12 research outputs found

    Recent changes in the epidemiology and management of extended-spectrum β-lactamase-producing Enterobacteriaceae

    Get PDF
    Since 2000, Escherichia coli producing CTX-M enzymes (especially CTX-M-15) have emerged worldwide as important causes of community-onset urinary tract and blood stream infections due to extended-spectrum β-lactamase (ESBL) producing bacteria. Studies suggest that the sudden worldwide increase of CTX-M-15-producing E. coli is mostly due to a single clone named ST131 and that foreign travel to high-risk areas, such as the Indian subcontinent, play in part a role in the spread of this clone across different continents. Empiric antibiotic coverage for these resistant organisms should be considered in community patients presenting with sepsis involving the urinary tract, especially if a patient recently traveled to a high-risk area. If this emerging public health threat is ignored, it is possible that the medical community may be forced in the near future to use carbapenems as the first choice for the empirical treatment of serious infections associated with urinary tract infections originating in the community

    Population-based laboratory surveillance of Hafnia alvei isolates in a large Canadian health region

    Get PDF
    BACKGROUND: Hospital-based series have characterized Hafnia alvei primarily as an infrequent agent of polymicrobial nosocomial infections in males with underlying illness. METHODS: We conducted population-based laboratory surveillance in the Calgary Health Region during 2000–2005 to define the incidence, demographic risk factors for acquisition, and anti-microbial susceptibilities of Hafnia alvei isolates. RESULTS: A total of 138 patients with Hafnia alvei isolates were identified (2.1/100,000/year) and two-thirds were of community onset. Older age and female gender were important risk factors for acquisition. The most common focus of isolation was urine in 112 (81%), followed by lower respiratory tract in 10 (7%), and soft tissue in 5 (4%), and the majority (94; 68%) were mono-microbial. Most isolates were resistant to ampicillin (111;80%), cephalothin (106; 77%), amoxicillin/clavulanate (98; 71%), and cefazolin (95; 69%) but none to imipenem or ciprofloxacin. CONCLUSION: Hafnia alvei was most commonly isolated as a mono-microbial etiology from the urinary tract in women from the community. This study highlights the importance of population-based studies in accurately defining the epidemiology of an infectious disease

    Population-Based Surveillance for Hypermucoviscosity Klebsiella pneumoniae

    Get PDF
    The characteristics of hypermucoviscosity isolates among Klebsiella pneumoniae causing community-acquired bacteremia were investigated. The hypermucoviscous phenotype was present in 8.2% of K pneumoniae isolates, and was associated with rmpA and the K2 serotype; liver abscesses were the most common clinical presentation. The present analysis represents the first population-based surveillance study of hypermucoviscosity among K pneumoniae causing bacteremia

    Molecular epidemiology of extended-spectrum beta-lactamase-producing extra-intestinal pathogenic Escherichia coli strains over a 2-year period (2017-2019) from Zimbabwe

    Get PDF
    This study was designed to characterize extended-spectrum beta-lactamase (ESBL)–producing extra-intestinal pathogenic Escherichia coli (E.coli) (ExPEC) associated with urinary tract infections in nine different geographic regions of Zimbabwe over a 2-year period (2017–2019). A total of 48 ESBL-positive isolates from urine specimen were selected for whole-genome sequencing from 1246 Escherichia coli isolates biobanked at the National Microbiology Reference laboratory using phenotypic susceptibility testing results from the National Escherichia coli Surveillance Programme to provide representation of different geographical regions and year of isolation. The majority of ESBL E. coli isolates produced cefotaximase-Munich (CTX-M)-15, CTX-M-27, and CTX-M-14. In this study, sequence types (ST) 131 and ST410 were the most predominant antimicrobial-resistant clones and responsible for the increase in ESBL–producing E. coli strains since 2017. Novel ST131 complex strains were recorded during the period 2017 to 2018, thus showing the establishment and evolution of this antimicrobial-resistant ESBL clone in Zimbabwe posing an important public health threat. Incompatibility group F plasmids were predominant among ST131 and ST410 isolates with the following replicons recorded most frequently: F1:A2:B20 (9/19, 47%), F2:A1: B (5/19, 26%), and F1:A1:B49 (8/13, 62%). The results indicate the need for continuous tracking of different ESBL ExPEC clones on a global scale, while targeting specific STs (e.g. ST131 and ST410) through control programs will substantially decrease the spread of ESBLs among ExPEC

    Antimicrobial Resistance Surveillance Systems: Are Potential Biases Taken into Account?

