112 research outputs found

    Low-voltage nanodomain writing in He-implanted lithium niobate crystals

    Full text link
    A scanning force microscope tip is used to write ferroelectric domains in He-implanted single-crystal lithium niobate and subsequently probe them by piezoresponse force microscopy. Investigation of cross-sections of the samples showed that the buried implanted layer, 1\sim 1\,\textmu m below the surface, is non-ferroelectric and can thus act as a barrier to domain growth. This barrier enabled stable surface domains of <1< 1\,\textmu m size to be written in 500\,\textmu m-thick crystal substrates with voltage pulses of only 10\,V applied to the tip

    Novel method for non‐traumatic creation of a colostomy

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/93530/1/ans6160.pd

    Novel method for non‐traumatic creation of a colostomy

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/93530/1/ans6160.pd

    Lead-related quantum emitters in diamond

    Get PDF
    We report on quantum emission from Pb-related color centers in diamond following ion implantation and high-temperature vacuum annealing. First-principles calculations predict a negatively charged Pb-vacancy (PbV) center in a split-vacancy configuration, with a zero-phonon transition around 2.4 eV. Cryogenic photoluminescence measurements performed on emitters in nanofabricated pillars reveal several transitions, including a prominent doublet near 520 nm. The splitting of this doublet, 5.7 THz, exceeds that reported for other group-IV centers. These observations are consistent with the PbV center, which is expected to have a combination of narrow optical transitions and stable spin states, making it a promising system for quantum network nodes.U.S. Army Research Laboratory. Center for Distributed Quantum InformationNational Science Foundation (U.S.). Graduate Research Fellowship ProgramNational Science Foundation (U.S.) (Grant DMR-1231319)United States. National Aeronautics and Space Administration (Space Technology Research Fellowship)MIT-Harvard Center for Ultracold Atoms MIT International Science and Technology Initiativ

    Transform-limited photons from a coherent tin-vacancy spin in diamond

    Get PDF
    Solid-state quantum emitters that couple coherent optical transitions to long-lived spin qubits are essential for quantum networks. Here we report on the spin and optical properties of individual tin-vacancy (SnV) centers in diamond nanostructures. Through cryogenic magneto-optical and spin spectroscopy, we verify the inversion-symmetric electronic structure of the SnV, identify spin-conserving and spin-flipping transitions, characterize transition linewidths, measure electron spin lifetimes and evaluate the spin dephasing time. We find that the optical transitions are consistent with the radiative lifetime limit even in nanofabricated structures. The spin lifetime is phononlimited with an exponential temperature scaling leading to T1T_1 >> 10 ms, and the coherence time, T2T_2 reaches the nuclear spin-bath limit upon cooling to 2.9 K. These spin properties exceed those of other inversion-symmetric color centers for which similar values require millikelvin temperatures. With a combination of coherent optical transitions and long spin coherence without dilution refrigeration, the SnV is a promising candidate for feasable and scalable quantum networking applications

    Fully covered self-expanding metal stents placed temporarily in the bile duct: safety profile and histologic classification in a porcine model

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Fully covered Self-Expanding metal stents (FCSEMS) have been shown efficacious in palliating malignant biliary obstructions. There is little data analyzing mucosal response to their temporary placement in the bile duct.</p> <p>Methods</p> <p>Ten mini pigs underwent endoscopic placement of a FCSEMS (Wallflex, Boston Scientific). FCSEMS were kept in place for three months. At the end of the 3 months, FCSEMS were removed endoscopically. Five pigs were euthanized and their bile ducts harvested. The other five were kept alive for another month post removal. A single pathologist, created a scoring system (to determine degree of inflammation, fibrosis, and epithelial injury), examined all specimens in a blinded fashion.</p> <p>Results</p> <p>Four FCSEMS spontaneously migrated in the duodenum. On post mortem examination, mild mucosal thickness was noted in three bile duct specimens while superficial inflammation of the bile duct was noted in five animals. Histologic examination of the bile duct revealed focal acute inflammation in both groups. For the 5 animals euthanized immediately after stent removal, there was a tendency to have superficial mucosal erosion and fibrosis. In contrast, increased chronic inflammation was more commonly seen in the animals 1 month post stent removal, with all animals in this group showing moderate degrees of mononuclear inflammatory cell mucosal infiltrates. No severe inflammatory or fibrotic duct injury was observed in any of the study animals, with degree of injury graded as mild to moderate.</p> <p>Conclusion</p> <p>FCSEMS appear to induce minimal tissue overgrowth or fibrosis post placement. Ease of removability and no significant histologic injury are advantages noted with FCSEMS., however, further studies are needed to evaluate treating benign biliary strictures with FCSEMS in humans.</p

    Adaptive regression modeling of biomarkers of potential harm in a population of U.S. adult cigarette smokers and nonsmokers

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This article describes the data mining analysis of a clinical exposure study of 3585 adult smokers and 1077 nonsmokers. The analysis focused on developing models for four biomarkers of potential harm (BOPH): white blood cell count (WBC), 24 h urine 8-epi-prostaglandin F<sub>2α </sub>(EPI8), 24 h urine 11-dehydro-thromboxane B<sub>2 </sub>(DEH11), and high-density lipoprotein cholesterol (HDL).</p> <p>Methods</p> <p>Random Forest was used for initial variable selection and Multivariate Adaptive Regression Spline was used for developing the final statistical models</p> <p>Results</p> <p>The analysis resulted in the generation of models that predict each of the BOPH as function of selected variables from the smokers and nonsmokers. The statistically significant variables in the models were: platelet count, hemoglobin, C-reactive protein, triglycerides, race and biomarkers of exposure to cigarette smoke for WBC (R-squared = 0.29); creatinine clearance, liver enzymes, weight, vitamin use and biomarkers of exposure for EPI8 (R-squared = 0.41); creatinine clearance, urine creatinine excretion, liver enzymes, use of Non-steroidal antiinflammatory drugs, vitamins and biomarkers of exposure for DEH11 (R-squared = 0.29); and triglycerides, weight, age, sex, alcohol consumption and biomarkers of exposure for HDL (R-squared = 0.39).</p> <p>Conclusions</p> <p>Levels of WBC, EPI8, DEH11 and HDL were statistically associated with biomarkers of exposure to cigarette smoking and demographics and life style factors. All of the predictors togather explain 29%-41% of the variability in the BOPH.</p
    corecore