10 research outputs found

    Long-term outcomes and prosthesis performance after transcatheter aortic valve replacement: results of self-expandable and balloon-expandable transcatheter heart valves

    Full text link
    BACKGROUND: Data on transcatheter aortic valve replacement (TAVR) long-term clinical outcomes and hemodynamic performance of the self-expandable CoreValve (CV) and the balloon-expandable Edwards SAPIEN XT (ES) (Edwards Lifesciences, Irvine, California, USA) transcatheter heart valves (THV) are limited. Therefore, this study aimed to compare long-term clinical outcome data and hemodynamic performance of TAVR with either CV or ES. METHODS: We reviewed prospectively collected data of 171 patients treated with TAVR for severe aortic stenosis (AS) at our center between June 2007 and December 2010, with last follow-up contact in 2016. RESULTS: Out of 171 patients treated with TAVR at our Institution, 87 received a CV and 84 an ES THV. Mean age was 81 [78-85] years, and mean Society of Thoracic Surgeons (STS) score was 7.5% (4.5-13.9%). Hemodynamic success by Valve Academic Research Consortium (VARC) definition was 97.1%. Mean trans-prosthetic gradient remained low and stable during follow-up in both groups (at 5-year 9.2±6.4 versus 12.7±5.1 mmHg, P=0.10). Late prosthesis failure occurred in 4 cases (2.4%). Thirty-day mortality was 4.7%, and estimated survival rates by Kaplan-Meyer after 1, 5 and 8 years were 87.6%, 44.9%, and 24.5%, respectively, without difference between THV groups. Rates of cardiovascular death, stroke, myocardial infarction (MI) and congestive heart failure (CHF) were also similar with CV and ES at long-term follow-up. History of CHF, pre-existent severe mitral regurgitation, paravalvular leak grade ≥2+, and chronic obstructive pulmonary disease were independent predictors of late mortality at multivariable analysis. CONCLUSIONS: Clinical and hemodynamic outcomes of patients treated by self-expandable CV or balloon-expandable ES THV were favorable and similar throughout long-term follow-up, with a rate of prosthesis failure of less than 3%

    TAVR with mechanically expandable prostheses: Is balloon aortic valvuloplasty really necessary?

    No full text
    BACKGROUND: The fully retrievable and repositionable Lotus Valve System uses a unique mechanical expansion mechanism. Balloon aortic valvuloplasty (BAV) is recommended before valve deployment. There are no studies focusing on feasibility and efficacy of Lotus Valve implantation without previous BAV. METHODS AND RESULTS: Thirty consecutive patients (63.3% female; mean age, 80\ub16.2years) underwent transcatheter aortic valve replacement (TAVR) with the Lotus Valve without preparatory BAV. Mean baseline aortic valve area was 0.41\ub10.14cm2/m2; mean transvalvular gradient was 50.2\ub116.2mmHg. All patients were successfully implanted, with 96.6% device success (VARC-2 definition) and 0% intra-procedural mortality. Partial and full valve repositioning were performed in 11 (36.7%) and 2 (6.7%) cases, respectively. Mean 30-day transprosthetic gradient was 11.3\ub13.6mmHg, with an effective aortic orifice area of 1.0\ub10.2cm2/m2, and more than mild paravalvular leakage (PVL) in only one patient. At 30days, cardiac mortality was 3.3%, and 96.3% of subjects were NYHA Class I or II. The rate of life-threatening bleeding was 10%; one patient experienced disabling stroke. Ten patients underwent new pacemaker implantation (38%). CONCLUSIONS: TAVR with the mechanically expandable Lotus Valve seems feasible without performing preparatory BAV. Valve hemodynamics at 30-days were favorable, and clinical outcomes were similar to studies employing routine preparatory BAV

    Unravelling the (arte)fact of increased pacemaker rate with the Edwards SAPIEN 3 valve

    No full text
    none11Early data on the Edwards SAPIEN 3 valve (S3-THV) have shown low rates of paravalvular leaks and vascular complications but relatively high 30-day permanent pacemaker implantation (PPMI) rates. No direct comparisons on clinical outcomes including PPMI rates are available for the S3-THV and the Edwards SAPIEN XT (XT-THV). We aimed to compare the 30-day PPMI rates in patients treated with the two prostheses and to assess the interplay among valve type, depth of implantation and PPMI rate.mixedTarantini, Giuseppe; Mojoli, Marco; Purita, Paola; Napodano, Massimo; D'Onofrio, Augusto; Frigo, Annachiara; Covolo, Elisa; Facchin, Michela; Isabella, Giambattista; Gerosa, Gino; Iliceto, SabinoTarantini, Giuseppe; Mojoli, MARCO ALBERTO; Purita, PAOLA ANGELA MARIA; Napodano, Massimo; D'Onofrio, Augusto; Frigo, ANNA CHIARA; Covolo, Elisa; Facchin, Michela; Isabella, Giambattista; Gerosa, Gino; Iliceto, Sabin

