1,193 research outputs found

    On the electrical double layer contribution to the interfacial tension of protein crystals

    Full text link
    We study the electrical double layer at the interface between a protein crystal and a salt solution or a dilute solution of protein, and estimate the double layer's contribution to the interfacial tension of this interface. This contribution is negative and decreases in magnitude with increasing salt concentration. We also consider briefly the interaction between a pair of protein surfaces.Comment: 6 pages, 3 figures, revtex

    The power of VNA-driven quasi-optics to sense group molecular action in condensed phase systems

    Get PDF
    © © 20xx IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.The authors would like to thank the Engineering and Physical Sciences Research Council (EPSRC, UK) for generous support (EP/1014845)

    Accurate determination of terahertz optical constants by vector network analyzer of Fabry-Perot response

    Get PDF
    This paper was published in Optics Letters and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://dx.doi.org/10.1364/OL.38.005438. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law.We present a method based on a Fabry-Perot model to efficiently and accurately estimate optical constants of wafer samples in transmission-only measurements performed by a vector network analyzer (VNA). The method is demonstrated on two separate wafer samples: one of silicon and the other of polymethylmethacrylate. Results show that the method can not only acquire optical constants accurately and simply over a broad frequency domain but also overcome the limitations of calculation for dispersive and lossy materials to which existing methods are susceptible, such as those based on VNA-driven quasi-optical transmissometers and terahertz time-domain spectrometry

    Electroneutrality and Phase Behavior of Colloidal Suspensions

    Full text link
    Several statistical mechanical theories predict that colloidal suspensions of highly charged macroions and monovalent microions can exhibit unusual thermodynamic phase behavior when strongly deionized. Density-functional, extended Debye-H\"uckel, and response theories, within mean-field and linearization approximations, predict a spinodal phase instability of charged colloids below a critical salt concentration. Poisson-Boltzmann cell model studies of suspensions in Donnan equilibrium with a salt reservoir demonstrate that effective interactions and osmotic pressures predicted by such theories can be sensitive to the choice of reference system, e.g., whether the microion density profiles are expanded about the average potential of the suspension or about the reservoir potential. By unifying Poisson-Boltzmann and response theories within a common perturbative framework, it is shown here that the choice of reference system is dictated by the constraint of global electroneutrality. On this basis, bulk suspensions are best modeled by density-dependent effective interactions derived from a closed reference system in which the counterions are confined to the same volume as the macroions. Linearized theories then predict bulk phase separation of deionized suspensions only when expanded about a physically consistent (closed) reference system. Lower-dimensional systems (e.g., monolayers, small clusters), depending on the strength of macroion-counterion correlations, may be governed instead by density-independent effective interactions tied to an open reference system with counterions dispersed throughout the reservoir, possibly explaining observed structural crossover in colloidal monolayers and anomalous metastability of colloidal crystallites.Comment: 12 pages, 5 figures. Discussion clarified, references adde

    Efficiency and spectrum evaluation of terahertz photoconductive antenna array based on GaAs substrates

    Get PDF
    © 2014 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.Terahertz photoconductive antenna arrays with interdigitated electrodes are laid down on GaAs substrates in which different geometries are assessed for their ability to enhance performance of a time-domain spectrometer (TDS) system

