Validation, reproducibility and safety of trans dermal electrical stimulation in chronic pain patients and healthy volunteers
<p>Abstract</p> <p>Background</p> <p>Surrogate pain models have been extensively tested in Normal Human Volunteers (NHV). There are few studies that examined pain models in chronic pain patients. Patients are likely to have altered pain mechanisms. It is of interest to test patient pain responses to selective pain stimuli under controlled laboratory conditions.</p> <p>Methods</p> <p>The Institutional Ethic Committee approved the study. 16 patients with chronic neuropathic radiculopathy and 16 healthy volunteers were enrolled to the study after obtaining informed consent. During electrical stimulation (150 minutes for volunteers and 75 minutes for patients) the following parameters were measured every 10 minutes:</p> <p>Ongoing pain: Visual Analogue Scale (VAS) and Numeric Rate Scale (NRS)</p> <p>Allodynia (soft foam brush)</p> <p>Hyperalgesia (von Frey monofilament 20 g)</p> <p>Flare</p> <p>For each endpoint, the area under the curve (AUC) was estimated from the start of stimulation to the end of stimulation by the trapezoidal rule. The individual AUC values for both periods were plotted to show the inter- and intra-subject variability. For each endpoint a mixed effect model was fitted with random effect subject and fixed effect visit. The estimate of intra-subject variance and the mean value were then used to estimate the sample size of a crossover study required to have a probability of 0.80 to detect a 25% change in the mean value. Analysis was done using GenStat 8<sup>th </sup>edition.</p> <p>Results</p> <p>Each endpoint achieved very good reproducibility for patients and NHV. Comparison between groups revealed trends towards:</p> <p>Faster habituation to painful stimuli in patients</p> <p>Bigger areas of hyperalgesia in patients</p> <p>Similar area of allodynia and flare (no statistical significance)</p> <p>Conclusion</p> <p>The differences demonstrated between patients and NHVs suggest that the electrical stimulation device used here may stimulate pathways that are affected in the pathological state.</p
Systematic review of targeted axillary dissection in node-positive breast cancer treated with neoadjuvant systemic therapy:variation in type of marker and timing of placement
Background: In node-positive (cN+) breast cancer treated with neoadjuvant systemic therapy, combining sentinel lymph node biopsy and targeted lymph node excision, that is targeted axillary dissection, increases accuracy. Targeted axillary dissection procedures differ in terms of the targeted lymph node excision technique. This systematic review aimed to provide an overview of targeted axillary dissection procedures regarding definitive marker type and timing of placement: before neoadjuvant systemic therapy (1-step procedure) or after neoadjuvant systemic therapy adjacent to a clip placed before the neoadjuvant therapy (2-step procedure). Methods: PubMed and Embase were searched, to 4 July 2023, for RCTs, cohort studies, and case-control studies with at least 25 patients. Studies of targeted lymph node excision only (without sentinel lymph node biopsy), or where intraoperative localization of the targeted lymph node was not attempted, were excluded. For qualitative synthesis, studies were grouped by definitive marker and timing of placement. The targeted lymph node identification rate was reported. Study quality was assessed using a National Institutes of Health quality assessment tool.Results: Of 277 unique records, 51 studies with a total of 4512 patients were included. Six definitive markers were identified: wire, 125I-labelled seed, 99mTc, (electro)magnetic/radiofrequency markers, black ink, and a clip. Fifteen studies evaluated one-step procedures, with the identification rate of the targeted lymph node at surgery varying from 8 of 13 to 47 of 47. Forty-one studies evaluated two-step procedures, with the identification rate of the clipped targeted lymph node on imaging after neoadjuvant systemic therapy varying from 49 to 100%, and the identification rate of the targeted lymph node at surgery from 17 of 24 to 100%. Most studies (40 of 51) were rated as being of fair quality.Conclusion: Various targeted axillary dissection procedures are used in clinical practice. Owing to study heterogeneity, the optimal targeted lymph node excision technique in terms of identification rate and feasibility could not be determined. Two-step procedures are at risk of not identifying the clipped targeted lymph node on imaging after neoadjuvant systemic therapy.</p
Demographics and Functional Outcome of Toe Fractures
Toe fractures are common; however, there are few data on demographics and functional outcome. We studied outcomes in 339 consecutive patients with toe fractures treated between January 2006 and September 2008. Two hundred and sixty-four patients, aged 16 to 75, were mailed an outcome questionnaire, and overall subjective satisfaction with the outcome of treatment was measured using a visual analog scale (VAS). Most frequently affected were the first (38%) and fifth (30%) toes, and most (75.6%) of the fractures were caused by stubbing or crush injury. More than 95% of the fractures were displaced less than 2 mm, and all of the fractures were treated conservatively. The questionnaire was returned by 141 (53%) patients with a median follow-up of 27 months. Respondents were female in 57.4% of cases and had a median age of 45 years. The median AOFAS score was 100 (P25, P75= 93,100) points; the median VAS was 10 (P25, P75= 8, 10) points. Univariate regression analysis revealed no statistically significant associations between outcome and the particular toe or phalanx involved, number of fractured toes, fracture type and location, articular involvement, gender, age, body mass index, smoking habits, and the presence of diabetes mellitus. Satisfaction VAS was dependent on age (P = .047) and gender (P = .049) in the multivariate analysis. The AOFAS midfoot score was not influenced by any of the covariates. This is the first epidemiological investigation using 2 outcome-scoring systems to determine function and satisfaction following treatment of toe fractures
