8 research outputs found

    Patient specific instrumentation in ACL reconstruction:a proof-of-concept cadaver experiment assessing drilling accuracy when using 3D printed guides

    Get PDF
    Introduction: Accurate positioning of the femoral tunnel in ACL reconstruction is of the utmost importance to reduce the risk of graft failure. Limited visibility during arthroscopy and a wide anatomical variance attribute to femoral tunnel malposition using conventional surgical techniques. The purpose of this study was to determine whether a patient specific 3D printed surgical guide allows for in vitro femoral tunnel positioning within 2 mm of the planned tunnel position. Materials and Methods: A patient specific guide for femoral tunnel positioning in ACL reconstruction was created for four human cadaveric knee specimens based on routine clinical MRI data. Fitting properties were judged by two orthopedic surgeons. MRI scanning was performed both pre- and post-procedure. The planned tunnel endpoint was compared to the actual drilled femoral tunnel. Results: This patient specific 3D printed guide showed a mean deviation of 5.0 mm from the center of the planned femoral ACL origin. Conclusion: In search to improve accuracy and consistency of femoral tunnel positioning in ACL reconstruction, the use of a patient specific 3D printed surgical guide is a viable option to explore further. The results are comparable to those of conventional techniques; however, further design improvements are necessary to improve accuracy and enhance reproducibility.</p

    Are torso asymmetry and torso displacements in a computer brace model associated with initial in-brace correction in adolescent idiopathic scoliosis?

    Get PDF
    Background: Lack of initial in-brace correction is strongly predictive for brace treatment failure in adolescent idiopathic scoliosis (AIS) patients. Computer-aided design (CAD) technology could be useful in quantifying the trunk in 3D and brace characteristics in order to further investigate the effect of brace modifications on initial in-brace correction and subsequently long-term brace treatment success. The purpose of this pilot study was to identify parameters obtained from 3D surface scans which influence the initial in-brace correction (IBC) in a Boston brace in patients with AIS.Methods: Twenty-fiveAIS patients receiving a CAD-based Boston brace were included in this pilot study consisting of 11 patients with Lenke classification type 1 and 14 with type 5 curves. The degree of torso asymmetry and segmental peak positive and negative torso displacements were analyzed with the use of patients’ 3D surface scans and brace models for potential correlations with IBC. Results: The mean IBC of the major curve on AP view was 15.9% (SD = 9.1%) for the Lenke type 1 curves, and 20.1% (SD = 13.9%) for the type 5 curves. The degree of torso asymmetry was weakly correlated with patient’s pre-brace major curve Cobb angle and negligible correlated with major curve IBC. Mostly weak or negligible correlations were observed between IBC and the twelve segmental peak displacements for both Lenke type 1 and 5 curves.Conclusion: Based on the results of this pilot study, the degree of torso asymmetry and segmental peak torso displacements in the brace model alone are not clearly associated with IBC.</p

    Patient specific instrumentation in ACL reconstruction:a proof-of-concept cadaver experiment assessing drilling accuracy when using 3D printed guides

    Get PDF
    Introduction: Accurate positioning of the femoral tunnel in ACL reconstruction is of the utmost importance to reduce the risk of graft failure. Limited visibility during arthroscopy and a wide anatomical variance attribute to femoral tunnel malposition using conventional surgical techniques. The purpose of this study was to determine whether a patient specific 3D printed surgical guide allows for in vitro femoral tunnel positioning within 2 mm of the planned tunnel position. Materials and Methods: A patient specific guide for femoral tunnel positioning in ACL reconstruction was created for four human cadaveric knee specimens based on routine clinical MRI data. Fitting properties were judged by two orthopedic surgeons. MRI scanning was performed both pre- and post-procedure. The planned tunnel endpoint was compared to the actual drilled femoral tunnel. Results: This patient specific 3D printed guide showed a mean deviation of 5.0 mm from the center of the planned femoral ACL origin. Conclusion: In search to improve accuracy and consistency of femoral tunnel positioning in ACL reconstruction, the use of a patient specific 3D printed surgical guide is a viable option to explore further. The results are comparable to those of conventional techniques; however, further design improvements are necessary to improve accuracy and enhance reproducibility.</p

    Are torso asymmetry and torso displacements in a computer brace model associated with initial in-brace correction in adolescent idiopathic scoliosis?

    Get PDF
    Background: Lack of initial in-brace correction is strongly predictive for brace treatment failure in adolescent idiopathic scoliosis (AIS) patients. Computer-aided design (CAD) technology could be useful in quantifying the trunk in 3D and brace characteristics in order to further investigate the effect of brace modifications on initial in-brace correction and subsequently long-term brace treatment success. The purpose of this pilot study was to identify parameters obtained from 3D surface scans which influence the initial in-brace correction (IBC) in a Boston brace in patients with AIS.Methods: Twenty-fiveAIS patients receiving a CAD-based Boston brace were included in this pilot study consisting of 11 patients with Lenke classification type 1 and 14 with type 5 curves. The degree of torso asymmetry and segmental peak positive and negative torso displacements were analyzed with the use of patients’ 3D surface scans and brace models for potential correlations with IBC. Results: The mean IBC of the major curve on AP view was 15.9% (SD = 9.1%) for the Lenke type 1 curves, and 20.1% (SD = 13.9%) for the type 5 curves. The degree of torso asymmetry was weakly correlated with patient’s pre-brace major curve Cobb angle and negligible correlated with major curve IBC. Mostly weak or negligible correlations were observed between IBC and the twelve segmental peak displacements for both Lenke type 1 and 5 curves.Conclusion: Based on the results of this pilot study, the degree of torso asymmetry and segmental peak torso displacements in the brace model alone are not clearly associated with IBC.</p

    Are torso asymmetry and torso displacements in a computer brace model associated with initial in-brace correction in adolescent idiopathic scoliosis?

