12 research outputs found
The Impact of a Post-Prescription Review and Feedback Antimicrobial Stewardship Program in Lebanon
Antimicrobial stewardship programs (ASPs) are effective means to optimize prescribing practices. They are under-utilized in the Middle East where many challenges exist for ASP implementation. We assessed the effectiveness of infectious disease physician-driven post-prescription review and feedback as an ASP in Lebanon. This prospective cohort study was conducted over an 18-month period in the medical, surgical, and intensive care units of a tertiary care hospital. It consisted of three phases: the baseline, intervention, and follow-up. There was a washout period of two months between each phase. Patients aged ≥16 years receiving 48 h of antibiotics were included. During the intervention phase, the AMS team reviewed antimicrobial use within 72 h post-prescription and gave alternate recommendations based on the guidelines for use. The acceptance of the recommendations was measured at 72 h. The primary outcome of the study was days of therapy per 1000 study patient days. A total of 328 patients were recruited in the baseline phase (August-October 2020), 467 patients in the intervention phase (January-June 2021), and 301 patients in the post-intervention phase (September-December 2021). The total days of therapy decreased from 11.46 during the baseline phase to 8.64 during the intervention phase (p \u3c 0.001). Intervention acceptance occurred 88.5% of the time. The infectious disease physician-driven implementation of an ASP was successful in reducing antibiotic utilization in an acute care setting in Lebanon
Recommended from our members
Business 101 for Audiology: Business Principles and Clinical Productivity
Differences in Perception of Musical Stimuli among Acoustic, Electric, and Combined Modality Listeners
Background: Cochlear implants have shown vast improvements in speech understanding for those with severe to profound hearing loss; however, music perception remains a challenge for electric hearing. It is unclear whether the difficulties arise from limitations of sound processing, the nature of a damaged auditory system, or a combination of both.
Purpose: To examine music perception performance with different acoustic and electric hearing configurations.
Research Design: Chord discrimination and timbre perception were tested in subjects representing four daily-use listening configurations: unilateral cochlear implant (Cl), contralateral bimodal (CI HA), bilateral hearing aid (HAHA) and normal-hearing (NH) listeners. A same-different task was used for discrimination of two chords played on piano. Timbre perception was assessed using a 10-instrument forced-choice identification task.
Study Sample: Fourteen adults were included in each group, none of whom were professional musicians.
Data Collection and Analysis: The number of correct responses was divided by the total number of presentations to calculate scores in percent correct. Data analyses were performed with Kruskal-Wallis one-way analysis of variance and linear regression.
Results: Chord discrimination showed a narrow range of performance across groups, with mean scores ranging between 72.5% (Cl) and 88.9% (NH). Significant differences were seen between the NH and all hearing-impaired groups. Both the NAHA and CIHA groups performed significantly better than the Cl groups, and no significant differences were observed between the HAHA and CI HA groups. Timbre perception was significantly poorer for the hearing-impaired groups (mean scores ranged from 50.3-73.9%) compared to NH (95.2%). Significantly better performance was observed in the HAHA group as compared to both groups with electric hearing (Cl and CIHA). There was no significant difference in performance between the CIHA and Cl groups. Timbre perception was a significantly more difficult task than chord discrimination for both the Cl and CIHA groups, yet the easier task for the NH group. A significant difference between the two tasks was not seen in the HAHA group.
Conclusion: Having impaired hearing decreases performance compared to NH across both chord discrimination and timbre perception tasks. For chord discrimination, having acoustic hearing improved performance compared to electric hearing only. Timbre perception distinguished those with acoustic hearing from those with electric hearing. Those with bilateral acoustic hearing, even if damaged, performed significantly better on this task than those requiring electrical stimulation, which may indicate that Cl sound processing fails to capture and deliver the necessary acoustic cues for timbre perception. Further analysis of timbre characteristics in electric hearing may contribute to advancements in programming strategies to obtain optimal hearing outcomes
Recommended from our members
Decoding Billing Practices in Cochlear Implant Programs
The purpose of this study was to examine current cochlear implant (CI) billing practices across CI audiologists in the United States, to determine if CI audiologists are following the National Correct Coding Initiative (NCCI) edits, and to assess the CI audiologist's exposure to billing education.
A 48-question survey was electronically distributed to and completed by audiologists who bill for CI services. Demographic data including work setting, population served, years of experience, number of CI patients managed per week, and exposure to billing education were collected. Data were analyzed to identify codes and modifiers used to bill for commonly performed CI procedures such as unilateral and bilateral CI programming, preoperative and postoperative testing, and objective measures.
Data were obtained from 96 audiologists. The majority (86.3%, n = 82) of respondents agreed or strongly agreed they understand billing and coding practices for cochlear implants and 94.7% (n = 89) rated themselves as somewhat to highly efficient when performing these practices. Only 16.8% (n = 16) of respondents reported receiving formal training for practice management, and half of the respondents (51.1%, n = 48) reported unfamiliarity with national billing guidelines. Those who received formal training reported higher billing efficiency. Wide variability was seen for various billing scenarios. Billing questions were presented, and answers were coded as correct or incorrect based on the NCCI edits. Respondents who reported higher agreement with understanding billing and who received formal training scored better on common billing questions related to the NCCI edits.
