2,165 research outputs found
Handling and analysis of ices in cryostats and glove boxes in view of cometary samples
Comet nucleus sample return mission and other return missions from planets and satellites need equipment for handling and analysis of icy samples at low temperatures under vacuum or protective gas. Two methods are reported which were developed for analysis of small icy samples and which are modified for larger samples in cometary matter simulation experiments (KOSI). A conventional optical cryostat system was modified to allow for transport of samples at 5 K, ion beam irradiation, and measurement in an off-line optical spectrophotometer. The new system consists of a removable window plug containing nozzles for condensation of water and volatiles onto a cold finger. This plug can be removed in a vacuum system, changed against another plug (e.g., with other windows (IR, VIS, VUV) or other nozzles). While open, the samples can be treated under vacuum with cooling by manipulators (cut, removal, sample taking, irradiation with light, photons, or ions). After bringing the plug back, the samples can be moved to another site of analysis. For handling the 30 cm diameter mineral-ice samples from the KOSI experiments an 80x80x80 cm glove box made out of plexiglass was used. The samples were kept in a liquid nitrogen bath, which was filled from the outside. A stream a dry N2 and evaporating gas from the bath purified the glove box from impurity gases and, in particular, H2O, which otherwise would condense onto the samples
Composition and luminescence studies of InGaN epilayers grown at different hydrogen flow rates
Indium gallium nitride (In(x)Ga(1-x)N) is a technologically important material for many optoelectronic devices, including LEDs and solar cells, but it remains a challenge to incorporate high levels of InN into the alloy while maintaining sample quality. A series of InGaN epilayers was grown with different hydrogen flow rates (0-200 sccm) and growth temperatures (680-750 °C) to obtain various InN fractions and bright emission in the range 390-480 nm. These 160-nm thick epilayers were characterized through several compositional techniques (wavelength dispersive x-ray spectroscopy, x-ray diffraction, Rutherford backscattering spectrometry) and cathodoluminescence hyperspectral imaging. The compositional analysis with the different techniques shows good agreement when taking into account compositional gradients evidenced in these layers. The addition of small amounts of hydrogen to the gas flow at lower growth temperatures is shown to maintain a high surface quality and luminescence homogeneity. This allowed InN fractions of up to ~16% to be incorporated with minimal peak energy variations over a mapped area while keeping a high material quality
MALDI Imaging Mass Spectrometry (MALDI-IMS)—Application of Spatial Proteomics for Ovarian Cancer Classification and Diagnosis
MALDI imaging mass spectrometry (MALDI-IMS) allows acquisition of mass data for metabolites, lipids, peptides and proteins directly from tissue sections. IMS is typically performed either as a multiple spot profiling experiment to generate tissue specific mass profiles, or a high resolution imaging experiment where relative spatial abundance for potentially hundreds of analytes across virtually any tissue section can be measured. Crucially, imaging can be achieved without prior knowledge of tissue composition and without the use of antibodies. In effect MALDI-IMS allows generation of molecular data which complement and expand upon the information provided by histology including immuno-histochemistry, making its application valuable to both cancer biomarker research and diagnostics. The current state of MALDI-IMS, key biological applications to ovarian cancer research and practical considerations for analysis of peptides and proteins on ovarian tissue are presented in this review
Recommended from our members
Principles for developing benchmark criteria for staff training in responsible gambling
One approach to minimizing the negative consequences of excessive gambling is staff training to reduce the rate of the development of new cases of harm or disorder within their customers. The primary goal of the present study was to assess suitable benchmark criteria for the training of gambling employees at casinos and lottery retailers. The study utilised the Delphi Method, a survey with one qualitative and two quantitative phases. A total of 21 invited international experts in the responsible gambling field participated in all three phases. A total of 75 performance indicators were outlined and assigned to six categories: (1) criteria of content, (2) modelling, (3) qualification of trainer, (4) framework conditions, (5) sustainability and (6) statistical indicators. Nine of the 75 indicators were rated as very important by 90 % or more of the experts. Unanimous support for importance was given to indicators such as (1) comprehensibility and (2) concrete action-guidance for handling with problem gamblers, Additionally, the study examined the implementation of benchmarking, when it should be conducted, and who should be responsible. Results indicated that benchmarking should be conducted every 1–2 years regularly and that one institution should be clearly defined and primarily responsible for benchmarking. The results of the present study provide the basis for developing a benchmarking for staff training in responsible gambling
The vascular bone marrow niche influences outcome in chronic myeloid leukemia via the E-selectin - SCL/TAL1-CD44 axis.
The endosteal bone marrow niche and vascular endothelial cells provide sanctuaries for leukemic cells. In murine chronic myeloid leukemia (CML) CD44 on leukemia cells and E-selectin on bone marrow endothelium are essential mediators for the engraftment of leukemic stem cells. We hypothesized that non-adhesion of CML-initiating cells to E-selectin on the bone marrow endothelium may lead to superior eradication of leukemic stem cells in CML after treatment with imatinib than imatinib alone. Indeed, here we show that treatment with the E-selectin inhibitor GMI-1271 in combination with imatinib prolongs survival of mice with CML via decreased contact time of leukemia cells with bone marrow endothelium. Non-adhesion of BCR-ABL1(+) cells leads to an increase of cell cycle progression and an increase of expression of the hematopoietic transcription factor and proto-oncogene Scl/Tal1 in leukemia-initiating cells. We implicate SCL/TAL1 as an indirect phosphorylation target of BCR-ABL1 and as a negative transcriptional regulator of CD44 expression. We show that increased SCL/TAL1 expression is associated with improved outcome in human CML. These data demonstrate the BCR-ABL1-specific, cell-intrinsic pathways leading to altered interactions with the vascular niche via the modulation of adhesion molecules - which could be exploited therapeutically in the future
High-throughput and high-precision laser micromachining with ps-pulses in synchronized mode with a fast polygon line scanner
To be competitive in laser micro machining, high throughput is an important aspect. One possibility to increase productivity is scaling up the ablation process i.e. linearly increasing the laser repetition rate together with the average power and the scan speed. In the MHz-regime high scan speeds are required which cannot be provided by commercially available galvo scanners. In this work we will report on the results by using a polygon line scanner having a maximum scan speed of 100 m/s and a 50 W ps-laser system, synchronized via the SuperSync™ technology. We will show the results concerning the removal rate and the surface quality for working at the optimum point i.e. most efficient point at repetition rates up to 8.2 MHz
Observations of Rabi oscillations in a non-polar InGaN quantum dot
Experimental observation of Rabi rotations between an exciton excited state and the crystal ground state in a single non-polar InGaN quantum dot is presented. The exciton excited state energy is determined by photoluminescence excitation spectroscopy using two-photon excitation from a pulsed laser. The population of the exciton excited state is seen to undergo power dependent damped Rabi oscillations.This research was supported by the Engineering and Physical Sciences Research Council (EPSRC) U.K. (Grant No. EP/H047816/1).This version is the author accepted manuscript. The published version can also be found on the publisher's website at: http://scitation.aip.org/content/aip/journal/apl/104/26/10.1063/1.4886961 © 2014 AIP Publishing LL
- …