36,568 research outputs found

    Technical and economic aspects of hydrogen storage in metal hydrides

    Get PDF
    The recovery of hydrogen from such metal hydrides as LiH, MgH2, TiH2, CaH2 and FeTiH compounds is studied, with the aim of evaluating the viability of the technique for the storage of hydrogen fuel. The pressure-temperature dependence of the reactions, enthalpies of formation, the kinetics of the hydrogen absorption and desorption, and the mechanical and chemical stability of the metal hydrides are taken into account in the evaluation. Economic aspects are considered. Development of portable metal hydride hydrogen storage reservoirs is also mentioned

    Abundances of Na, Sc, Cr, Mn, Fe, Co, and Cu in chondrules, Na, Mn, and Cu in meteorites, and In in meteoritic and terrestrial matter Quarterly progress report, 1 Dec. 1965 - 28 Feb. 1966

    Get PDF
    Element abundance in chondrules and meteorites measured by instrumental neutron activation analysis, and indium behavior in chondrite

    Abundances of trace elements Na, Sc, Cr, Mn, Fe, Co, and Cu in chondrules and meteorites in IN meteorites and terrestrial matter and U in type I carbonaceous chondrites Quarterly progress report, 1 Mar. - 15 Jun. 1966

    Get PDF
    Abundances of sodium, scandium, chromium, iron, manganese, cobalt, copper, indium, and uranium in chondrules, chondrites, and meteorites determined by neutron activation analysi

    Research on elemental abundances in meteoritic and terrestrial matter Summary progress report, 1 Sep. 1964 - 31 Aug. 1965

    Get PDF
    Element abundances determined by instrumental neutron activation analysis technique in individual chondrules separated from certain chondritic meteorite

    Ultraviolet corona detection sensor study

    Get PDF
    The feasibility of detecting electrical corona discharge phenomena in a space simulation chamber via emission of ultraviolet light was evaluated. A corona simulator, with a hemispherically capped point to plane electrode geometry, was used to generate corona glows over a wide range of pressure, voltage, current, electrode gap length and electrode point radius. Several ultraviolet detectors, including a copper cathode gas discharge tube and a UV enhanced silicon photodiode detector, were evaluated in the course of the spectral intensity measurements. The performance of both silicon target vidicons and silicon intensified target vidicons was evaluated analytically using the data generated by the spectroradiometer scans and the performance data supplied by the manufacturers
    corecore