699 research outputs found

    Utilization of translesional hemodynamics: comparison of pressure and flow methods in stenosis assessment in patie

    Get PDF
    Aim of this study is the assessment of feasibility and clinical usefulness of a new index of stenosis severity, the slope of the instantaneous transstenotic pressure gradient/velocity relationship. Twenty-one patients scheduled for percutaneous revascularization procedures were studied with simultaneous measurement of poststenotic coronary pressure and flow velocity, in basal condition and during maximal hyperemia induced with intracoronary papaverine. Reliable measurements of the transstenotic pressure gradient/velocity relationship could be obtained in 11 patients. In 64% of the cases, a quadratic equation showed the best fit for the data. Steeper increases of the transstenotic pressure gradient at any given velocity increase were observed in the lesions with the smallest cross-sectional area measured with quantitative angiography. A comparison of this new index with coronary flow reserve, maximal hyperemic velocity, stenosis flow reserve derived from quantitative angiography, basal and hyperemic transstenotic pressure gradient and fractional flow reserve is presented and the relative merits of all these parameters are discussed. This pilot experience suggests that the instantaneous relationship between pressure gradient and flow velocity changes during the cardiac cycle can accurately characterize the stenosis hemodynamics in the catheterization laboratory

    Response of conductance and resistance coronary vessels to scalar concentrations of acetylcholine: Assessment with quantitative angiography and intracoronary Doppler echography in 29 patients with coronary artery disease

    Get PDF
    Abnormal vasoreactivity of the large conductance arteries has been observed in the presence of impaired endothelial function. More recently, experimental and clinical reports have shown that in early coronary atherosclerosis the impairment of the endothelium-mediated vasodilatation also involves the resistance arteries. The aim of this study is the correlation of endothelium-dependent vasodilatation of conductance and resistance vessels in coronary arteries without significant stenoses. In 29 patients (aged 57 +/- 9 years, 24 men and 5 women) undergoing coronary angioplasty, a Doppler guide wire and a perfusion catheter were introduced into the proximal segment of an artery with less than 30% diameter stenosis. Selective infusions of papaverine (bolus of 7 mg), acetylcholine (continuous infusion of 0.036, 0.36, and 3.6 micrograms/ml at a flow rate of 2 ml/min), and isosorbide dinitrate (bolus of 3 mg) were sequentially performed. Heart rate, aortic blood pressure, and blood flow velocity were continuously measured. Mean cross-sectional areas of a proximal and a distal arterial segment were measured in baseline conditions, at the end of each infusion of acetylcholine, and at the peak effect of isosorbide dinitrate with quantitative angiography (CAAS System; Pie Medical Data, Maastricht, The Netherlands). Coronary blood flow was calculated from the time-averaged flow velocity and the cross-sectional area at the site of the Doppler sample volume. Coronary flow resistance was calculated as mean aortic pressure divided by coronary flow. All of the concentrations of acetylcholine induced a significant vasoconstriction of the studied artery. At the maximal concentration of acetylcholine all but three patients (90%) showed a reduction of cross-sectional area (-24% +/- 20% and -22% +/- 20% for the proximal and distal segments, respectively, p < 0.00001). Flow velocity showed a significant increase only with the two highest concentrations of acetylcholine. The maximal concentration induce

    Affecting surface chirality via multicomponent adsorption of chiral and achiral molecules

    Get PDF
    Here we report on the apparent reduction in surface chirality upon co-assembling a chiral and achiral molecule into a physisorbed self-assembled monolayer at the liquid/solid interface as revealed by scanning tunneling microscopy (STM). Chiral OPV with achiral thymine gives rise to surface-confined supramolecular diastereomers

    Adjustment method for mechanical Boston scientific corporation 30 MHz intravascular ultrasound catheters connected to a Clearview console. Mechanical 30 MHz IVUS catheter adjustment.

    Get PDF
    Intracoronary ultrasound (ICUS) is often used in studies evaluating new interventional techniques. It is important that quantitative measurements performed with various ICUS imaging equipment and materials are comparable. During evaluation of quantitative coronary ultrasound (QCU) software, it appeared that Boston Scientific Corporation (BSC) 30 MHz catheters connected to a Clearview ultrasound console showed smaller dimensions of an in vitro phantom model than expected. In cooperation with the manufacturer the cause of this underestimation was determined, which is described in this paper, and the QCU software was extended with an adjustment. Evaluation was performed by performing in vitro measurements on a phantom model consisting of four highly accurate steel rings (perfect reflectors) with diameters of 2, 3, 4 and 5 mm. Relative differences (unadjusted) of the phantom were respectively: 15.92, 13.01, 10.10 and 12.23%. After applying the adjustment: -0.96, -1.84, -1.35 and -1.43%. In vivo measurements were performed on 24 randomly selected ICUS studies. These showed differences for not adjusted vs. adjusted measurements of lumen-, vessel- and plaque volumes of -10.1 +/- 1.5, -6.7 +/- 0.9 and -4.4 +/- 0.6%. An off-line adjustment formula was derived and applied on previous numerical QCU output data showing relative differences for lumen- and vessel volumes of 0.36 +/- 0.51 and 0.13 +/- 0.31%. 30 MHz BSC catheters connected to a Clearview ultrasound console underestimate vessel dimensions. This can retrospectively be adjusted within QCU software as well as retrospectively on numerical QCU data using a mathematical model

    The “Long‐Sheath” Technique in Percutaneous Aortic Balloon Valvuloplasty

    Get PDF
    A new 100 cm long 16.5 French valvuloplasty introducer was used in 12 consecutive patients (mean age 73 years, five males and seven females) undergoing aortic balloon valvuloplasty for severe aortic stenosis. The long‐sheath was introduced into the ascending aorta along the stiff part of an exchange guidewire. The valvuloplasty procedure, which included a complete diagnostic catheterization in three patients, lasted 113 ± 47 min (211 ± 81 min in the previous 18 procedures performed with a conventional approach, P < 0.05). Introduction of balloon catheters (3 × 12 mm trefoil balloon in the 12 cases and 2 × 19 mm bifoil balloon in 2 of these cases) was possible in all patients and an increased stability of the balloon during inflation was observed. No systemic embolization or vascular complications occurred at the puncture site. The long‐sheath technique appears to be a valuable adjunct for aortic valvuloplasty in that it provides easier and quicker access for even the largest balloons and additional support and stability during balloon inflation. In our experience, this reduced the practical difficulties and the duration of the procedure. Copyrigh

    Maximal blood flow velocity in severe coronary stenosis measured with a doppler guidewire. Limitations for the application of the continuity equation in the assessment of stenosis severity

    Get PDF
    In vitro and animal experiments have shown that the severity of coronary stenoses can be assessed using the continuity equation if the maximal blood flow velocity of the stenotic jet is measured. The large diameter and the low range of velocities measurable without frequency aliasing with the conventional intracoronary Doppler catheters precluded the clinical application of this method for hemodynamically significant coronary stenoses in humans. This article reports the results obtained using a 12 MHz steerable angioplasty guidewire in a consecutive se
    • 

    corecore