72 research outputs found

    Multiple Sterile Withdrawals from Iohexol Bottles Does Not Increase Contamination Risk

    Get PDF
    BACKGROUND: There is a global shortage of iohexol contrast media, commonly used in epidural injections, as a result of lockdown and decreased production due to COVID-19. Iohexol bottles are designated for single use, which, depending on the vials available, often leads to wasting up to 95% of this limited resource. However, avoiding multiple withdrawals may be unnecessary if withdrawing multiple times using sterile technique does not increase the risk for contamination. OBJECTIVES: The purpose of our study is to determine whether multiple withdrawals from iohexol injection bottles using a sterile technique poses a greater risk of introducing contaminants than a single withdrawal. Furthermore, we wish to determine the extent to which bacteria can survive and grow in the contrast media. STUDY DESIGN: Experimental. SETTING: Outpatient fluoroscopic suite and laboratory. METHODS: Twenty-one 100 mL 300 mg(iodine)/mL iohexol injection bottles, after one clinical use, were tested after the first and last withdrawals (withdrawal one and withdrawal 9 or 10) for bacterial and fungal specimens using culture media and 3M™ Petrifilms™. To determine the ability of methicillin-susceptible Staphylococcus aureus (MSSA) to survive or grow in the media, MSSA was added to different concentrations (0, 25, 50, 75, and 100%) of iohexol contrast media. RESULTS: There was no growth observed in cultures or on Petrifilms among the first and last draws of any of the samples. When bacteria were grown in different dilutions of the media, there was a significant, approximately one log decrease in counts from 0% contrast media to 100% contrast media (8.4 x 108 vs 5.6 x 107, P \u3c 0.01). LIMITATIONS: Our study is limited in the number of samples tested and would benefit from additional investigation before consideration of clinical application. CONCLUSIONS: Our results suggest that single-use 300 iohexol bottles may be reusable and that the contrast media is mildly antimicrobial, but not enough to retard contamination. In setting of shortages, contrast media bottles can safely be reused. This is valuable for conserving resources and limiting unnecessary health care-associated costs

    Killer cell Immunoglobulin-like receptor-ligand matching and outcomes after unrelated cord blood transplantation in acute myeloid leukemia

    Get PDF
    The effect of killer cell immunoglobulin-like receptor (KIR)-ligand matching on outcomes after unrelated cord blood (CB) transplantation was studied in 461 patients with acute myeloid leukemia, categorizing KIR ligand for HLA-C groups C1 and C2 and Bw4. Donor-recipient HLA matching considered allele-level matching at HLA-A, -B, -C, and -DRB1. Separate analyses were conducted for 6-7/8 HLA-matched and 3-5/8 HLA-matched transplants because HLA matching confounded KIR-ligand matching (ie, KIR-ligand mismatching was less likely with better HLA matching). All patients received single CB unit and myeloablative conditioning. There were no significant differences in nonrelapse mortality (NRM), relapse, and overall mortality by KIR-ligand match status. However, among recipients of 3-5/8 HLA-matched transplants, NRM (HR, 2.26; P = .008) and overall mortality (HR, 1.78; P = .008) but not relapse were higher with KIR-ligand mismatched (host-versus-graft direction) compared with KIR-ligand matched transplants. These data do not support selecting CB units based on KIR-ligand match status for transplants mismatched at 1 or 2 HLA loci. Although transplants mismatched at 3 or more HLA loci are not recommended, avoiding KIR-ligand mismatching in this setting lowers mortality risks

    A scoping review of penile implant biofilms-what do we know and what remains unknown?

    Get PDF
    Background: Penile prosthesis (PP) is a gold standard for treatment of erectile dysfunction given its reliability and efficacy. Infection remains the most feared complication of prosthetic surgery, which usually results in device removal, and places a significant economic burden on the healthcare system. While biofilms have shown to support the persistence of microorganisms, the degree by which this matrix is truly pathogenic remains unknown given its high prevalence even in asymptomatic patients. We aim to review and summarize the current literature pertaining to biofilm formation in the setting of PP surgeries in clinically infected and non-infected cases. Methods: Searches were performed in the MEDLINE online database through PubMed using a combination of keywords “penile prosthetic” OR “penile prosthesis” OR “penile implant” AND “biofilm” OR “revision” OR “removal” OR “infection” OR “explant”. Eleven articles met inclusion criteria. There were only three studies that explicitly listed the number of biofilms identified in their cohort, but we also included eight articles that mentioned swabbing and culturing of any bacterial biofilm during revision procedures for both clinically infected and non-infected implants. Results: Infected PP yielded a 11–100% rate of biofilm presence, while non-infected PP yielded a 3–70% rate of biofilm presence. Time to reoperation from initial PP placement were also largely variable, ranging from 2 weeks to over 2 years. Coagulase-negative staphylococcus (i.e., Staphylococcus epidermidis) were the most commonly reported organisms among non-infected implants, however, newer studies have identified a change towards more virulent organisms. Conclusions: Since the advent of PP surgery, diabetes control, revision washout protocols and antibiotic-impregnated devices have led to an overall decrease in biofilm formation and infectious complications. There is an overall paradigm shift in microbial profiles with more virulent organisms, such as Escherichia coli, Pseudomonas aeruginosa, Enterococcus species, and even fungal species beginning to replace the more common coagulase-negative staphylococcal species, especially in clinically infected implants. Additional studies are necessary to define the significance of bacterial presence in biofilms using impactful technologies such as next-generation sequencing. Currently, preliminary and experimental biofilm-control strategies are also underway to further address this clinical issue