Most CI audiologists rated themselves as efficient in billing; however, wide variance in billing practices was observed. Incorporating practice management and current billing education into daily practice and into audiology training programs is essential to clinic efficiency, practice management, and CI program viability. CI audiologists should be knowledgeable about appropriate billing practices to ensure long-term sustainability of programs
Temporal and spectral contributions to musical instrument identification and discrimination among cochlear implant users
AbstractObjectiveTo investigate the contributions of envelope and fine-structure to the perception of timbre by cochlear implant (CI) users as compared to normal hearing (NH) listeners.MethodsThis was a prospective cohort comparison study. Normal hearing and cochlear implant patients were tested. Three experiments were performed in sound field using musical notes altered to affect the characteristic pitch of an instrument and the acoustic envelope. Experiment 1 assessed the ability to identify the instrument playing each note, while experiments 2 and 3 assessed the ability to discriminate the different stimuli.ResultsNormal hearing subjects performed better than CI subjects in all instrument identification tasks, reaching statistical significance for 4 of 5 stimulus conditions. Within the CI population, acoustic envelope modifications did not significantly affect instrument identification or discrimination. With envelope and pitch cues removed, fine structure discrimination performance was similar between normal hearing and CI users for the majority of conditions, but some specific instrument comparisons were significantly more challenging for CI users.ConclusionsCochlear implant users perform significantly worse than normal hearing listeners on tasks of instrument identification. However, cochlear implant listeners can discriminate differences in envelope and some fine structure components of musical instrument sounds as well as normal hearing listeners. The results indicated that certain fine structure cues are important for cochlear implant users to make discrimination judgments, and therefore may affect interpretation toward associating with a specific instrument for identification
Recommended from our members
Electrophysiology and genetic testing in the precision medicine of congenital deafness: A review
Congenital hearing loss is remarkably heterogeneous, with over 130 deafness genes and thousands of variants, making for innumerable genotype/phenotype combinations. Understanding both the pathophysiology of hearing loss and molecular site of lesion along the auditory pathway permits for significantly individualized counseling. Electrophysiologic techniques such as electrocochleography (ECochG) and electrically-evoked compound action potentials (eCAP) are being studied to localize pathology and estimate residual cochlear vs. neural health. This review describes the expanding roles of genetic and electrophysiologic evaluation in the precision medicine of congenital hearing loss.
The basics of genetic mutations in hearing loss and electrophysiologic testing (ECochG and eCAP) are reviewed, and how they complement each other in the diagnostics and prognostication of hearing outcomes. Used together, these measures improve the understanding of insults to the auditory system, allowing for individualized counseling for CI candidacy/outcomes or other habilitation strategies.
Despite tremendous discovery in deafness genes, the effects of individual genes on neural function remain poorly understood. Bridging the understanding between molecular genotype and neural and functional phenotype is paramount to interpreting genetic results in clinical practice. The future hearing healthcare provider must consolidate an ever-increasing amount of genetic and phenotypic information in the precision medicine of hearing loss
Recommended from our members
Catchment Profile of Large Cochlear Implant Centers in the United States
Objective To characterize the catchment area and patient profile of large cochlear implant (CI) centers in the United States. Study Design Multi-institutional retrospective case series. Setting Tertiary referral CI centers. Methods Patients who underwent CI surgery at 7 participating CI centers between 2015 and 2020 were identified. Patients' residential zip codes were used to approximate travel distances and urban vs rural residential areas. Results Over the 6-year study period (2015-2020), 6313 unique CI surgical procedures occurred (4529 adult, 1784 pediatric). Between 2015 and 2019, CI procedures increased by 43%. Patients traveled a median 52 miles (interquartile range, 21-110) each way; patients treated at rural CI centers traveled greater distances vs those treated at urban centers (72 vs 46 miles, P < .001). Rural residents represented 61% of the patient population and traveled farther than urban residents (73 vs 24 miles, P < .001). Overall, 91% of patients lived within a 200-mile radius of the institution, while 71% lived within a 100-mile radius. In adults, multiple regression analysis redemonstrated an association between greater travel distances and (1) older age at the time of CI and (2) residential rural setting (both P < .001, r(2) = 0.2). Conclusions While large CI centers serve geographically dispersed populations, most patients reside within a 200-mile radius. Strategies to expand CI utilization may leverage remote programming, telemedicine, and strategic placement of new centers and satellite clinics to ameliorate travel burden
Multicenter US Clinical Trial With an Electric-Acoustic Stimulation (EAS) System in Adults: Final Outcomes.
OBJECTIVE: To demonstrate the safety and effectiveness of the MED-EL Electric-Acoustic Stimulation (EAS) System, for adults with residual low-frequency hearing and severe-to-profound hearing loss in the mid to high frequencies.
