95 research outputs found

    Eliminating the "Pitfalls" of chronic indwelling central venous access device placement in cancer patients by utilizing a venous cutdown approach and by selectively and appropriately utilizing intraoperative venography

    Get PDF
    There are several very obvious and simple solutions for eliminating the "Pitfalls" and for minimizing the risk of occurrence of any perioperative complications associated with placement of chronic indwelling central venous access devices in cancer patients. The first is the utilization of a venous cutdown approach, such as the cephalic vein or the external jugular vein, which essentially eliminates potentially life-threatening perioperative complications, such as pneumothorax and injury to the great vessels (with or without associated hemothorax). The second is the selective and appropriate utilization of intraoperative venography for defining the central venous anatomy and for providing a venous roadmap in those particularly challenging cases in which difficulties are encountered during chronic indwelling central venous access device placement

    The utilization of an ultrasound-guided 8-gauge vacuum-assisted breast biopsy system as an innovative approach to accomplishing complete eradication of multiple bilateral breast fibroadenomas

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ultrasound-guided vacuum-assisted breast biopsy technology is extremely useful for diagnostic biopsy of suspicious breast lesions and for attempted complete excision of appropriately selected presumed benign breast lesions.</p> <p>Case presentation</p> <p>A female patient presented with 16 breast lesions (eight within each breast), documented on ultrasound and all presumed to be fibroadenomas. Over a ten and one-half month period of time, 14 of these 16 breast lesions were removed under ultrasound guidance during a total of 11 separate 8-gauge Mammotome<sup>® </sup>excision procedures performed during seven separate sessions. Additionally, two of these 16 breast lesions were removed by open surgical excision. A histopathologic diagnosis of fibroadenoma and/or fibroadenomatous changes was confirmed at all lesion excision sites. Interval follow-up ultrasound imaging revealed no evidence of a residual lesion at the site of any of the 16 original breast lesions.</p> <p>Conclusion</p> <p>This report describes an innovative approach of utilizing ultrasound-guided 8-gauge vacuum-assisted breast biopsy technology for assisting in achieving complete eradication of multiple bilateral fibroadenomas in a patient who presented with 16 documented breast lesions. As such, this innovative approach is highly recommended in similar appropriately selected patients.</p

    Re-emphasizing the concept of adequacy of intraoperative assessment of the axillary sentinel lymph nodes for identifying nodal positivity during breast cancer surgery

    Get PDF
    BACKGROUND: Although sentinel lymph node (SLN) biopsy is a standard of care for the evaluation of the axillary lymph nodes during breast cancer surgery, a substantial degree of variation exists among individual surgeons as to what represents an adequate assessment. The aim of the current study was to assess when metastatic disease was first identified within consecutively harvested SLN candidates for invasive breast cancers demonstrating a positive SLN. METHODS: We retrospectively analyzed a series of 400 breast cancers from a recently published prospective randomized clinical trial. A combined radiocolloid and blue dye technique was used. All potential SLN candidates, containing counts of at least 10% of the hottest SLN and/or containing blue dye, were harvested and were consecutively numbered in the order of the decreasing level of counts (with the hottest SLN representing SLN #1). RESULTS: Among 371 invasive breast cancers, a SLN was identified within 353 cases (95%). Mean number of SLNs identified was 2.5 (range, 1 to 9), with a single SLN identified in 104 (29%) cases, two identified in 110 (31%), three identified in 73 (21%), four identified in 35 (10%), five identified in 16 (5%), and six or more identified in 15 (4%). A positive SLN was found in 104 (29%) cases. SLN #1 was the first positive SLN in 86 (83%). SLN #2 was the first positive SLN in 15 (14%). SLN #3, SLN #4, and SLN #5 were the first positive SLN in one case (1%) each. A positive SLN was found in 18% (19/104) of cases when a single SLN was identified, as compared to in 34% (85/249) when two or more SLNs were identified (P = 0.003). CONCLUSION: The accurate and optimal assessment of the axilla during breast cancer surgery requires persistence and diligence for attempting to identify all potential SLN candidates in order to avoid failing to recognize a positive SLN. The scenario in which only a single negative SLN candidate is intraoperatively identified is one that should raise some concern to the operating surgeon

    Persistent left superior vena cava: Review of the literature, clinical implications, and relevance of alterations in thoracic central venous anatomy as pertaining to the general principles of central venous access device placement and venography in cancer patients

