Long-term reconstituting haematopoietic stem cells (LT-HSCs) are used to treat blood disorders via stem cell transplantation. The very low abundance of LT-HSCs and their rapid differentiation during in vitro culture hinders their clinical utility. Previous developments using stromal feeder layers, defined media cocktails, and bioengineering have enabled HSC expansion in culture, but of mostly short-term HSCs and progenitor populations at the expense of naive LT-HSCs. Here, we report the creation of a bioengineered LT-HSC maintenance niche that recreates physiological extracellular matrix organisation, using soft collagen type-I hydrogels to drive nestin expression in perivascular stromal cells (PerSCs). We demonstrate that nestin, which is expressed by HSC-supportive bone marrow stromal cells, is cytoprotective and, via regulation of metabolism, is important for HIF-1α expression in PerSCs. When CD34+ve HSCs were added to the bioengineered niches comprising nestin/HIF-1α expressing PerSCs, LT-HSC numbers were maintained with normal clonal and in vivo reconstitution potential, without media supplementation. We provide proof-of-concept that our bioengineered niches can support the survival of CRISPR edited HSCs. Successful editing of LT-HSCs ex vivo can have potential impact on the treatment of blood disorders

    Nanopit-induced osteoprogenitor cell differentiation: the effect of nanopit death

    Get PDF
    We aimed to assess osteogenesis in osteoprogenitor cells by nanopits and to assess optimal feature depth. Topographies of depth 80 nm, 220 nm and 333 nm were embossed onto polycaprolactone (PCL) discs. Bone marrow-derived mesenchymal stromal cells were seeded onto PCL discs, suspended in media and incubated. Samples were fixed after three and 28 days. Cells were stained for the adhesion molecule vinculin and the osteogenic transcription factor RUNX2 after three days. Adhesion was lowest on planar controls and it was the shallowest, 80 nm deep pits that supported optimal adhesion formation. 80 nm and 220 nm deep pits induced most RUNX2 accumulation. After 28 days, osteocalcin and osteopontin expression were used as markers of osteoblastic differentiation. 220 nm deep pits produced cells with the highest concentrations of osteopontin and osteocalcin. All topographies induced higher expression levels than controls. We demonstrated stimulation of osteogenesis in a heterogeneous population of mesenchymal stromal cells. All nanopit depths gave promising results with an optimum depth of 220 nm after 28 days. Nanoscale modification of implant surfaces could optimise fracture union or osteointergration

    Proceedings of the United Kingdom Periprosthetic Joint Infection Meeting 2022: Fracture-Related Infection Session

    No full text
    Implant-related infections represent a relatively common and significant challenge in the surgical management of musculoskeletal trauma patients. The third United Kingdom Periprosthetic Joint Infection (UK PJI) Meeting convened in Glasgow on 1 April 2022, and brought together over 180 delegates, representing orthopaedics, infectious diseases, microbiology, plastic surgery, anaesthetics, and allied health professions, including pharmacy and specialist nurses. The meeting comprised a plenary session for all delegates, and separate breakout sessions for fracture-related infection (FRI) and arthroplasty. The UK PJI working group prepared consensus statements in advance of each session, based upon topics that were discussed at previous meetings, and delegates engaged in an anonymous electronic voting process. This article presents the findings of the FRI session, and examines each consensus topic within the context of the contemporary literature

    The Tribology of Explanted Hip Resurfacings Following Early Fracture of the Femur

    No full text
    A recognized issue related to metal-on-metal hip resurfacings is early fracture of the femur. Most theories regarding the cause of fracture relate to clinical factors but an engineering analysis of failed hip resurfacings has not previously been reported. The objective of this work was to determine the wear volumes and surface roughness values of a cohort of retrieved hip resurfacings which were removed due to early femoral fracture, infection and avascular necrosis (AVN). Nine resurfacing femoral heads were obtained following early fracture of the femur, a further five were retrieved due to infection and AVN. All fourteen were measured for volumetric wear using a co-ordinate measuring machine. Wear rates were then calculated and regions of the articulating surface were divided into “worn” and “unworn”. Roughness values in these regions were measured using a non-contacting profilometer. The mean time to fracture was 3.7 months compared with 44.4 months for retrieval due to infection and AVN. Average wear rates in the early fracture heads were 64 times greater than those in the infection and AVN retrievals. Given the high wear rates of the early fracture components, such wear may be linked to an increased risk of femoral neck fracture

    Biomimetic microtopography to enhance osteogenesis <i>in vitro</i>

    No full text
    Biomimicry is being used in the next generation of biomaterials. Tuning material surface features such as chemistry, stiffness and topography allow the control of cell adhesion, proliferation, growth and differentiation. Here, microtopographical features with nanoscale depths, similar in scale to osteoclast resorption pits, were used to promote &lt;i&gt;in&lt;/i&gt; vitro bone formation in basal medium. Primary human osteoblasts were used to represent an orthopaedically relevant cell type and analysis of adhesions, cytoskeleton, osteospecific proteins (phospho-Runx2 and osteopontin) and mineralisation (alizarin red) was performed. The results further demonstrate the potential for biomimicry in material design and show that the osteoblast response can be tuned from changes in feature size

    Grooved surface topography alters matrix-metalloproteinase production by human fibroblasts

    No full text
    Extracellular matrix (ECM) remodelling is an essential physiological process in which matrix-metalloproteinases (MMPs) have a key role. Manipulating the manner in which cells produce MMPs and ECMs may enable the creation of a desired tissue type, i.e. effect repair, or the prevention of tissue invasion (e.g. metastasis). The aim of this project was to determine if culturing fibroblasts on grooved topography altered collagen deposition or MMP production. Human fibroblasts were seeded on planar or grooved polycaprolactone substrates (grooves were 12.5 µm wide with varying depths of 240 nm, 540 nm or 2300 nm). Cell behaviour and collagen production were studied using fluorescence microscopy and the spent culture medium was assessed using gel zymography to detect MMPs. Total collagen deposition was high on the 240 nm deep grooves, but decreased as the groove depth increased, i.e. as cell contact guidance decreased. There was an increase in gelatinase on the 2300 nm deep grooved topography and there was a difference in the temporal expression of MMP-3 observed on the planar surface compared to the 540 nm and 2300 nm topographies. These results show that topography can alter collagen and MMP production. A fuller understanding of these processes may permit the design of surfaces tailored to tissue regeneration e.g. tendon repair