The performance of GridPix detectors
A GridPix detector is a gaseous detector capable of detecting individual single primary electrons from ionizing particles. Such a detector consists of a pixel chip as active anode covered with a thin layer of silicon rich silicon nitride (SiRN) for protection against discharges, an integrated amplification grid (InGrid), applied on top of the chip by wafer post processing techniques, and a cathode plane. The drift region is between the grid and cathode while the gas gain occurs between the chip and the grid. The discharge quenching properties of the SiRN layer have been determined as well as the relation on grid capacitance, grid voltage and gas mixture. Part of the detectors in this report were of the type Gossip, a GridPix detector with a drift gap of ∼1 mm. Using such thin drift layer, one may consider this detector as a replacement for a silicon pixel detector. The performance of three Gossip detectors has been investigated by measurements in a test beam at CERN
The association between birth weight and plasma fibrinogen is abolished after the elimination of genetic influences
Low birth weight is associated with an increased risk of atherothrombosis, which may be related in part to the association between low birth weight and high plasma fibrinogen. The association between birth weight and fibrinogen may be explained by intrauterine, socio-economic or genetic factors. We examined birth weight and fibrinogen in 52 dizygotic and 56 adolescent monozygotic (genetically identical) twin pairs. The dizygotic but not the monozygotic twins with the lowest birth weight from each pair had a fibrinogen level that was higher compared with their co-twins with the highest birth weight [dizygotic twins: 2.62±0.46 g
Hyperbaric oxygen therapy for late radiation-induced tissue toxicity: Prospectively patient-reported outcome measures in breast cancer patients
__Introduction:__ This study examines patient reported outcome measures of women undergoing hyperbaric oxygen treatment (HBOT) after breast-conserving therapy.
__Method:__ Included were 57 women treated with HBOT for late radiation-induced tissue toxicity (LRITT) referred in the period January 2014-December 2015. HBOT consisted of (on average) 47 sessions. In total, 80 min of 100 % O2 was administered under increased pressure of 2.4 ATA. Quality of life was assessed before and after treatment using the European Organization for Research and Treatment of Cancer (EORTC) QLQ-BR23, and a NRS pain score.
__Results:__ Fifty-seven women were available for evaluation before and after treatment. Before HBOT, patients had severe complaints of pain in the arm/shoulder (46 %), swollen arm/hand (14 %), difficulty to raise arm or move it sideways (45 %), pain in the area of the affected breast (67 %), swollen area of the affected breast (45 %), oversensitivity of the affected breast (54 %), and skin problems on/in the area of the affected breast (32 %); post HBOT, severe complaints were still experienced in 17, 7, 22, 15, 13, 15, and 11 % of the women, respectively. Differences were all significant. The NRS pain score improved at least 1 point (range 0-10) in 81 % of the patients (p < 0.05).
__Conclusion:__ In these breast cancer patients treated with HBOT for LRITT, the patient-reported outcomes were positive and improvements were observed. HBOT was a well-tolerated treatment for LRITT and its side-effects were both minimal and reversible
MicroRNA expression in pre-treatment plasma of patients with benign breast diseases and breast cancer
__Background:__ MicroRNAs (miRs) are small RNA molecules, influencing messenger RNA (mRNA) expression and t
BRCA2 polymorphic stop codon K3326X and the risk of breast, prostate, and ovarian cancers
Background: The K3326X variant in BRCA2 (BRCA2*c.9976A>T; p.Lys3326*; rs11571833) has been found to be associated with small increased risks of breast cancer. However, it is not clear to what extent linkage disequilibrium with fully pathogenic mutations might account for this association. There is scant information about the effect of K3326X in other hormone-related cancers.
Methods: Using weighted logistic regression, we analyzed data from the large iCOGS study including 76 637 cancer case patients and 83 796 control patients to estimate odds ratios (ORw) and 95% confidence intervals (CIs) for K3326X variant carriers in relation to breast, ovarian, and prostate cancer risks, with weights defined as probability of not having a pathogenic BRCA2 variant. Using Cox proportional hazards modeling, we also examined the associations of K3326X with breast and ovarian cancer risks among 7183 BRCA1 variant carriers. All statistical tests were two-sided.
Results: The K3326X variant was associated with breast (ORw = 1.28, 95% CI = 1.17 to 1.40, P = 5.9x10- 6) and invasive ovarian cancer (ORw = 1.26, 95% CI = 1.10 to 1.43, P = 3.8x10-3). These associations were stronger for serous ovarian cancer and for estrogen receptor–negative breast cancer (ORw = 1.46, 95% CI = 1.2 to 1.70, P = 3.4x10-5 and ORw = 1.50, 95% CI = 1.28 to 1.76, P = 4.1x10-5, respectively). For BRCA1 mutation carriers, there was a statistically significant inverse association of the K3326X variant with risk of ovarian cancer (HR = 0.43, 95% CI = 0.22 to 0.84, P = .013) but no association with breast cancer. No association with prostate cancer was observed.
Conclusions: Our study provides evidence that the K3326X variant is associated with risk of developing breast and ovarian cancers independent of other pathogenic variants in BRCA2. Further studies are needed to determine the biological mechanism of action responsible for these associations
- …