    Long-term outcomes and prosthesis performance after transcatheter aortic valve replacement: Results of self-expandable and balloon-expandable transcatheter heart valves

    No full text
    BACKGROUND: Data on transcatheter aortic valve replacement (TAVR) long-term clinical outcomes and hemodynamic performance of the self-expandable CoreValve (CV) and the balloon-expandable Edwards SAPIEN XT (ES) (Edwards Lifesciences, Irvine, California, USA) transcatheter heart valves (THV) are limited. Therefore, this study aimed to compare long-term clinical outcome data and hemodynamic performance of TAVR with either CV or ES. METHODS: We reviewed prospectively collected data of 171 patients treated with TAVR for severe aortic stenosis (AS) at our center between June 2007 and December 2010, with last follow-up contact in 2016. RESULTS: Out of 171 patients treated with TAVR at our Institution, 87 received a CV and 84 an ES THV. Mean age was 81 [78-85] years, and mean Society of Thoracic Surgeons (STS) score was 7.5% (4.5-13.9%). Hemodynamic success by Valve Academic Research Consortium (VARC) definition was 97.1%. Mean trans-prosthetic gradient remained low and stable during follow-up in both groups (at 5-year 9.2±6.4 versus 12.7±5.1 mmHg, P=0.10). Late prosthesis failure occurred in 4 cases (2.4%). Thirty-day mortality was 4.7%, and estimated survival rates by Kaplan-Meyer after 1, 5 and 8 years were 87.6%, 44.9%, and 24.5%, respectively, without difference between THV groups. Rates of cardiovascular death, stroke, myocardial infarction (MI) and congestive heart failure (CHF) were also similar with CV and ES at long-term follow-up. History of CHF, pre-existent severe mitral regurgitation, paravalvular leak grade ≥2+, and chronic obstructive pulmonary disease were independent predictors of late mortality at multivariable analysis. CONCLUSIONS: Clinical and hemodynamic outcomes of patients treated by self-expandable CV or balloon-expandable ES THV were favorable and similar throughout long-term follow-up, with a rate of prosthesis failure of less than 3%

    Transcatheter treatment of native aortic valve regurgitation:Results from an international registry using the transfemoral ACURATE neo valve

    No full text
    Background: Transcatheter aortic valve replacement (TAVR) has been validated for the treatment of severe symptomatic aortic stenosis in patients at high and intermediate surgical risk. Recently, TAVR has been proposed as an alternative to medical therapy in inoperable patients with severe native aortic valve regurgitation (NAVR). This multicenter international registry sought to evaluate safety and efficacy of TAVR with the self-expandable ACURATE neo valve in a cohort of patients with NAVR.Methods: A total of 24 patients with severe NAVR treated by TAVR between September 2016 and October 2018 in 13 European centers were included. Clinical, procedural and follow up data were inserted in a dedicated database. Outcomes were codified according to Valve Academic Research Consortium-2 criteria.Results: Mean age was 79.4 years, 58.4% were female. Mean EuroSCORE II and STS score were 5% and 3.9%, respectively. Device success was 87.5%. Moderate paravalvular leak (PVL) was found in two (8.3%) of patients, both with a perimeter oversizing index <10%. Implantation of a second device was necessary in three cases (12.5%), one for severe PVL and two for device displacement. New pacemaker implantation rate was 21.1%. At 30 days, stroke and all-cause mortality rates were 0% and 4.1%, respectively.Conclusions: This multicenter study suggests good feasibility and early safety of transfemoral TAVR with the self-expandable ACURATE neo device in patients with severe NAVR refused for surgery. Rates of moderate PVL, new pacemaker implantation and need for a second valve were higher than those reported for TAVR in aortic stenosis. (C) 2020 The Authors. Published by Elsevier B.V