    Mismatch-based delayed thrombolysis: a meta-analysis

    Get PDF
    <p><b>Background and Purpose</b>: Clinical benefit from thrombolysis is reduced as stroke onset to treatment time increases. The use of "mismatch" imaging to identify patients for delayed treatment has face validity and has been used in case series and clinical trials. We undertook a meta-analysis of relevant trials to examine whether present evidence supports delayed thrombolysis among patients selected according to mismatch criteria.</p> <p><b>Methods</b>: We collated outcome data for patients who were enrolled after 3 hours of stroke onset in thrombolysis trials and had mismatch on pretreatment imaging. We selected the trials on the basis of a systematic search of the Web of Knowledge. We compared favorable outcome, reperfusion and/or recanalization, mortality, and symptomatic intracerebral hemorrhage between the thrombolyzed and nonthrombolyzed groups of patients and the probability of a favorable outcome among patients with successful reperfusion and clinical findings for 3 to 6 versus 6 to 9 hours from poststroke onset. Results are expressed as adjusted odds ratios (a-ORs) with 95% CIs. Heterogeneity was explored by test statistics for clinical heterogeneity, I2 (inconsistency), and L’Abbé plot.</p> <p><b>Results</b>: We identified articles describing the DIAS, DIAS II, DEDAS, DEFUSE, and EPITHET trials, giving a total of 502 mismatch patients thrombolyzed beyond 3 hours. The combined a-ORs for favorable outcomes were greater for patients who had successful reperfusion (a-OR=5.2; 95% CI, 3 to 9; I2=0%). Favorable clinical outcome was not significantly improved by thrombolysis (a-OR=1.3; 95% CI, 0.8 to 2.0; I2=20.9%). Odds for reperfusion/recanalization were increased among patients who received thrombolytic therapy (a-OR=3.0; 95% CI, 1.6 to 5.8; I2=25.7%). The combined data showed a significant increase in mortality after thrombolysis (a-OR=2.4; 95% CI, 1.2 to 4.9; I2=0%), but this was not confirmed when we excluded data from desmoteplase doses that were abandoned in clinical development (a-OR=1.6; 95% CI, 0.7 to 3.7; I2=0%). Symptomatic intracerebral hemorrhage was significantly increased after thrombolysis (a-OR=6.5; 95% CI, 1.2 to 35.4; I2=0%) but not significant after exclusion of abandoned doses of desmoteplase (a-OR=5.4; 95% CI, 0.9 to 31.8; I2=0%).</p> <p><b>Conclusions</b>: Delayed thrombolysis amongst patients selected according to mismatch imaging is associated with increased reperfusion/recanalization. Recanalization/reperfusion is associated with improved outcomes. However, delayed thrombolysis in mismatch patients was not confirmed to improve clinical outcome, although a useful clinical benefit remains possible. Thrombolysis carries a significant risk of symptomatic intracerebral hemorrhage and possibly increased mortality. Criteria to diagnose mismatch are still evolving. Validation of the mismatch selection paradigm is required with a phase III trial. Pending these results, delayed treatment, even according to mismatch selection, cannot be recommended as part of routine care.</p&gt

    The power of VNA-driven quasi-optics to sense group molecular action in condensed phase systems

    Get PDF
    © 2014 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.The versatility for quasi-optical circuits, driven by modern vector network analysers, is demonstrated for the purpose of low energy (meV) coherent spectroscopy. One such example is shown applied to the curing dynamics of a non-mercury-based dental cement. This highlights the special place the methodology holds as a `soft-probe' to reveal the time-resolved energetics of condensed phased systems as they self-organise to adopt their low energy state

    Bayesian analysis of quasar lightcurves with a running optimal average : new time delay measurements of COSMOGRAIL gravitationally lensed quasars

    Get PDF
    Funding: KH and JVHS acknowledge support from UK Science and Technology Facilities Council grant ST/R00824/1.We present a new method of modelling time-series data based on the running optimal average (ROA). By identifying the effective number of parameters for the ROA model, in terms of the shape and width of its window function and the times and accuracies of the data, we enable a Bayesian analysis, optimising the ROA width, along with other model parameters, by minimising the Bayesian Information Criterion (BIC) and sampling joint posterior parameter distributions using MCMC methods. For analysis of quasar lightcurves, our implementation of ROA modelling can measure time delays among lightcurves at different wavelengths or from different images of a lensed quasar and, in future work, be used to inter-calibrate lightcurve data from different telescopes and estimate the shape and thus the power-density spectrum of the lightcurve. Our noise model implements a robust treatment of outliers and error-bar adjustments to account for additional variance or poorly-quantified uncertainties. Tests with simulated data validate the parameter uncertainty estimates. We compare ROA delay measurements with results from cross-correlation and from JAVELIN, which models lightcurves with a prior on the power-density spectrum. We analyse published COSMOGRAIL lightcurves of multi-lensed quasar lightcurves and present the resulting measurements of the inter-image time delays and detection of microlensing effects.PostprintPeer reviewe
    corecore