13 research outputs found

    Implementation of mercury biomonitoring in German adults using dried blood spot sampling in combination with direct mercury analysis

    Get PDF
    Venous blood is a preferred matrix for the determination of total mercury (Hg) in human biomonitoring but has some drawbacks such as the requirement for an uninterrupted cold chain for transport and storage and the need of medical personnel for sample collection. Therefore, we tested and implemented a simpler and less expensive method for measuring Hg in human blood using dried blood spots (DBS). For method development, we investigated the influence of different storage conditions (temperature, storage vessel, time) on DBS samples. For method validation, we compared DBS and venous blood and investigated whether DBS sampling is suitable for measuring Hg in the general population in countries with low Hg exposure such as Germany. Based on our results, we found that pre-cleaned glass tubes were most suitable for storage of DBS samples, as this allowed the samples to remain stable for at least 4~weeks even at high temperatures (40~°C). When comparing venous blood and DBS, a very good correlation (r = 0.95, p < 0.01, Spearman-Rho) and high precision of DBS (mean relative standard deviation 8.2% vs. 7.2% in venous blood samples) were observed. Comparing the recoveries of both matrices in different concentration ranges, the variation of the recoveries decreases with increasing Hg concentration. The mean recoveries also decreased with increasing Hg concentration. Overall, we found comparable results for DBS and venous~blood using direct Hg analysis. Furthermore, we demonstrated that DBS are suitable for Hg biomonitoring in the general population in Germany and improved the storage conditions for the DBS

    Conception and pilot testing of a self-management health application for patients with pollen-related allergic rhinitis and allergic asthma-the APOLLO app

    Get PDF
    Abstract It has been shown that pollen information services are an important self-management tool for patients with pollen-related allergic rhinitis (AR) and allergic asthma (AA). This study aimed to design an online application for patients with AR and AA, which supports patients to better manage their disease as well as to evaluate the app and present the first results of the pilot study. The pollen data were obtained from the electronic pollen information network of Bavaria, Germany. Participants were asked to fill in their allergy-related complaints in the app over a 60-day period. Subsequently, the app was evaluated. Indices and diagrams visualized the participants’ individual complaints as well as the daily pollen concentration in the air. In order to motivate participants to complete the app on a daily basis, we used elements of gamification. Two thirds of the participants (N = 46) reported feeling better informed about pollen counts and their allergy when using the app. The app's simple and comprehensible design was rated positively. More than 80% of the participants would recommend the app to their family and friends. The app can be a tool for patients with AR and AA to better understand their disease

    Effects of heat and personal protective equipment on thermal strain in healthcare workers: part B—application of wearable sensors to observe heat strain among healthcare workers under controlled conditions

    Get PDF
    Purpose As climate change accelerates, healthcare workers (HCW) are expected to be more frequently exposed to heat at work. Heat stress can be exacerbated by physical activity and unfavorable working requirements, such as wearing personal protective equipment (PPE). Thus, understanding its potential negative effects on HCW´s health and working performance is becoming crucial. Using wearable sensors, this study investigated the physiological effects of heat stress due to HCW-related activities. Methods Eighteen participants performed four experimental sessions in a controlled climatic environment following a standardized protocol. The conditions were (a) 22 °C, (b) 22 °C and PPE, (c) 27 °C and (d) 27 °C and PPE. An ear sensor (body temperature, heart rate) and a skin sensor (skin temperature) were used to record the participants´ physiological parameters. Results Heat and PPE had a significant effect on the measured physiological parameters. When wearing PPE, the median participants’ body temperature was 0.1 °C higher compared to not wearing PPE. At 27 °C, the median body temperature was 0.5 °C higher than at 22 °C. For median skin temperature, wearing PPE resulted in a 0.4 °C increase and higher temperatures in a 1.0 °C increase. An increase in median heart rate was also observed for PPE (+ 2/min) and heat (+ 3/min). Conclusion Long-term health and productivity risks can be further aggravated by the predicted temperature rise due to climate change. Further physiological studies with a well-designed intervention are needed to strengthen the evidence for developing comprehensive policies to protect workers in the healthcare sector

    Sun Exposure of Preschoolers, Parental Sun Protection Behavior, and Sun Protection Measures at Preschool in Bavaria—Comparison of Two Cross-Sectional Studies of 2010/11 and 2018/19

    Get PDF
    Introduction: Children’s skin is particularly susceptible to the carcinogenic effects of ultraviolet radiation. Young children are dependent on sun protection measures taken by parents and other caregivers. Objective: The aim of the study is to evaluate parental sun protection behavior and sun protection measures at preschool at 2 points in time (2010/11 and 2018/19) in Bavaria and to test for a secular trend.  Methods: Two cross-sectional surveys were carried out. For each survey, more than 4,000 parents of preschoolers completed a self-administered questionnaire about parental sun protection behavior and sun protection measures at preschool. To identify possible associations between parental sun protection behavior and sociodemographic characteristics, logistic regression analysis was carried out. Results: In the survey of 2018/19, 6 out of 8 sun protection measures are adequately applied by over two-thirds of the parents. Two out of 8 sun protection measures are adequately applied by less than one-third of the parents. Those 2 measures are aligning sun protection to actual UV index and preschoolers wearing sunglasses. The comparison of the study population of the survey of 2010/11 and of 2018/19 shows an improvement in parental sun protection behavior for 7 out of 8 sun protection measures. In both surveys more than 80% of parents state that preschool staff ensures preschoolers wearing sun hats and sunscreen outside on sunny days. Conclusion: Future campaigns should focus on the use of sunglasses and promote the UV index, as these sun protection measures are used very little

    Mercury biomonitoring in German adults using volumetric absorptive microsampling

    Get PDF
    Mercury (Hg) is a global pollutant and a danger to human health. Human biomonitoring of Hg using a dried blood matrix instead of venous blood sampling for exposure assessment is of growing interest. This study aims to develop, validate, and evaluate the application of volumetric absorptive microsampling (VAMS) for Hg biomonitoring in humans. Sampling, drying, and storage conditions were evaluated during method development. Storage in pre-cleaned glass vials after drying for 2 h in a desiccator ensured analyte stability for at least 4 weeks. Sixty-eight paired capillary VAMS and venous blood samples from volunteers in Munich, Germany, were used for method validation. Hg levels in VAMS and venous blood samples were determined by direct mercury analysis. The limits of detection and quantitation for VAMS were 0.18 and 0.61 mu g/l, respectively. However, sensitivity could be improved by using two microsamples for analysis instead of one. Hg levels in VAMS samples correlated very well with Hg levels in venous blood samples (R-2 = 0.958). Furthermore, VAMS showed a high accuracy (median recovery: 117%) and precision (median relative standard deviation: 8.7%), especially for Hg concentrations above 1.0 mu g/l. In fact, accuracy and precision of VAMS improved with increasing Hg concentrations. In conclusion, VAMS in combination with direct mercury analysis is an accurate and viable alternative for human biomonitoring of Hg
    corecore