    Get PDF
    Background: Lack of initial in-brace correction is strongly predictive for brace treatment failure in adolescent idiopathic scoliosis (AIS) patients. Computer-aided design (CAD) technology could be useful in quantifying the trunk in 3D and brace characteristics in order to further investigate the effect of brace modifications on initial in-brace correction and subsequently long-term brace treatment success. The purpose of this pilot study was to identify parameters obtained from 3D surface scans which influence the initial in-brace correction (IBC) in a Boston brace in patients with AIS.Methods: Twenty-fiveAIS patients receiving a CAD-based Boston brace were included in this pilot study consisting of 11 patients with Lenke classification type 1 and 14 with type 5 curves. The degree of torso asymmetry and segmental peak positive and negative torso displacements were analyzed with the use of patients’ 3D surface scans and brace models for potential correlations with IBC. Results: The mean IBC of the major curve on AP view was 15.9% (SD = 9.1%) for the Lenke type 1 curves, and 20.1% (SD = 13.9%) for the type 5 curves. The degree of torso asymmetry was weakly correlated with patient’s pre-brace major curve Cobb angle and negligible correlated with major curve IBC. Mostly weak or negligible correlations were observed between IBC and the twelve segmental peak displacements for both Lenke type 1 and 5 curves.Conclusion: Based on the results of this pilot study, the degree of torso asymmetry and segmental peak torso displacements in the brace model alone are not clearly associated with IBC.</p

    The Accuracy of Patient-Specific Spinal Drill Guides Is Non-Inferior to Computer-Assisted Surgery:The Results of a Split-Spine Randomized Controlled Trial

    Get PDF
    In recent years, patient-specific spinal drill guides (3DPGs) have gained widespread popularity. Several studies have shown that the accuracy of screw insertion with these guides is superior to that obtained using the freehand insertion technique, but there are no studies that make a comparison with computer-assisted surgery (CAS). The aim of this study was to determine whether the accuracy of insertion of spinal screws using 3DPGs is non-inferior to insertion via CAS. A randomized controlled split-spine study was performed in which 3DPG and CAS were randomly assigned to the left or right sides of the spines of patients undergoing fixation surgery. The 3D measured accuracy of screw insertion was the primary study outcome parameter. Sixty screws inserted in 10 patients who completed the study protocol were used for the non-inferiority analysis. The non-inferiority of 3DPG was demonstrated for entry-point accuracy, as the upper margin of the 95% CI (−1.01 mm–0.49 mm) for the difference between the means did not cross the predetermined non-inferiority margin of 1 mm (p < 0.05). We also demonstrated non-inferiority of 3D angular accuracy (p < 0.05), with a 95% CI for the true difference of −2.30◦–1.35◦, not crossing the predetermined non-inferiority margin of 3◦ (p < 0.05). The results of this randomized controlled trial (RCT) showed that 3DPGs provide a non-inferior alternative to CAS in terms of screw insertion accuracy and have considerable potential as a navigational technique in spinal fixation

    A Two-Step Approach for 3D-Guided Patient-Specific Corrective Limb Osteotomies

    Get PDF
    Background: Corrective osteotomy surgery for long bone anomalies can be very challenging since deformation of the bone is often present in three dimensions. We developed a two-step approach for 3D-planned corrective osteotomies which consists of a cutting and reposition guide in combination with a conventional osteosynthesis plate. This study aimed to assess accuracy of the achieved corrections using this two-step technique. Methods: All patients (≥12 years) treated for post-traumatic malunion with a two-step 3D-planned corrective osteotomy within our center in 2021 were prospectively included. Three-dimensional virtual models of the planned outcome and the clinically achieved outcome were obtained and aligned. Postoperative evaluation of the accuracy of performed corrections was assessed by measuring the preoperative and postoperative alignment error in terms of angulation, rotation and translation. Results: A total of 10 patients were included. All corrective osteotomies were performed according to the predetermined surgical plan without any complications. The preoperative deformities ranged from 7.1 to 27.5° in terms of angulation and 5.3 to 26.1° in terms of rotation. The achieved alignment deviated on average 2.1 ± 1.0 and 3.4 ± 1.6 degrees from the planning for the angulation and rotation, respectively. Conclusions: A two-step approach for 3D-guided patient-specific corrective limb osteotomies is reliable, feasible and accurate

    A Two-Step Approach for 3D-Guided Patient-Specific Corrective Limb Osteotomies

    Get PDF
    Background: Corrective osteotomy surgery for long bone anomalies can be very challenging since deformation of the bone is often present in three dimensions. We developed a two-step approach for 3D-planned corrective osteotomies which consists of a cutting and reposition guide in combination with a conventional osteosynthesis plate. This study aimed to assess accuracy of the achieved corrections using this two-step technique.Methods: All patients (≥12 years) treated for post-traumatic malunion with a two-step 3D-planned corrective osteotomy within our center in 2021 were prospectively included. Three-dimensional virtual models of the planned outcome and the clinically achieved outcome were obtained and aligned. Postoperative evaluation of the accuracy of performed corrections was assessed by measuring the preoperative and postoperative alignment error in terms of angulation, rotation and translation.Results: A total of 10 patients were included. All corrective osteotomies were performed according to the predetermined surgical plan without any complications. The preoperative deformities ranged from 7.1 to 27.5° in terms of angulation and 5.3 to 26.1° in terms of rotation. The achieved alignment deviated on average 2.1 ± 1.0 and 3.4 ± 1.6 degrees from the planning for the angulation and rotation, respectively.Conclusions: A two-step approach for 3D-guided patient-specific corrective limb osteotomies is reliable, feasible and accurate.</p
    corecore