6 research outputs found

    Retrospective analysis of ocular disorders and frequency of cesarean sections for ocular indications in 2000-2008 – our own experience

    Get PDF
    Summary 1. Evaluation of frequency of cesarean sections for ocular indications. 2. Analysis of ophthalmological disorders as indications for cesarean section. Material and methods: 4895 cesarean sections were performed (100 due to ocular indications) in the Department of Obstetrics, Female Pathology and Oncological Gynecology, between 2000 and 2008. Medical documentation was analyzed. Results: Among 4895 patients undergoing cesarean sections, 100 (2.04%) presented a written certification from an ophthalmologist suggesting this way of delivery. The frequency of c-sections due to ocular indications continued to increase between 2000-2005 and has been in decline since 2006. The most common ophthalmological disorders included myopia (57%), retinopathy (20%), glaucoma (5%), imminent retinal detachment (4%) and past retinal detachment (3%). In 45% of patients an eye pathology was the only reason for a cesarean section. Conclusion: 1. The frequency of cesarean sections due to ocular reasons in our material was 0.7%- 3.44%, average 2.04%. 2. Since 2006 the number of ocular indications for cesarean section has been decreasing. Nevertheless, it remains to be twice as high as in 2000. 3. The most common eye disorders leading to cesarean section were myopia and retinopathy. 4. In almost half of the patients the decision to conduct a cesarean section was based solely on ophthalmological indications

    Local recurrence and distant metastases 18 years after resection of the greater omentum hemangiopericytoma

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hemangiopericytoma occurs with increasing frequency in 5<sup>th </sup>decade of life and has prediction for retroperitoneum and extremities. A case of a local recurrence and metastases of hemangiopericytoma is described.</p> <p>Case presentation</p> <p>Recurrence of hemangiopericytoma in the greater omentum and the jejunal mesentery as well as metastases in the retroperitoneal space were diagnosed in a 61-year-old patient who had a hemangiopericytoma of the greater omentum excised 18 years before.</p> <p>Conclusion</p> <p>Because of the rarity of this disease and its typical clinical course associated with late recurrence and metastases, the authors decided to present this case emphasizing the necessity of systematic oncological follow-up after the end of treatment.</p

    Corneal Optical Densitometry in the Evaluation of 2-Year Graft Function Following Endothelial Keratoplasty

    No full text
    This study aimed to assess clinical application of the Scheimpflug corneal tomography for objective evaluation of corneal optical density in eyes undergoing Descemet’s stripping endothelial keratoplasty (DSEK). In this prospective study, 39 pseudophakic eyes with bullous keratopathy were enrolled. All eyes underwent primary DSEK. Ophthalmic examination included best corrected visual acuity (BCVA) measurement, biomicroscopy, Scheimpflug tomography, pachymetry, and endothelial cell count. All measurements were taken preoperatively and within a 2-year follow-up period. Gradual BCVA improvement was observed in all patients. After two years, the mean and median BCVA values were 0.18 logMAR. A decrease in central corneal thickness was noted only during the first 3 months postoperatively and was followed by a gradual increase. Corneal densitometry decreased constantly and most significantly in the first 3 months postoperatively. The consecutive decrease in endothelial cell count of the transplanted cornea was most significant during the first 6 months postoperatively. Six months postoperatively, the strongest correlation (Spearman’s r = −0.41) with BCVA was found for densitometry. This tendency was maintained throughout the entire follow-up period. Corneal densitometry is applicable for objective monitoring of early and late outcomes of endothelial keratoplasty, showing a higher correlation with visual acuity than pachymetry and endothelial cell density

    Przyczyny dyskwalifikacji z operacji laserowej korekcji wzroku

    No full text
    The aim of the article is to establish the reasons for disqualification from laser vision correction surgery and to compile data on the most common reasons for not qualifying for the procedure. The specific patients in which the procedure can be performed should be carefully considered. For people who are not qualified for surgery, there are many alternative methods of correcting vision defects.Celem pracy jest ustalenie przyczyn dyskwalifikacji z operacji laserowej korekcji wzroku oraz zestawienie danych dotyczących najczęstszych powodów niezakwalifikowania do zabiegu. Należy dokładnie rozważyć, u jakich pacjentów można go wykonać. Dla osób niezakwalifikowanych do zabiegu istnieje wiele alternatywnych metod korekcji wad wzroku

    Developments in Contact Lens Imaging: New Applications of Optical Coherence Tomography

    No full text
    Optical coherence tomography (OCT) is a high-speed and non-contact optical imaging technology widely used for noninvasive cross-sectional imaging of biological objects. Two main OCT technologies have been developed: time domain and Fourier domain technologies. The latter can be further divided into spectral domain OCT, which uses a broadband light source and a spectrometer as a detector, and swept source OCT, which employs a quickly-rotating laser source. Advances in OCT technology have made it one of the most helpful devices in ophthalmic practice. Fourier OCT has revolutionized imaging of the posterior segment of the eye, as well as of anterior structures and has enhanced the ability to diagnose and manage patients. It provides high-resolution information about the tear film, contact lens (CL), a qualitative and quantitative assessment of the anterior eye that is important in CL fitting, and allows possible eye surface changes while wearing CLs to be monitored. Potential swept source OCT technology applications include industrial processes of lens design and quality control. In this paper, we describe clinical applications ant outline a variety of multifunctional uses of OCT in the field of refractive error correction with CLs
    corecore