    Takotsubo Syndrome during COVID-19 Pandemic in the Veneto Region, Italy

    No full text
    Background: During the COVID-19 pandemic, the risk of SARS-CoV-2 infection, the public health measures of social distancing, the freedom limitations, quarantine, and the enforced homeworking under the lockdown period, as well as medical causes including COVID-19 infection per se, may have caused major emotional distress, especially in the most vulnerable patients. We aimed to evaluate the variations in the number of admissions due to Takotsubo syndrome (TTS) during the COVID-19 pandemic in the Veneto region. Methods: We retrospectively reviewed and analyzed the number of admissions because of TTS in 13 Divisions of Cardiology located in the Veneto region, the northeastern area of Italy, covering a population of more than 2.5 million inhabitants, during the two major pandemic waves of COVID-19 (the first between 15 March and 30 April 2020 and the second between 15 November and 30 December 2020) that occurred in 2020. Results: In total, 807 acute coronary syndromes were admitted in the 13 enrolling hospitals. Among these, 3.9% had TTS. Compared to the corresponding 2018 and 2019 time periods, we observed a significant increase in the number of TTS cases (+15.6%, p = 0.03 and +12.5%, p = 0.04, comparing 2018 to 2020 and 2019 to 2020, respectively). Geographical distribution of the TTS cases reflected the broad spread of the SARS-CoV-2 infection with a significant direct relationship between TTS incidence and the number of COVID-19 infections according to Pearson&rsquo;s correlation (r = 0.798, p &lt; 0.001). Conclusions: The higher incidence of TTS during the 2020 COVID-19 pandemic waves, especially in the areas that were hit hardest in terms of morbidity and mortality by the SARS-CoV-2 infection, suggest a strong direct and/or indirect role of COVID-19 in the pathogenesis of TTS

    Decline of Admission for Acute Coronary Syndromes and Acute Cardiovascular Conditions during COVID-19 Pandemic in Veneto Region

    No full text
    Background: The present study aimed to examine longitudinal trends in hospitalizations for acute coronary syndrome (ACS) before and during the COVID-19 pandemic, by reviewing the data from 13 hospitals of the Veneto Region, in the north-east of Italy. Methods: We performed a multicenter, retrospective analysis including all the consecutive patients presenting with ACS and other acute cardiovascular (CV) conditions (defined as heart failure, arrhythmias, cardiac arrest and venous thromboembolism) hospitalized in 13 different hospitals of the Veneto Region covering a population of 2,554,818 inhabitants, during the first (between 15 March 2020 and 30 April 2020) and second (between 15 November 2020 and 30 December 2020) COVID-19 pandemic waves (the 2020 cohort). Data were compared with those obtained at the same time-windows of years 2018 and 2019 (the historical cohorts). Results: Compared to the historical cohorts, a significant decrease in the number of ACS cases was observed in 2020 (&minus;27.3%, p = 0.01 and &minus;32%, p &lt; 0.001, comparing 2018 versus 2020 and 2019 and 2020, respectively). The proportion of patients hospitalized for acute CV conditions decreased during the first and second wave COVID-19 pandemic when compared to the historical cohorts (&minus;36.5%, p &lt; 0.001 and &minus;40.6%, p &lt; 0.001, comparing 2018 versus 2020 and 2019 and 2020, respectively). Pearson&rsquo;s correlation evidenced a significant inverse relationship between the number of COVID-19 cases and both ACS hospital admissions (r = &minus;0.881, p = 0.005) and hospitalizations for acute CV conditions (r = &minus;0.738, p = 0.01), respectively. Conclusions: The decrease in hospitalizations for ACS and other acute CV conditions will strongly affect future patients&rsquo; management since undiagnosed nonfatal CV events represent a source of increased (and unknown) CV morbidity and mortality

    Delayed Coronary Obstruction After Transcatheter Aortic Valve Replacement

    Get PDF
    BACKGROUND: Delayed coronary obstruction (DCO) is an uncommon and barely reported complication following transcatheter aortic valve replacement (TAVR). OBJECTIVES: The aim of this study was to describe the incidence and pathophysiological features of DCO after TAVR, obtained from a large international multicenter registry. METHODS: Data were retrospectively collected from an international multicenter registry consisting of 18 centers between November 2005 and December 2016. RESULTS: During the study period, 38 DCO (incidence 0.22%) cases were identified from a total of 17,092 TAVR procedures. DCO occurred more commonly after valve-in-valve procedures (0.89% vs. 0.18%; p < 0.001) and if self-expandable valves were used during the index procedure (0.36% vs. 0.11% balloon expandable; p < 0.01). DCO was most likely to occur 6424 h after the TAVR procedure (47.4%; n = 18); 6 (15.8%) cases occurred between 24 h and 647 days, with the remaining 14 (36.8%) at 6560 days. The most frequent presentation was cardiac arrest (31.6%; n = 12), followed by ST-segment elevation myocardial infarction (23.7%; n = 9). The left coronary artery was obstructed in most cases (92.1%; n = 35). Percutaneous coronary intervention was attempted in the majority of cases (74.3% left main; 60% right coronary), and stent implantation was successful in 68.8%. The overall in-hospital death rate was 50% (n = 19), and was higher if DCO occurred 647 days from the index procedure (62.5% vs. 28.6%; p = 0.09). CONCLUSIONS: DCO following TAVR is a rare phenomenon that is associated with a high in-hospital mortality rate. Clinicians should be aware that coronary obstruction can occur after the original TAVR procedure and have a low threshold for performing coronary angiography when clinically suspected

