16 research outputs found

    Complex myograph allows the examination of complex muscle contractions for the assessment of muscle force, shortening, velocity, and work in vivo

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The devices used for <it>in vivo </it>examination of muscle contractions assess only pure force contractions and the so-called isokinetic contractions. In isokinetic experiments, the extremity and its muscle are artificially moved with constant velocity by the measuring device, while a tetanic contraction is induced in the muscle, either by electrical stimulation or by maximal voluntary activation. With these systems, experiments cannot be performed at pre-defined, constant muscle length, single contractions cannot be evaluated individually and the separate examination of the isometric and the isotonic components of single contractions is not possible.</p> <p>Methods</p> <p>The myograph presented in our study has two newly developed technical units, i.e. a). a counterforce unit which can load the muscle with an adjustable, but constant force and b). a length-adjusting unit which allows for both the stretching and the contraction length to be infinitely adjustable independently of one another. The two units support the examination of complex types of contraction and store the counterforce and length-adjusting settings, so that these conditions may be accurately reapplied in later sessions.</p> <p>Results</p> <p>The measurement examples presented show that the muscle can be brought to every possible pre-stretching length and that single isotonic or complex isometric-isotonic contractions may be performed at every length. The applied forces act during different phases of contraction, resulting into different pre- and after-loads that can be kept constant – uninfluenced by the contraction. Maximal values for force, shortening, velocity and work may be obtained for individual muscles. This offers the possibility to obtain information on the muscle status and to monitor its changes under non-invasive measurement conditions.</p> <p>Conclusion</p> <p>With the Complex Myograph, the whole spectrum of a muscle's mechanical characteristics may be assessed.</p

    Thromboelastometry-guided administration of fibrinogen concentrate for the treatment of excessive intraoperative bleeding in thoracoabdominal aortic aneurysm surgery

    Get PDF
    ObjectiveThoracoabdominal aortic aneurysm operations are associated with extensive blood loss and high requirements for allogeneic blood product transfusion. We assessed the efficacy of intraoperative post–cardiopulmonary bypass administration of fibrinogen concentrate in elective thoracoabdominal aortic aneurysm surgery.MethodsIn a retrospective group (group A, n = 12) of patients undergoing elective thoracoabdominal aortic aneurysm surgery, clinically relevant diffuse bleeding after weaning from cardiopulmonary bypass was treated with allogeneic blood products (platelet concentrates, followed by fresh frozen plasma) according to a predetermined algorithm.In a prospective group (group F, n = 6) a first therapy step with fibrinogen concentrate was added to the algorithm. The dose of fibrinogen concentrate was estimated by using thromboelastometric data (ROTEM FIBTEM). Before each step of hemostatic therapy, blood loss in the range of 60 to 250 g per 5 minutes was confirmed.ResultsIn group F, administration of 7.8 ± 2.7 g of fibrinogen concentrate established hemostasis, completely avoiding intraoperative transfusion of fresh frozen plasma and platelet concentrates. Transfusion of blood products after cardiopulmonary bypass and during the 24 hours after surgical intervention was markedly lower in group F than in group A (2.5 vs 16.4 units; 4/6 patients in group F required no transfusion of blood products), as was 24-hour drainage volume (449 vs 1092 mL). Fibrinogen plasma levels, standard coagulation parameters, and hemoglobin and hematocrit values were comparable between the 2 groups on the first postoperative day.ConclusionsFIBTEM-guided post–cardiopulmonary bypass administration of fibrinogen concentrate resulted in improved intraoperative management of coagulopathic bleeding in thoracoabdominal aortic aneurysm operations and reduced transfusion and 24-hour drainage volume

    Lack of influence of the COX inhibitors metamizol and diclofenac on platelet GPIIb/IIIa and P-selectin expression in vitro

    Get PDF
    BACKGROUND: The effect of non-steroidal anti-inflammatory drugs (NSAIDs) for reduced platelet aggregation and thromboxane A(2 )synthesis has been well documented. However, the influence on platelet function is not fully explained. Aim of this study was to examine the influence of the COX-1 inhibiting NSAIDs, diclofenac and metamizol on platelet activation and leukocyte-platelet complexes, in vitro. Surface expression of GPIIb/IIIa and P-selectin on platelets, and the percentage of platelet-leukocyte complexes were investigated. METHODS: Whole blood was incubated with three different concentrations of diclofenac and metamizol for 5 and 30 minutes, followed by activation with TRAP-6 and ADP. Rates of GPIIb/IIIa and P-selectin expression, and the percentage of platelet-leukocyte complexes were analyzed by a flow-cytometric assay. RESULTS: There were no significant differences in the expression of GPIIb/IIIa and P-selectin, and in the formation of platelet-leukocyte complexes after activation with ADP and TRAP-6, regarding both the time of incubation and the concentrations of diclofenac and metamizol. CONCLUSIONS: Accordingly, the inhibitory effect of diclofenac and metamizol on platelet aggregation is not related to a reduced surface expression of P-selectin and GPIIb/IIIa on platelets

    In vivo myograph measurement of muscle contraction at optimal length

    Get PDF
    We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations

    Assessment of precision and reproducibility of a new myograph

    Get PDF
    The new myograph is a highly reliable measuring device with which the adductor pollicis can be investigated at the optimum length. It has the potential to become a reliable and valid tool for diagnostic in the clinical setting and for monitoring neuromuscular diseases
    corecore