88 research outputs found

    Combined percutaneous coronary atherectomy and coronary angioplasty: Experience in 19 consecutive patients

    Get PDF
    AbstractAmong 82 patients undergoing coronary atherectomy, 19 (23%) underwent this procedure in combination with coronary angioplasty. The most frequently involved vessel was the left anterior descending coronary artery. In 11 patients (58%), attempted atherectomy preceded coronary angioplasty. In 6 of the 11, angioplasty was used after the atherectomy catheter could not be positioned across the lesion; 4 patients underwent “rescue” angioplasty after developing vessel occlusion related to atherectomy and 1 patient had an unsatisfactory result of atherectomy. The success rate of the combined intervention was 82% for these 11 patients.In eight patients (42%), atherectomy was performed after initial angioplasty. In four of the eight, atherectomy was a rescue procedure to manage vessel occlusion by thrombus or intimal dissection and was successful in three. In the other four, angioplasty was performed to establish an easier passage for the atherectomy catheter and was successful in three. Thus, the success rate of the combined intervention was 75% for these eight patients.The overall success rate for all 19 patients was 79%; there was one in-hospital death and one non-Q wave infarction, and one patient required immediate coronary artery surgery. Two other patients underwent coronary artery surgery before hospital discharge. Combined intervention with coronary angioplasty and atherectomy seems to be a relatively safe and effective approach in selected patients when either of these procedures alone is unsuccessful or is accompanied by acute coronary complications

    Changing experience with dual chamber (DDD) pacemakers

    Get PDF
    Dual chamber (DDD) or “universal” pacemakers have had a significant impact on the advancement of artificial pacemakers by providing a more physiologic approach to cardiac pacing. However, with the early generation of DDD pacemakers (pacemakers that sense and pace in both the atrium and the ventricle), a significant number of patients experienced pacemaker-mediated tachycardia because intact ventriculoatrial conduction was sensed in the atrium and a reentrant tachycardia was induced. Newer generation DDD pacemakers have provided longer atrial refractory periods, which should correct this problem.In this study the first and second years of a 2 year experience with DDD pacemakers were compared to determine if the newer generation devices have allowed maintenance of pacing in the DDD mode as opposed to reprogramming to some alternate mode because of pacemaker-mediated tachycardia or other pacing problems. The results showed a significant decrease in pacemaker-mediated tachycardia during the second year and continuation of pacing in the DDD mode in a higher percent of patients. This improvement is attributed to improvement in the pulse generator as well as better patient selection

    Restenosis after directional coronary atherectomy: Differences between primary atheromatoes and restenosls lesions and influence of subintimal tissue resection

    Get PDF
    AbstractRates of restenosis were evaluated in 70 patients (74 lesions) after successful directional coronary atherectomy. The extent of vascular tissue resection was correlated with restenosis rates for coronary (n = 59) and vein bypass graft (n = 15) lesions.After 6 months, the overall restenosis rate was 50% (37 of 74 lesions); it was 42% (15 of 36 lesions) when intima alone was resected, 50% (7 of 14 lesions) when media was resected and 63% (15 of 24 lesions) when adventitia was resected. Subintimal tissue resection increased the restenosis rate for vein grafts (43% with intimal resection versus 100% with subintimal resection, p = 0.01) but not for coronary arteries (50% versus 48%). There was no overall difference in restenosis rates after atherectomy between primary lesions and restenosis lesions that occurred after balloon angioplasty (46% versus 54%). Among postballoon angioplasty restenosis lesions, a higher rate of restenosis after atherectomy was found with subintimal than with intimal resection (78% versus 32%, p = 0.01).Tissues from patients undergoing a second atherectomy for restenosis after initial atherectomy (n = 8) demonstrated neointimal hyperplasia that appeared histotogically identical to restenotic tissue developing after balloon angioplasty (n = 37).These data suggest that the cellular response to directional coronary atherectomy is characterized by neointimal proliferation similar to that which may develop after balloon angioplasty. The extent of fibrous hyperplasia appears to be related to the depth of tissue resection in vein graft lesions and coronary artery restenosis lesions that occur after balloon angioplasty but not in primary atheromatous coronary artery lesions

    Effect of external beam irradiation on neointimal hyperplasia after experimental coronary artery injury

    Get PDF
    AbstractHuman coronary artery restenosis after percutaneous revascularization is a response to mechanical injury. Smooth muscle cell proliferation is a major component of restenosis, resulting in obstructive neointimal hyperplasia. Because ionizing radiation inhibits cellular proliferation, this study tested in a porcine coronary injury model the hypothesis that the hyperplastic response to coronary artery injury would be attenuated by X-irradiation.Deep arterial injury was produced in 37 porcine left anterior descending coronary artery segments with overexpanded, percutaneously delivered tantalum wire coils. Three groups of pigs were irradiated with 300-kV X-rays after coil injury: Group I (n = 10), 400 cGy at 1 day; Group II (n = 10), 400 cGy at 1 day and 400 cGy at 4 days and Group III (n = 9), 800 cGy at 1 day. Eight pigs in the control group underwent identical injury but received no radiation. Treatment efficacy was histologically assessed by measuring neointimal thickness and percent area stenosis.Mean neointimal thickness in all irradiated groups was significantly higher than in the control groups and thickness was proportional to X-ray dose.X-irradiation delivered at these doses and times did not inhibit proliferative neointima. Rather, it accentuated the neointimal response to acute arterial injury and may have potentiated that injury