    Systemic mastocytosis associated with t(8;21)(q22;q22) acute myeloid leukemia

    Get PDF
    Although KIT mutations are present in 20–25% of cases of t(8;21)(q22;q22) acute myeloid leukemia (AML), concurrent development of systemic mastocytosis (SM) is exceedingly rare. We examined the clinicopathologic features of SM associated with t(8;21)(q22;q22) AML in ten patients (six from our institutions and four from published literature) with t(8;21) AML and SM. In the majority of these cases, a definitive diagnosis of SM was made after chemotherapy, when the mast cell infiltrates were prominent. Deletion 9q was an additional cytogenetic abnormality in four cases. Four of the ten patients failed to achieve remission after standard chemotherapy and seven of the ten patients have died of AML. In the two patients who achieved durable remission after allogeneic hematopoietic stem cell transplant, recipient-derived neoplastic bone marrow mast cells persisted despite leukemic remission. SM associated with t(8;21) AML carries a dismal prognosis; therefore, detection of concurrent SM at diagnosis of t(8;21) AML has important prognostic implications

    How Does the Severity of Neuroforaminal Compression in Cervical Radiculopathy Affect Outcomes of Anterior Cervical Discectomy and Fusion

    Get PDF
    Study Design This study is a retrospective cohort study. Purpose This study aims to determine whether preoperative neuroforaminal stenosis (FS) severity is associated with motor function patient-reported outcome measures (PROMs) following anterior cervical discectomy and fusion (ACDF). Overview of Literature Cervical FS can significantly contribute to patient symptoms. While magnetic resonance imaging (MRI) has been used to classify FS, there has been limited research into the impact of FS severity on patient outcomes. Methods Patients undergoing primary, elective 1–3 level ACDF for radiculopathy at a single academic center between 2015 and 2021 were identified retrospectively. Cervical FS was evaluated using axial T2-weighted MRI images via a validated grading scale. The maximum degree of stenosis was used for multilevel disease. Motor symptoms were classified using encounters at their final preoperative and first postoperative visits, with examinations ≤3/5 indicating weakness. PROMs were obtained preoperatively and at 1-year follow-up. Bivariate analysis was used to compare outcomes based on stenosis severity, followed by multivariable analysis. Results This study included 354 patients, 157 with moderate stenosis and 197 with severe stenosis. Overall, 58 patients (16.4%) presented with upper extremity weakness ≤3/5. A similar number of patients in both groups presented with baseline motor weakness (13.5% vs. 16.55, p=0.431). Postoperatively, 97.1% and 87.0% of patients with severe and moderate FS, respectively, experienced full motor recovery (p=0.134). At 1-year, patients with severe neuroforaminal stenosis presented with significantly worse 12-item Short Form Survey Physical Component Score (PCS-12) (33.3 vs. 37.3, p=0.049) but demonstrated a greater magnitude of improvement (ΔPCS-12: 5.43 vs. 0.87, p=0.048). Worse stenosis was independently associated with greater ΔPCS-12 at 1-year (β=5.59, p=0.022). Conclusions Patients with severe FS presented with worse preoperative physical health. While ACDF improved outcomes and conferred similar motor recovery in all patients, those with severe FS reported much better improvement in physical function

    Awareness in Practice: Tensions in Access to Sensitive Attribute Data for Antidiscrimination

    Full text link
    Organizations cannot address demographic disparities that they cannot see. Recent research on machine learning and fairness has emphasized that awareness of sensitive attributes, such as race and sex, is critical to the development of interventions. However, on the ground, the existence of these data cannot be taken for granted. This paper uses the domains of employment, credit, and healthcare in the United States to surface conditions that have shaped the availability of sensitive attribute data. For each domain, we describe how and when private companies collect or infer sensitive attribute data for antidiscrimination purposes. An inconsistent story emerges: Some companies are required by law to collect sensitive attribute data, while others are prohibited from doing so. Still others, in the absence of legal mandates, have determined that collection and imputation of these data are appropriate to address disparities. This story has important implications for fairness research and its future applications. If companies that mediate access to life opportunities are unable or hesitant to collect or infer sensitive attribute data, then proposed techniques to detect and mitigate bias in machine learning models might never be implemented outside the lab. We conclude that today's legal requirements and corporate practices, while highly inconsistent across domains, offer lessons for how to approach the collection and inference of sensitive data in appropriate circumstances. We urge stakeholders, including machine learning practitioners, to actively help chart a path forward that takes both policy goals and technical needs into account
    • …
    corecore