86 research outputs found

    Economic Investigation of Community-Scale Versus Building Scale Net-Zero Energy

    Full text link
    The study presented in this report examines issues concerning whether achieving net-zero energy performance at the community scale provides economic and potentially overall efficiency advantages over strategies focused on individual buildings

    Enhancing Building Operations Through Automated Diagnostics: Field Test Results

    Get PDF
    The Whole Building Diagnostician (WBD) is a modular diagnostic software system that provides detection and diagnosis of problems with the operation of heating, ventilation, and air-conditioning (HVAC) systems and major energy end-uses. It has been extensively field tested and demonstrated in buildings over the past several years. WBD found problems with many air-handling units at all sites. The problems ranged from a simple set point deviation to improper implementation of controls. The results from these demonstrations, along with the feedback from building operators and managers on the use of diagnostic tools, are presented in the paper. Experience from field tests indicates that providing diagnostic tools to building operators can increase their awareness of equipment faults, but it will not by itself solve the problems of inefficient operations. Changes in operation and maintenance practices and behavior are needed. We discuss how these new technologies might be delivered and used more effectively to better manage facilities, improving their condition and increasing their energy efficiency

    Pemetrexed, Carboplatin, and Concomitant Radiation followed by Surgery for Locally Advanced Esophageal Cancer: Results of a Planned Interim Toxicity Analysis of North Central Cancer Treatment Group Study N044E

    Get PDF
    Purpose This brief report describes a planned, interim, 6-patient toxicity analysis that confirms the safety of pemetrexed, carboplatin, radiation with subsequent surgery, as prescribed in the North Central Cancer Treatment Group trial N044E, in patients with locally advanced esophageal cancer. Methods Six patients with locally advanced, potentially resectable esophageal cancer received pemetrexed 500 mg/m 2 and carboplatin AUC = 6 on days 1 and 22 with 5040 centigray of concomitant radiation in 28 fractions over 5.5 weeks followed by esophagectomy as a prelude to a phase II multi-institutional trial. Results Only 1 of the 6 patients experienced a grade 4 adverse event (neutropenia). This patient also experienced a grade 3 depression. Of the remaining 5 patients, three experienced at least one grade 3 adverse event (neutropenia, nausea/vomiting, and esophagitis). There were no deaths. Incidentally, one patient manifested a complete pathologic response, three a partial pathologic response, and one stable disease. Conclusion These preliminary observations on safety suggest that this regimen can be further studied in this clinical setting

    Energy Savings and Economics of Advanced Control Strategies for Packaged Air-Conditioning Units with Gas Heat

    Full text link
    Pacific Northwest National Laboratory (PNNL) with funding from the U.S. Department of Energy's Building Technologies Program (BTP) evaluated a number of control strategies that can be implemented in a controller, to improve the operational efficiency of the packaged air conditioning units. The two primary objectives of this research project are: (1) determine the magnitude of energy savings achievable by retrofitting existing packaged air conditioning units with advanced control strategies not ordinarily used for packaged units and (2) estimating what the installed cost of a replacement control with the desired features should be in various regions of the U.S. This document reports results of the study

    Demonstration of the Whole-Building Diagnostician in a Single-Building Operator Environment

    Get PDF
    This report on documents the results of the single-building-operator, on-line, demonstration of the Whole-Building Diagnostician, conducted at the Symphony Towers building in San Diego, California. The on-line test was designed to evaluate the Outdoor-Air Economizer (OAE) diagnostic module’s capabilities to automatically and continually diagnose operational problems with air-handling units (AHUs). As part of this demonstration, all four AHUs at Symphony Towers were monitored. The measured data that were collected on a continuous basis included: 1) outdoor-air temperature, 2) return-air temperature, 3) mixed-air temperature, 4) supply-air temperature, 5) chilled-water valve position, 6) supply-fan status, 7) outdoor-air relative humidity, and 8) return-air relative humidity
    corecore