    Automated extraction of potential migraine biomarkers using a semantic graph

    Get PDF
    Problem Biomedical literature and databases contain important clues for the identification of potential disease biomarkers. However, searching these enormous knowledge reservoirs and integrating findings across heterogeneous sources is costly and difficult. Here we demonstrate how semantically integrated knowledge, extracted from biomedical literature and structured databases, can be used to automatically identify potential migraine biomarkers. Method We used a knowledge graph containing more than 3.5 million biomedical concepts and 68.4 million relationships. Biochemical compound concepts were filtered and ranked by their potential as biomarkers based on their connections to a subgraph of migraine-related concepts. The ranked results were evaluated against the results of a systematic literature review that was performed manually by migraine researchers. Weight points were assigned to these reference compounds to indicate their relative importance. Results Ranked results automatically generated by the knowledge graph were highly consistent with results from the manual literature review. Out of 222 reference compounds, 163 (73%) ranked in the top 2000, with 547 out of the 644 (85%) weight points assigned to the reference compounds. For reference compounds that were not in the top of the list, an extensive error analysis has been performed. When evaluating the overall performance, we obtained a ROC-AUC of 0.974. Discussion Semantic knowledge graphs composed of information integrated from multiple and varying sources can assist researchers in identifying potential disease biomarkers

    The Radiation Issue in Cardiology: the time for action is now

    Get PDF
    The "radiation issue" is the need to consider possible deterministic effects (e.g., skin injuries) and long-term cancer risks due to ionizing radiation in the risk-benefit assessment of diagnostic or therapeutic testing. Although there are currently no data showing that high-dose medical studies have actually increased the incidence of cancer, the "linear-no threshold" model in radioprotection assumes that no safe dose exists; all doses add up in determining cancer risks; and the risk increases linearly with increasing radiation dose. The possibility of deterministic effects should also be considered when skin or lens doses may be over the threshold. Cardiologists have a special mission to avoid unjustified or non-optimized use of radiation, since they are responsible for 45% of the entire cumulative effective dose of 3.0 mSv (similar to the radiological risk of 150 chest x-rays) per head per year to the US population from all medical sources except radiotherapy. In addition, interventional cardiologists have an exposure per head per year two to three times higher than that of radiologists. The most active and experienced interventional cardiologists in high volume cath labs have an annual exposure equivalent to around 5 mSv per head and a professional lifetime attributable to excess cancer risk on the order of magnitude of 1 in 100. Cardiologists are the contemporary radiologists but sometimes imperfectly aware of the radiological dose of the examination they prescribe or practice, which can range from the equivalent of 1-60 mSv around a reference dose average of 10-15 mSv for a percutaneous coronary intervention, a cardiac radiofrequency ablation, a multi-detector coronary angiography, or a myocardial perfusion imaging scintigraphy. A good cardiologist cannot be afraid of life-saving radiation, but must be afraid of radiation unawareness and negligence

    Annual and seasonal movements of migrating short-tailed shearwaters reflect environmental variation in sub-Arctic and Arctic waters

    Get PDF
    The marine ecosystems of the Bering Sea and adjacent southern Chukchi Sea are experiencing rapid changes due to recent reductions in sea ice. Short-tailed shearwaters Puffinus tenuirostris visit this region in huge numbers between the boreal summer and autumn during non-breeding season, and represent one of the dominant top predators. To understand the implications for this species of ongoing environmental change in the Pacific sub-Arctic and Arctic seas, we tracked the migratory movements of 19 and 24 birds in 2010 and 2011, respectively, using light-level geolocators. In both years, tracked birds occupied the western (Okhotsk Sea and Kuril Islands) and eastern (southeast Bering Sea) North Pacific from May to July. In August–September of 2010, but not 2011, a substantial proportion (68 % of the tracked individuals in 2010 compared to 38 % in 2011) moved through the Bering Strait to feed in the Chukchi Sea. Based on the correlation with oceanographic variables, the probability of shearwater occurrence was highest in waters with sea surface temperatures (SSTs) of 8–10 °C over shallow depths. Furthermore, shearwaters spent more time flying when SST was warmer than 9 °C, suggesting increased search effort for prey. We hypothesized that the northward shift in the distribution of shearwaters may have been related to temperature-driven changes in the abundance of their dominant prey, krill (Euphausiacea), as the timing of krill spawning coincides with the seasonal increase in water temperature. Our results indicate a flexible response of foraging birds to ongoing changes in the sub-Arctic and Arctic ecosystems

    A Brief History of Marine Litter Research

    Full text link
    • …
    corecore