    Feasibility of Coronary Access in Patients With Acute Coronary Syndrome and Previous TAVR.

    No full text
    OBJECTIVES The aim of this study was to characterize the feasibility of coronary angiography (CA) and percutaneous coronary intervention (PCI) in acute settings among patients who have undergone transcatheter aortic valve replacement (TAVR). BACKGROUND Impaired coronary access after TAVR may be challenging and particularly in acute settings could have deleterious consequences. METHODS In this international registry, data from patients with prior TAVR requiring urgent or emergent CA were retrospectively collected. A total of 449 patients from 25 sites with acute coronary syndromes (89.1%) and other acute cardiovascular situations (10.9%) were included. RESULTS Success rates were high for CA of the right coronary artery (98.3%) and left coronary artery (99.3%) and were higher among patients with short stent-frame prostheses (SFPs) than in those with long SFPs for CA of the right coronary artery (99.6% vs 95.9%; P = 0.005) but not for CA of the left coronary artery (99.7% vs 98.7%; P = 0.24). PCI of native coronary arteries was successful in 91.4% of cases and independent of valve type (short SFP 90.4% vs long SFP 93.4%; P = 0.44). Guide engagement failed in 6 patients, of whom 3 underwent emergent coronary artery bypass grafting and another 3 died in the hospital. Among patients requiring revascularization of native vessels, independent predictors of 30-day all-cause mortality were prior diabetes, cardiogenic shock, and failed PCI but not valve type or success of coronary engagement. CONCLUSIONS CA or PCI after TAVR in acute settings is usually successful, but selective coronary engagement may be more challenging in the presence of long SFPs. Among patients requiring PCI, prior diabetes, cardiogenic shock, and failed PCI were predictors of early mortality

    Incidence and outcome of peri-procedural transcatheter heart valve embolization and migration: the TRAVEL registry (TranscatheteR HeArt Valve EmboLization and Migration)

    No full text
    Aims Peri-procedural transcatheter valve embolization and migration (TVEM) is a rare but potentially devastating complication of transcatheter aortic valve implantation (TAVI). We sought to assess the incidence, causes, and outcome of TVEM in a large multicentre cohort. Methods and results We recorded cases of peri-procedural TVEM in patients undergoing TAVI between January 2010 and December 2017 from 26 international sites. Peri-procedural TVEM occurred in 273/29 636 (0.92%) TAVI cases (age 80.8 +/- 7.3 years; 53.8% female), of which 217 were to the ascending aorta and 56 to the left ventricle. The use of self-expanding or first-generation prostheses and presence of a bicuspid aortic valve were independent predictors of TVEM. Bail-out measures included repositioning attempts using snares or miscellaneous tools (41.0%), multiple valve implantations (83.2%), and conversion to surgery (19.0%). Using 1:4-propensity matching, we identified a cohort of 235 patients with TVEM (TVEMPS) and 932 patients without TVEM (non-TVEMPS). In the matched cohort, all-cause mortality was higher in TVEMPS than in non-TVEMPS at 30 days (18.6% vs. 4.9%; P < 0.001) and after 1 year (30.5% vs. 16.6%; P < 0.001). Major stroke was more frequent in TVEMPS at 30 days (10.6% vs. 2.8%; P < 0.001), but not at 1 year (4.6% vs. 1.9%; P = 0.17). The need for emergent cardiopulmonary support, major stroke at 30 days, and acute kidney injury Stages 2 and 3 increased the risk of 1-year mortality, whereas a better renal function at baseline was protective. Conclusion Transcatheter valve embolization and migration occurred in approximately 1% and was associated with increased morbidity and mortality
    corecore