7 research outputs found
Everolimus-Eluting Stents or Bypass Surgery for Left Main Coronary Artery Disease
Background Patients with obstructive left main coronary artery disease are usually treated with coronary-artery bypass grafting (CABG). Randomized trials have suggested that drug-eluting stents may be an acceptable alternative to CABG in selected patients with left main coronary disease. Methods We randomly assigned 1905 eligible patients with left main coronary artery disease of low or intermediate anatomical complexity to undergo either percutaneous coronary intervention (PCI) with fluoropolymer-based cobalt-chromium everolimus-eluting stents (PCI group, 948 patients) or CABG (CABG group, 957 patients). Anatomic complexity was assessed at the sites and defined by a Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery (SYNTAX) score of 32 or lower (the SYNTAX score reflects a comprehensive angiographic assessment of the coronary vasculature, with 0 as the lowest score and higher scores [no upper limit] indicating more complex coronary anatomy). The primary end point was the rate of a composite of death from any cause, stroke, or myocardial infarction at 3 years, and the trial was powered for noninferiority testing of the primary end point (noninferiority margin, 4.2 percentage points). Major secondary end points included the rate of a composite of death from any cause, stroke, or myocardial infarction at 30 days and the rate of a composite of death, stroke, myocardial infarction, or ischemia-driven revascularization at 3 years. Event rates were based on Kaplan-Meier estimates in time-to-first-event analyses. Results At 3 years, a primary end-point event had occurred in 15.4% of the patients in the PCI group and in 14.7% of the patients in the CABG group (difference, 0.7 percentage points; upper 97.5% confidence limit, 4.0 percentage points; P=0.02 for noninferiority; hazard ratio, 1.00; 95% confidence interval, 0.79 to 1.26; P=0.98 for superiority). The secondary end-point event of death, stroke, or myocardial infarction at 30 days occurred in 4.9% of the patients in the PCI group and in 7.9% in the CABG group (P<0.001 for noninferiority, P=0.008 for superiority). The secondary end-point event of death, stroke, myocardial infarction, or ischemia-driven revascularization at 3 years occurred in 23.1% of the patients in the PCI group and in 19.1% in the CABG group (P=0.01 for noninferiority, P=0.10 for superiority). Conclusions In patients with left main coronary artery disease and low or intermediate SYNTAX scores by site assessment, PCI with everolimus-eluting stents was noninferior to CABG with respect to the rate of the composite end point of death, stroke, or myocardial infarction at 3 years. (Funded by Abbott Vascular; EXCEL ClinicalTrials.gov number, NCT01205776 .)
Abstracts from the 20th International Symposium on Signal Transduction at the Blood-Brain Barriers
https://deepblue.lib.umich.edu/bitstream/2027.42/138963/1/12987_2017_Article_71.pd
In Vitro Transcription Amplification and Labeling Methods Contribute to the Variability of Gene Expression Profiling with DNA Microarrays
The effect of different amplification and labeling methods on DNA microarray expression results has not been previously delineated. To analyze the variation associated with widely accepted T7-based RNA amplificationand labeling methods, aliquots of the Stratagene Human Universal Reference RNA were labeled using three eukaryotic target preparation methods followed by uniform replicate array hybridization (Affymetrix U95Av2). Method-dependent variability was observed in the yield and size distribution of labeled products, as well as in the gene expression results. A significant increase in short transcripts, when compared to unamplified mRNA, was observed in methods with long in vitro transcription reactions. Intramethod reproducibility showed correlation coefficients >0.99, whereas intermethod comparisons showed coefficients ranging from 0.94 to 0.98 and a nearly twofold increase in coefficient of variation. Fold amplification for each method positively correlated with the number of genes present. Our experiments uncovered two factors that introduced significant bias in gene expression data: the number of labeled nucleotides, which introduces sequence-dependent bias, and the length of the in vitro transcription reaction, which introduces transcript size-dependent bias. This study provides evidence that variability in expression data may be caused, in part, by differences in amplification and labeling protocols