    Comparison of corneal surgically induced astigmatism calculations based on keratometry measurements made by 2 biometric devices

    No full text
    PURPOSE: To compare calculated corneal surgically induced astigmatism (SIA) by means of anterior-based keratometry (K) and total keratometry (TK) measurements made by 2 biometric devices. SETTING: Ophthalmology Department, Shaare Zedek Medical Center, Jerusalem, Israel. DESIGN: Retrospective, consecutive case series. METHODS: The medical records of patients who had undergone cataract surgery through a 2.4 mm temporal clear corneal incision by a single surgeon between March 2018 and November 2020 were retrospectively reviewed. Patients for whom there were preoperative and postoperative K measurements assessed by 2 biometric devices, optical low-coherence reflectometry (OLCR) (Lenstar LS900, Haag-Streit, software v. eye suite i/9.1.0.0) and swept-source optical coherence tomography (SS-OCT) (IOLMaster700, Carl Zeiss Meditec AG, software v. 1.80.6.60340), were identified. Corneal SIA (mean vector value) was calculated by vector analysis for 3 groups: SS-OCT(K), SS-OCT(TK), and OLCR(K). Bivariate analyses were applied for comparisons. RESULTS: 147 eyes of 123 patients (73 right eyes and 74 left eyes) were enrolled in the study. The right eye corneal SIA values were 0.09 diopters (D) @ 136 degrees, 0.09 D @ 141 degrees, and 0.07 D @ 123 degrees for the SS-OCT(K), SS-OCT(TK), and OLCR, respectively. The corresponding left eye corneal SIA values were 0.13 D @ 120 degrees, 0.11 D @ 123 degrees, and 0.08 D @ 120 degrees. There were no statistically significant differences between the mean vector value and variance of the corneal SIA for the right (P = .78 and P = .65) and the left (P = .75 and P = .37) eyes of the 3 groups. CONCLUSIONS: Corneal SIA values were low (0.07 to 0.13 D) and similar for the SS-OCT and the OLCR biometric devices with standard K measurements. TK measurements yielded similar corneal SIA values compared with anterior corneal-based measurements

    Comparison of corneal surgically induced astigmatism calculations based on keratometry measurements made by 2 biometric devices

    No full text
    PURPOSE: To compare calculated corneal surgically induced astigmatism (SIA) by means of anterior-based keratometry (K) and total keratometry (TK) measurements made by 2 biometric devices. SETTING: Ophthalmology Department, Shaare Zedek Medical Center, Jerusalem, Israel. DESIGN: Retrospective, consecutive case series. METHODS: The medical records of patients who had undergone cataract surgery through a 2.4 mm temporal clear corneal incision by a single surgeon between March 2018 and November 2020 were retrospectively reviewed. Patients for whom there were preoperative and postoperative K measurements assessed by 2 biometric devices, optical low-coherence reflectometry (OLCR) (Lenstar LS900, Haag-Streit, software v. eye suite i/9.1.0.0) and swept-source optical coherence tomography (SS-OCT) (IOLMaster700, Carl Zeiss Meditec AG, software v. 1.80.6.60340), were identified. Corneal SIA (mean vector value) was calculated by vector analysis for 3 groups: SS-OCT(K), SS-OCT(TK), and OLCR(K). Bivariate analyses were applied for comparisons. RESULTS: 147 eyes of 123 patients (73 right eyes and 74 left eyes) were enrolled in the study. The right eye corneal SIA values were 0.09 diopters (D) @ 136 degrees, 0.09 D @ 141 degrees, and 0.07 D @ 123 degrees for the SS-OCT(K), SS-OCT(TK), and OLCR, respectively. The corresponding left eye corneal SIA values were 0.13 D @ 120 degrees, 0.11 D @ 123 degrees, and 0.08 D @ 120 degrees. There were no statistically significant differences between the mean vector value and variance of the corneal SIA for the right (P = .78 and P = .65) and the left (P = .75 and P = .37) eyes of the 3 groups. CONCLUSIONS: Corneal SIA values were low (0.07 to 0.13 D) and similar for the SS-OCT and the OLCR biometric devices with standard K measurements. TK measurements yielded similar corneal SIA values compared with anterior corneal-based measurements

    Measured Corneal Astigmatism Versus Pseudophakic Predicted Refractive Astigmatism in Cataract Surgery Candidates

    No full text
    PURPOSE: To compare standard and total corneal astigmatism measurements to the predicted pseudophakic (nontoric) refractive astigmatism in candidates for cataract surgery. DESIGN: A retrospective, cross-sectional study. METHODS: A single-center analysis of consecutive eyes measured with a swept-source optical coherence tomography biometer at a large tertiary medical center between February 2018 and June 2020. Corneal astigmatism was calculated based on standard keratometry astigmatism (KA), total corneal astigmatism (TCA), and predicted refractive astigmatism (PRA) for a monofocal nontoric intraocular lens (IOL) implantation calculated by the Barrett toric calculator using the predicted posterior corneal astigmatism (PRA(Predicted-PCA)) and the measured posterior corneal astigmatism (PRA(Measured-PCA)) options. Separate analyses were performed for each eye. SETTING: Ophthalmology Department, Shaare Zedek Medical Center, Jerusalem, Israel. RESULTS: In total, 8152 eyes of 5320 patients (4221 right eyes [OD] and 3931 left eyes [OS], mean age 70.6±12.2 years, 54.2% females) were included in the study. The mean vector values (centroid) for KA, TCA, PRA(Predicted-PCA), and PRA(Measured-PCA) were 0.07 diopters [D] at 19.5°, 0.27 D at 7.5°, 0.44 D at 2.9°, and 0.43 D at 179.3°, respectively (P 0.5 D. CONCLUSIONS: Standard and total corneal astigmatism measurements differ significantly from the PRA by the Barrett toric calculator. The PRA, rather than the KA or TCA, should be used as the reference guide for astigmatism correction with toric IOL implantation

    Measured Corneal Astigmatism Versus Pseudophakic Predicted Refractive Astigmatism in Cataract Surgery Candidates

    No full text
    PURPOSE: To compare standard and total corneal astigmatism measurements to the predicted pseudophakic (nontoric) refractive astigmatism in candidates for cataract surgery. DESIGN: A retrospective, cross-sectional study. METHODS: A single-center analysis of consecutive eyes measured with a swept-source optical coherence tomography biometer at a large tertiary medical center between February 2018 and June 2020. Corneal astigmatism was calculated based on standard keratometry astigmatism (KA), total corneal astigmatism (TCA), and predicted refractive astigmatism (PRA) for a monofocal nontoric intraocular lens (IOL) implantation calculated by the Barrett toric calculator using the predicted posterior corneal astigmatism (PRA(Predicted-PCA)) and the measured posterior corneal astigmatism (PRA(Measured-PCA)) options. Separate analyses were performed for each eye. SETTING: Ophthalmology Department, Shaare Zedek Medical Center, Jerusalem, Israel. RESULTS: In total, 8152 eyes of 5320 patients (4221 right eyes [OD] and 3931 left eyes [OS], mean age 70.6±12.2 years, 54.2% females) were included in the study. The mean vector values (centroid) for KA, TCA, PRA(Predicted-PCA), and PRA(Measured-PCA) were 0.07 diopters [D] at 19.5°, 0.27 D at 7.5°, 0.44 D at 2.9°, and 0.43 D at 179.3°, respectively (P 0.5 D. CONCLUSIONS: Standard and total corneal astigmatism measurements differ significantly from the PRA by the Barrett toric calculator. The PRA, rather than the KA or TCA, should be used as the reference guide for astigmatism correction with toric IOL implantation