16 research outputs found

    Compressive properties of commercially available polyurethane foams as mechanical models for osteoporotic human cancellous bone

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Polyurethane (PU) foam is widely used as a model for cancellous bone. The higher density foams are used as standard biomechanical test materials, but none of the low density PU foams are universally accepted as models for osteoporotic (OP) bone. The aim of this study was to determine whether low density PU foam might be suitable for mimicking human OP cancellous bone.</p> <p>Methods</p> <p>Quasi-static compression tests were performed on PU foam cylinders of different lengths (3.9 and 7.7 mm) and of different densities (0.09, 0.16 and 0.32 g.cm<sup>-3</sup>), to determine the Young's modulus, yield strength and energy absorbed to yield.</p> <p>Results</p> <p>Young's modulus values were 0.08–0.93 MPa for the 0.09 g.cm<sup>-3 </sup>foam and from 15.1–151.4 MPa for the 0.16 and 0.32 g.cm<sup>-3 </sup>foam. Yield strength values were 0.01–0.07 MPa for the 0.09 g.cm<sup>-3 </sup>foam and from 0.9–4.5 MPa for the 0.16 and 0.32 g.cm<sup>-3 </sup>foam. The energy absorbed to yield was found to be negligible for all foam cylinders.</p> <p>Conclusion</p> <p>Based on these results, it is concluded that 0.16 g.cm<sup>-3 </sup>PU foam may prove to be suitable as an OP cancellous bone model when fracture stress, but not energy dissipation, is of concern.</p

    Young’s modulus repeatability assessment using cycling compression loading on cancellous bone

    Get PDF
    For various applications, precision of the Young’s modulus of cancellous bone specimens is needed. However, measurement variability is rarely given. The aim of this study was to assess the Young’s modulus repeatability using a uniaxial cyclic compression protocol on embedded specimens of human cancellous bone. Twelve specimens from 12 human calcanei were considered. The specimens were first defatted and then 1 or 2 mm at the ends were embedded in an epoxy resin. The compression experiment consists in applying 20 compressive cycles between 0.2 per cent and 0.6 per cent strain with a 2 Hz loading frequency. The coefficient of variation of the current protocol was found to be 1.2 per cent. This protocol showed variability similar to the end-cap technique (considered as a reference). It can be applied on porous specimen (especially human bone) and requires minimal bone length to limit end-artifact variability. The current method could be applied in association with noninvasive measurements (such as ultrasound) with full compatibility. This possibility opens the way for bone damage follow-up based on Young’s modulus monitoring.Agence Nationale pour la Recherche (ANR), France [Grant BONUS_ 07BLAN0197

    Viability thresholds of ischemic penumbra of hyperacute stroke defined by perfusion-weighted MRI and apparent diffusion coefficient.

    No full text
    International audienceBACKGROUND AND PURPOSE: The penumbra of ischemic stroke consists of hypoperfused, but not irreversibly damaged, tissue surrounding the ischemic core. The purpose of this study was to determine viability thresholds in the ischemic penumbra, defined as the perfusion/diffusion mismatch in hyperacute stroke, by the use of diffusion- and perfusion-weighted MRI (DWI and PWI, respectively). METHODS: DWI and PWI were performed in 11 patients 1.63. Higher sensitivity and accuracy in predicting outcome of the penumbra were obtained from the rCBF maps compared with the rCBV and MTT maps. The initial rCBV and apparent diffusion coefficient ratios did not differentiate between the part of the penumbra that recovered and the part that progressed to infarction. The mean rCBF ratio was optimal in distinguishing the parts of the penumbra recovering or progressing to infarction. CONCLUSIONS: The thresholds found in this study by combined DWI/PWI might aid in the selection of patients suitable for therapeutic intervention within 6 hours. However, these hypothesized thresholds need to be prospectively tested at the voxel level on a larger patient sample before they can be applied clinically

    Correlation between diffusion- and perfusion-weighted MRI and neurological deficit measured by the Scandinavian Stroke Scale and Barthel Index in hyperacute subcortical stroke (< or = 6 hours).

    No full text
    International audienceOBJECTIVE: We used combined diffusion-weighted (DWI) and perfusion-weighted (PWI) MRI to characterize hyperacute infarctions within 6 h of symptom onset with special reference to subcortical infarctions, and investigated the relation between perfusion-diffusion mismatch volume and functional outcome. MATERIAL AND METHODS: Twenty-two patients presenting with symptoms of acute stroke underwent DWI and PWI within 6 h of symptom onset, and follow-up MRI 30 days later. Twelve of these had a subcortical infarction on acute DWI. Lesion volumes were measured by acute DWI and PWI as well as chronic T(2)-weighted MRI (T2WI). Clinical severity was measured by the Scandinavian Stroke Scale (SSS) and the Barthel Index (BI). RESULTS: In the 12 patients with subcortical infarctions, PWI and especially DWI correlated strongly with acute and chronic neurological SSS score, as well as with final infarct volume. Furthermore, a hyperacute PWI/DWI mismatch in this subgroup predicted lesion growth. There was a weaker correlation between acute DWI/PWI and neurological score among all 22 patients, and patients with a PWI/DWI mismatch larger than 100 ml had a significantly larger lesion growth and a poorer outcome than patients with a smaller mismatch. CONCLUSIONS: Subcortical infarctions may represent a sizeable subgroup of acute stroke patients. Also subcortical infarctions may have a PWI/DWI mismatch and therefore may respond to neuroprotective/thrombolytic therapy. Hyperacute DWI may reflect the acute clinical status and predict the outcome in patients with subcortical infarction

    Prediction of tissue survival after middle cerebral artery occlusion based on changes in the apparent diffusion of water.

    No full text
    International audienceOBJECT: In this study the authors tested the hypothesis that the estimate of the apparent diffusion coefficient (ADC) of water is a reliable pathophysiological index of the viability of ischemic brain tissue. METHODS: Cerebral blood flow (CBF) and the cerebral metabolic rates of oxygen and glucose (CMRO2 and CMRglc, respectively) were measured using positron emission tomography (PET) scanning before and after permanent middle cerebral artery occlusion (MCAO) or reperfusion in pigs. The ADC value, which was measured using diffusion-weighted magnetic resonance (DW MR) imaging was compared with physiological variables obtained by PET scanning and with histological findings. After both permanent MCAO and reperfusion, the decrease in the ADC was significantly correlated with decrease in the CMRO2 and CMRglc. The infarction coincided with a CMRO2 threshold of 50% of the value measured on the contralateral side. Thus, an ADC value of 80% or 75% of the contralateral value reflected the CMRO2 threshold after permanent MCAO or reperfusion, respectively. On DW MR images, lesions with ADC values above 80% of the contralateral value are potentially reversible until 6 hours after MCAO, whereas lesions with ADC values below 75% of the contralateral value are irreversible as early as 2 hours after MCAO. CONCLUSIONS: The ADC of water provides a reliable pathophysiological index for tailoring therapy to the condition of individual stroke patients in clinical practice

    Standardization of Stroke Perfusion CT for Reperfusion Therapy

    No full text
    With the advances in terms of perfusion imaging, the "time is brain" approach used for acute reperfusion therapy in ischemic stroke patients is slowly being replaced by a "penumbra is brain" or "imaging is brain" approach. But the concept of penumbra-guided reperfusion therapy has not been validated. The lack of standardization in penumbral imaging is one of the main contributing factors for this absence of validation. This article reviews the issues underlying the lack of standardization of perfusion-CT for penumbra imaging, and offers avenues to remedy this situatio
    corecore