3 research outputs found

    Stability issues in the Tara tandem mirror experiment

    Get PDF

    Trapped Particle Stability for the Kinetic Stabilizer

    Full text link
    A kinetically stabilized axially symmetric tandem mirror (KSTM) uses the momentum flux of low-energy, unconfined particles that sample only the outer end-regions of the mirror plugs, where large favorable field-line curvature exists. The window of operation is determined for achieving MHD stability with tolerable energy drain from the kinetic stabilizer. Then MHD stable systems are analyzed for stability of the trapped particle mode. This mode is characterized by the detachment of the central-cell plasma from the kinetic stabilizer region without inducing field-line bending. Stability of the trapped particle mode is sensitive to the electron connection between the stabilizer and the end plug. It is found that the stability condition for the trapped particle mode is more constraining than the stability condition for the MHD mode, and it is challenging to satisfy the required power constraint. Furthermore a severe power drain may arise from the necessary connection of low-energy electrons in the kinetic stabilizer to the central region
    corecore