STUDY DESIGN: Prospective, repeated measures.
SETTING: Multicenter, hospital.
PATIENTS: Seventy-three subjects implanted with PULSAR or SONATA cochlear implants with FLEX electrode arrays.
INTERVENTION: Subjects were fit postoperatively with an audio processor, combining electric stimulation and acoustic amplification.
MAIN OUTCOME MEASURES: Unaided thresholds were measured preoperatively and at 3, 6, and 12 months postactivation. Speech perception was assessed at these intervals using City University of New York sentences in noise and consonant-nucleus-consonant words in quiet. Subjective benefit was assessed at these intervals via the Abbreviated Profile of Hearing Aid Benefit and Hearing Device Satisfaction Scale questionnaires.
RESULTS: Sixty-seven of 73 subjects (92%) completed outcome measures for all study intervals. Of those 67 subjects, 79% experienced less than a 30 dB HL low-frequency pure-tone average (250-1000 Hz) shift, and 97% were able to use the acoustic unit at 12 months postactivation. In the EAS condition, 94% of subjects performed similarly to or better than their preoperative performance on City University of New York sentences in noise at 12 months postactivation, with 85% demonstrating improvement. Ninety-seven percent of subjects performed similarly or better on consonant-nucleus-consonant words in quiet, with 84% demonstrating improvement.
CONCLUSION: The MED-EL EAS System is a safe and effective treatment option for adults with normal hearing to moderate sensorineural hearing loss in the low frequencies and severe-to-profound sensorineural hearing loss in the high frequencies who do not benefit from traditional amplification
Recommended from our members
Amplitude Parameters Are Predictive of Hearing Preservation in a Randomized Controlled Trial of Intracochlear Electrocochleography During Cochlear Implant Surgery
To prospectively evaluate the association between hearing preservation after cochlear implantation (CI) and intracochlear electrocochleography (ECochG) amplitude parameters.OBJECTIVETo prospectively evaluate the association between hearing preservation after cochlear implantation (CI) and intracochlear electrocochleography (ECochG) amplitude parameters.Multi-institutional, prospective randomized clinical trial.STUDY DESIGNMulti-institutional, prospective randomized clinical trial.Ten high-volume, tertiary care CI centers.SETTINGTen high-volume, tertiary care CI centers.Adults (n = 87) with sensorineural hearing loss meeting CI criteria (2018-2021) with audiometric thresholds of ≤80 dB HL at 500 Hz.PATIENTSAdults (n = 87) with sensorineural hearing loss meeting CI criteria (2018-2021) with audiometric thresholds of ≤80 dB HL at 500 Hz.Participants were randomized to CI surgery with or without audible ECochG monitoring. Electrode arrays were inserted to the full-depth marker. Hearing preservation was determined by comparing pre-CI, unaided low-frequency (125-, 250-, and 500-Hz) pure-tone average (LF-PTA) to LF-PTA at CI activation. Three ECochG amplitude parameters were analyzed: 1) insertion track patterns, 2) magnitude of ECochG amplitude change, and 3) total number of ECochG amplitude drops.METHODSParticipants were randomized to CI surgery with or without audible ECochG monitoring. Electrode arrays were inserted to the full-depth marker. Hearing preservation was determined by comparing pre-CI, unaided low-frequency (125-, 250-, and 500-Hz) pure-tone average (LF-PTA) to LF-PTA at CI activation. Three ECochG amplitude parameters were analyzed: 1) insertion track patterns, 2) magnitude of ECochG amplitude change, and 3) total number of ECochG amplitude drops.The Type CC insertion track pattern, representing corrected drops in ECochG amplitude, was seen in 76% of cases with ECochG "on," compared with 24% of cases with ECochG "off" (p = 0.003). The magnitude of ECochG signal drop was significantly correlated with the amount of LF-PTA change pre-CI and post-CI (p < 0.05). The mean number of amplitude drops during electrode insertion was significantly correlated with change in LF-PTA at activation and 3 months post-CI (p ≤ 0.01).RESULTSThe Type CC insertion track pattern, representing corrected drops in ECochG amplitude, was seen in 76% of cases with ECochG "on," compared with 24% of cases with ECochG "off" (p = 0.003). The magnitude of ECochG signal drop was significantly correlated with the amount of LF-PTA change pre-CI and post-CI (p < 0.05). The mean number of amplitude drops during electrode insertion was significantly correlated with change in LF-PTA at activation and 3 months post-CI (p ≤ 0.01).ECochG amplitude parameters during CI surgery have important prognostic utility. Higher incidence of Type CC in ECochG "on" suggests that monitoring may be useful for surgeons in order to recover the ECochG signal and preventing potentially traumatic electrode-cochlear interactions.CONCLUSIONSECochG amplitude parameters during CI surgery have important prognostic utility. Higher incidence of Type CC in ECochG "on" suggests that monitoring may be useful for surgeons in order to recover the ECochG signal and preventing potentially traumatic electrode-cochlear interactions