    Get PDF
    Persistent left superior vena cava (PLSVC) represents the most common congenital venous anomaly of the thoracic systemic venous return, occurring in 0.3% to 0.5% of individuals in the general population, and in up to 12% of individuals with other documented congential heart abnormalities. In this regard, there is very little in the literature that specifically addresses the potential importance of the incidental finding of PLSVC to surgeons, interventional radiologists, and other physicians actively involved in central venous access device placement in cancer patients. In the current review, we have attempted to comprehensively evaluate the available literature regarding PLSVC. Additionally, we have discussed the clinical implications and relevance of such congenital aberrancies, as well as of treatment-induced or disease-induced alterations in the anatomy of the thoracic central venous system, as they pertain to the general principles of successful placement of central venous access devices in cancer patients. Specifically regarding PLSVC, it is critical to recognize its presence during attempted central venous access device placement and to fully characterize the pattern of cardiac venous return (i.e., to the right atrium or to the left atrium) in any patient suspected of PLSVC prior to initiation of use of their central venous access device

    The strengths and limitations of routine staging before treatment with abdominal CT in colorectal cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Advanced colorectal cancer (CRC), either locally advanced, metastasized (mCRC) or both, is present in a relevant proportion of patients. The chances on curation of advanced CRC are continuously improving with modern multi-modality treatment options. For incurable CRC the focus lies on palliation of symptoms, which is not necessarily a resection of the primary tumor. Both situations motivate adequate staging before treatment in CRC. This prospective observational study evaluates the outcomes after the introduction of routine staging with abdominal CT before treatment.</p> <p>Methods</p> <p>In a prospective observational study of 612 consecutive patients (2007-2009), the ability of abdominal CT to find liver metastases (LM), peritoneal carcinomatosis (PC) and T4 stage in colon cancer (CC) was analysed.</p> <p>Results</p> <p>Advanced CRC was present in 58% of patients, mCRC in 31%. The ability to find LM was excellent (99%), cT4 stage CC good (86%) and PC poor (33%). In the group of surgical patients with emergency presentations, the incidences of both mCRC (51%) and locally advanced colon cancer (LACC) (69%) were higher than in the elective group (20% and 26% respectively). Staging tended to be omitted more often in the emergency group (35% versus 12% in elective surgery).</p> <p>Conclusions</p> <p>The strengths of staging with abdominal CT are to find LM and LACC, however it fails in diagnosing PC. On grounds of the incidence of advanced CRC, staging is warranted in patients with emergency presentations as well.</p

    Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach.</p> <p>Methods</p> <p>A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009.</p> <p>Results</p> <p>Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (81/719, 11.3%) than in the 8-gauge vacuum-assisted biopsy group (18/724, 2.5%) were recommended for further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for indeterminate/inconclusive findings seen on the original ultrasound-guided diagnostic breast biopsy procedure. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (54/719, 7.5%) than in the 8-gauge vacuum-assisted biopsy group (9/724, 1.2%) personally requested further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for a benign finding seen on the original ultrasound-guided diagnostic breast biopsy procedure.</p> <p>Conclusions</p> <p>In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information.</p

    Development of sentinel node localization and ROLL in breast cancer in Europe

    Get PDF
    The concept of a precise region in which to find the lymph nodes that drain the lymph directly from the primary tumor site can be traced back to a century ago to the observations of Jamieson and Dobson who described how cancer cells spread from cancer of the stomach in a single lymph node, which they called the â\u80\u9cprimary glandâ\u80\u9d. However, Cabanas was the first in 1977 to realize the importance of this concept in clinical studies following lymphography performed in patients with penile cancer. Thanks to Mortonâ\u80\u99s studies on melanoma in 1992, we began to understand the potential impact of the sentinel lymph node (SN) on the surgical treatment of this type of cancer. The use of a vital dye (blue dye) administered subdermally in the region surrounding the melanoma lesion led to the identification of the sentinel node, and the vital dye technique was subsequently applied to other types of solid tumors, e.g. breast, vulva. However, difficulties in using this technique in anatomical regions with deep lymphatic vessels, e.g. axilla, led to the development of lymphoscintigraphy, started by Alex and Krag in 1993 on melanoma and breast cancer and optimized by our group at European Institute of Oncology (IEO) in Milan in 1996. Today, lymphoscintigraphy is still considered as the most reliable method for the detection of the SN. In 1996, a new method for the localization of non-palpable breast lesion called radioguided occult lesion localization (ROLL) was also developed at IEO. Retrospective and prospective studies have since shown that the ROLL procedure permits the easy and accurate surgical removal of non-palpable breast lesions, overcoming the limitations of previous techniques such as the wire-guided localization. The purpose of this paper is to describe the evolution of SN biopsy and radioguided surgery in the management of breast cancer. We also include a review of the literature on the clinical scenarios in which SN biopsy in breast cancer is currently used, with particular reference to controversies and future prospects
    corecore