35 research outputs found

    Velocity-selective direct frequency-comb spectroscopy of atomic vapors

    Get PDF
    We present an experimental and theoretical investigation of two-photon direct frequency-comb spectroscopy performed through velocity-selective excitation. In particular, we explore the effect of repetition rate on the 5S1/2→5D3/2,5/2\textrm{5S}_{1/2}\rightarrow \textrm{5D}_{3/2, 5/2} two-photon transitions excited in a rubidium atomic vapor cell. The transitions occur via step-wise excitation through the 5P1/2,3/2\textrm{5P}_{1/2, 3/2} states by use of the direct output of an optical frequency comb. Experiments were performed with two different frequency combs, one with a repetition rate of ≈925\approx 925 MHz and one with a repetition rate of ≈250\approx 250 MHz. The experimental spectra are compared to each other and to a theoretical model.Comment: 10 pages, 7 figure

    Assessing neurosky's usability to detect attention levels in an assessment exercise

    Get PDF
    This paper presents the results of a usability evaluation of the NeuroSky's MindSet (MS). Until recently most Brain Computer Interfaces (BCI) have been designed for clinical and research purposes partly due to their size and complexity. However, a new generation of consumer-oriented BCI has appeared for the video game industry. The MS, a headset with a single electrode, is based on electro-encephalogram readings (EEG) capturing faint electrical signals generated by neural activity. The electrical signal across the electrode is measured to determine levels of attention (based on Alpha waveforms) and then translated into binary data. This paper presents the results of an evaluation to assess the usability of the MS by defining a model of attention to fuse attention signals with user-generated data in a Second Life assessment exercise. The results of this evaluation suggest that the MS provides accurate readings regarding attention, since there is a positive correlation between measured and self-reported attention levels. The results also suggest there are some usability and technical problems with its operation. Future research is presented consisting of the definition a standardized reading methodology and an algorithm to level out the natural fluctuation of users' attention levels if they are to be used as inputs

    Photovoltaic retinal prosthesis : implant fabrication and performance

    No full text
    The objective of this work is to develop and test a photovoltaic retinal prosthesis for restoring sight to patients blinded by degenerative retinal diseases. A silicon photodiode array for subretinal stimulation has been fabricated by a silicon-integrated-circuit/MEMS process. Each pixel in the two-dimensional array contains three series-connected photodiodes, which photovoltaically convert pulsed near-infrared light into bi-phasic current to stimulate nearby retinal neurons without wired power connections. The device thickness is chosen to be 30 µm to absorb a significant portion of light while still being thin enough for subretinal implantation. Active and return electrodes confine current near each pixel and are sputter coated with iridium oxide to enhance charge injection levels and provide a stable neural interface. Pixels are separated by 5 µm wide trenches to electrically isolate them and to allow nutrient diffusion through the device. Three sizes of pixels (280, 140 and 70 µm) with active electrodes of 80, 40 and 20 µm diameter were fabricated. The turn-on voltages of the one-diode, two-series-connected diode and three-series-connected diode structures are approximately 0.6, 1.2 and 1.8 V, respectively. The measured photo-responsivity per diode at 880 nm wavelength is ~0.36 A W−1, at zero voltage bias and scales with the exposed silicon area. For all three pixel sizes, the reverse-bias dark current is sufficiently low (<100 pA) for our application. Pixels of all three sizes reliably elicit retinal responses at safe near-infrared light irradiances, with good acceptance of the photodiode array in the subretinal space. The fabricated device delivers efficient retinal stimulation at safe near-infrared light irradiances without any wired power connections, which greatly simplifies the implantation procedure. Presence of the return electrodes in each pixel helps to localize the current, and thereby improves resolution
    corecore