1,641 research outputs found

    Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors

    Get PDF
    We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allow the location of the interaction to be determined with ≲ 1mm resolution at 30 keV. Using this position information, variations in the detector response with position can be removed, and an energy resolution of σ_E = 0.55 keV at 30 keV was measured. Since MKIDs can be fabricated from a single deposited film and are naturally multiplexed in the frequency domain, this technology can be extended to provide highly pixelized athermal phonon sensors for ∼1 kg scale detector elements. Such high-resolution, massive particle detectors would be applicable to rare-event searches such as the direct detection of dark matter, neutrinoless double-beta decay, or coherent neutrino-nucleus scattering

    Getting the elastic scattering length by observing inelastic collisions in ultracold metastable helium atoms

    Full text link
    We report an experiment measuring simultaneously the temperatureand the flux of ions produced by a cloud of triplet metastablehelium atoms at the Bose-Einstein critical temperature. The onsetof condensation is revealed by a sharp increase of the ion fluxduring evaporative cooling. Combining our measurements withprevious measurements of ionization in a pure BEC,we extract an improved value of the scattering lengtha=11.31+2a=11.3^{+2}_{-1} nm. The analysis includes corrections takinginto accountthe effect of atomic interactions on the criticaltemperature, and thus an independent measurement of the scatteringlength would allow a new test of these calculations

    Strongly quadrature-dependent noise in superconducting micro-resonators measured at the vacuum-noise limit

    Full text link
    We measure frequency- and dissipation-quadrature noise in superconducting lithographed microwave resonators with sensitivity near the vacuum noise level using a Josephson parametric amplifier. At an excitation power of 100~nW, these resonators show significant frequency noise caused by two-level systems. No excess dissipation-quadrature noise (above the vacuum noise) is observed to our measurement sensitivity. These measurements demonstrate that the excess dissipation-quadrature noise is negligible compared to vacuum fluctuations, at typical readout powers used in micro-resonator applications. Our results have important implications for resonant readout of various devices such as detectors, qubits and nano-mechanical oscillators.Comment: 13 pages, 4 figure

    A titanium-nitride near-infrared kinetic inductance photon-counting detector and its anomalous electrodynamics

    Get PDF
    We demonstrate single-photon counting at 1550 nm with titanium-nitride (TiN) microwave kinetic inductance detectors. Energy resolution of 0.4 eV and arrival-time resolution of 1.2 microseconds are achieved. 0-, 1-, 2-photon events are resolved and shown to follow Poisson statistics. We find that the temperature-dependent frequency shift deviates from the Mattis-Bardeen theory, and the dissipation response shows a shorter decay time than the frequency response at low temperatures. We suggest that the observed anomalous electrodynamics may be related to quasiparticle traps or subgap states in the disordered TiN films. Finally, the electron density-of-states is derived from the pulse response.Comment: 4 pages, 3 figure

    Family physician involvement in cancer care follow-up: the experience of a cohort of patients with lung cancer.

    Get PDF
    PURPOSE There has been little research describing the involvement of family physicians in the follow up of patients with cancer especially during the primary treatment phase We undertook a prospective longitudinal study of patients with lung cancer to assess their family physician s involvement in their follow up at the different phases of cancer METHODS In 5 hospitals in the province of Quebec Canada patients with a recent diagnosis of lung cancer were surveyed every 3 to 6 months whether they had metastasis or not, for a maximum of 18 months to assess aspects of their family physician s involvement in cancer care RESULTS Of the 395 participating patients 92% had a regular family physician but only 60% had been referred to a specialist by him/her or a colleague for the diagnosis of their lung cancer A majority of patients identified the oncology team or oncologists as mainly responsible for their cancer care throughout their cancer journey except at the advanced phase where a majority attributed this role to their family physician At baseline only 16% of patients perceived a shared care pattern between their family physician and oncologists but this pro portion increased with cancer progression Most patients would have liked their family physician to be more involved in all aspects of cancer care CONCLUSIONS Although patients perceive that the oncology team is the main party responsible for the follow up of their lung cancer they also wish their family physicians to be involved Better communication and collaboration between family physicians and the oncology team are needed to facilitate shared care in cancer follow u

    Horn-Coupled, Commercially-Fabricated Aluminum Lumped-Element Kinetic Inductance Detectors for Millimeter Wavelengths

    Get PDF
    We discuss the design, fabrication, and testing of prototype horn-coupled, lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic microwave background (CMB) studies. The LEKIDs are made from a thin aluminum film deposited on a silicon wafer and patterned using standard photolithographic techniques at STAR Cryoelectronics, a commercial device foundry. We fabricated twenty-element arrays, optimized for a spectral band centered on 150 GHz, to test the sensitivity and yield of the devices as well as the multiplexing scheme. We characterized the detectors in two configurations. First, the detectors were tested in a dark environment with the horn apertures covered, and second, the horn apertures were pointed towards a beam-filling cryogenic blackbody load. These tests show that the multiplexing scheme is robust and scalable, the yield across multiple LEKID arrays is 91%, and the noise-equivalent temperatures (NET) for a 4 K optical load are in the range 26\thinspace\pm6 \thinspace \mu \mbox{K} \sqrt{\mbox{s}}

    A Titanium Nitride Absorber for Controlling Optical Crosstalk in Horn-Coupled Aluminum LEKID Arrays for Millimeter Wavelengths

    Full text link
    We discuss the design and measured performance of a titanium nitride (TiN) mesh absorber we are developing for controlling optical crosstalk in horn-coupled lumped-element kinetic inductance detector arrays for millimeter-wavelengths. This absorber was added to the fused silica anti-reflection coating attached to previously-characterized, 20-element prototype arrays of LEKIDs fabricated from thin-film aluminum on silicon substrates. To test the TiN crosstalk absorber, we compared the measured response and noise properties of LEKID arrays with and without the TiN mesh. For this test, the LEKIDs were illuminated with an adjustable, incoherent electronic millimeter-wave source. Our measurements show that the optical crosstalk in the LEKID array with the TiN absorber is reduced by 66\% on average, so the approach is effective and a viable candidate for future kilo-pixel arrays.Comment: 7 pages, 5 figures, accepted for publication in the Journal of Low Temperature Physic

    High-resolution gamma-ray detection using phonon-mediated detectors

    Get PDF
    We are presenting the results of our ongoing efforts to develop a new type of focal plane detector for the 10 to 100 keV band with an energy resolution of 0.1 %. The device will measure energy and position by using microwave kinetic inductance detectors (MKIDs) to sense athermal phonons created by photon absorption in a dielectric substrate. We have fabricated a proof-of-concept detector of size 2 cm × 2 cm × 1 mm on silicon, which has demonstrated a baseline energy resolution of = 0.38 keV and = 0.55 keV at 30 keV
    corecore