    Full text link
    The objective of this study was to assess potential biases that may influence the validity of contemporary antimicrobial-resistant (AMR) pathogen surveillance systems. Although surveillance data have been widely published and used by researchers and decision makers, little attention has been devoted to the assessment of their validity. A Medline search was used to identify reports, in 2008, of laboratory-based AMR surveillance systems. Identified surveillance systems were appraised for six different types of bias. Scores were assigned as ‘2’ (good), ‘1’ (fair) and ‘0’ (poor) for each bias. The results of this assessment indicate that there are several potential biases that can influence the validity of AMR surveillance information and, therefore, the potential for bias should be considered in the interpretation and use of AMR surveillance data.BACKGROUND: The validity of surveillance systems has rarely been a topic of investigation.OBJECTIVE: To assess potential biases that may influence the validity of contemporary antimicrobial-resistant (AMR) pathogen surveillance systems.METHODS: In 2008, reports of laboratory-based AMR surveillance systems were identified by searching Medline. Surveillance systems were appraised for six different types of bias. Scores were assigned as ‘2’ (good), ‘1’ (fair) and ‘0’ (poor) for each bias.RESULTS: A total of 22 surveillance systems were included. All studies used appropriate denominator data and case definitions (score of 2). Most (n=18) studies adequately protected against case ascertainment bias (score = 2), with three studies and one study scoring 1 and 0, respectively. Only four studies were deemed to be free of significant sampling bias (score = 2), with 17 studies classified as fair, and one as poor. Eight studies had explicitly removed duplicates (score = 2). Seven studies removed duplicates, but lacked adequate definitions (score = 1). Seven studies did not report duplicate removal (score = 0). Eighteen of the studies were considered to have good laboratory methodology, three had some concerns (score = 1), and one was considered to be poor (score = 0).CONCLUSION: Contemporary AMR surveillance systems commonly have methodological limitations with respect to sampling and multiple counting and, to a lesser degree, case ascertainment and laboratory practices. The potential for bias should be considered in the interpretation of surveillance data.Peer Reviewe

    Population-Based Surveillance for Hypermucoviscosity Klebsiella pneumoniae Causing Community-Acquired Bacteremia in Calgary, Alberta

    Full text link
    The characteristics of hypermucoviscosity isolates among Klebsiella pneumoniae causing community-acquired bacteremia were investigated. The hypermucoviscous phenotype was present in 8.2% of K pneumoniae isolates, and was associated with rmpA and the K2 serotype; liver abscesses were the most common clinical presentation. The present analysis represents the first population-based surveillance study of hypermucoviscosity among K pneumoniae causing bacteremia.Peer Reviewe

    Clinical outcome of empiric antimicrobial therapy of bacteremia due to extended-spectrum beta-lactamase producing <it>Escherichia coli </it>and <it>Klebsiella pneumoniae</it>

    Full text link
    Abstract Background Prompt administration of adequate empiric antimicrobial therapy is a major determinant influencing the outcome of serious infections. The objective of this study was to describe empiric antimicrobial therapy employed and assess its effect on the outcome of patients bacteremic with extended-spectrum beta-lactamase (ESBL) producing Escherichia coli and Klebsiella pneumoniae. Findings A retrospective surveillance study of all patients with bacteremias caused by ESBL-producing E. coli and K. pneumoniae (EK-ESBL) from 2000-2007 in the Calgary Health Region was conducted. Data were available for 79 episodes of bacteremia among 76 patients. Forty-four (56%) were male, the median age was 70.0 yrs [interquartile range (IQR) 60.6-70.1 yrs], and 72 (91%) episodes were E. coli. Seventy-four episodes (94%) were treated with empiric therapy within the first 48 hours. A non-statistically significant increased mortality occurred in those treated empirically with a beta-lactam/beta-lactamase inhibitor combination (6/16; 38% vs. 10/53; 18%; p = 0.063) while empiric carbapenem therapy was associated with lower mortality (0/10 died vs. 16/53 (30%), p = 0.089). Only 42 (53%) episodes received adequate therapy within the first 48 hours. The median time to first adequate antibiotic therapy was 41.0 hours [IQR 5.8-59.5] (n = 75). The case-fatality rate was not different among those that received adequate compared to inadequate therapy by 48 hours as compared to inadequate empiric therapy (9/42; 21% vs. 7/37; 19%; p = 1.0). Conclusion Inadequate empiric therapy is common among patients with EK-ESBL bacteremia in our region but was not associated with adverse mortality outcome.</p
    corecore