525 research outputs found
Multiple Effects of Prefrontal Lesions on Task-Switching
This study examined the performance of 41 patients with focal prefrontal cortical lesions and 38 healthy controls on a task-switching procedure. Three different conditions were evaluated: single tasks without switches and two switching tasks with the currently relevant task signalled either 1500 ms (Long Cue) or 200 ms (Short Cue) before the stimulus. Patients with Superior Medial lesions showed both a general slowing of reaction time (RT) and a significantly increased switch cost as measured by RT. No other prefrontal group showed this increased reaction time switch cost. Increased error rates in the switching conditions, on the other hand, were observed in patients with Inferior Medial lesions and, to a lesser extent, ones with Superior Medial lesions. Patients with left dorsolateral lesions (9/46v) showed slower learning of the task as indicated by a high error rate early on. Several different processes are involved in task-switching and these are selectively disrupted by lesions to specific areas of the frontal lobes
Hilbert-Huang versus Morlet wavelet transformation on mismatch negativity of children in uninterrupted sound paradigm
Background.
Compared to the waveform or spectrum analysis of event-related potentials (ERPs), time-frequency representation (TFR) has the advantage of revealing the ERPs time and frequency domain information simultaneously. As the human brain could be modeled as a complicated nonlinear system, it is interesting from the view of psychological knowledge to study the performance of the nonlinear and linear time-frequency representation methods for ERP research. In this study Hilbert-Huang transformation (HHT) and Morlet wavelet transformation (MWT) were performed on mismatch negativity (MMN) of children. Participants were 102 children aged 8–16 years. MMN was elicited in a passive oddball paradigm with duration deviants. The stimuli consisted of an uninterrupted sound including two alternating 100 ms tones (600 and 800 Hz) with infrequent 50 ms or 30 ms 600 Hz deviant tones. In theory larger deviant should elicit larger MMN. This theoretical expectation is used as a criterion to test two TFR methods in this study. For statistical analysis MMN support to absence ratio (SAR) could be utilized to qualify TFR of MMN.
Results.
Compared to MWT, the TFR of MMN with HHT was much sharper, sparser, and clearer. Statistically, SAR showed significant difference between the MMNs elicited by two deviants with HHT but not with MWT, and the larger deviant elicited MMN with larger SAR.
Conclusion.
Support to absence ratio of Hilbert-Huang Transformation on mismatch negativity meets the theoretical expectations, i.e., the more deviant stimulus elicits larger MMN. However, Morlet wavelet transformation does not reveal that. Thus, HHT seems more appropriate in analyzing event-related potentials in the time-frequency domain. HHT appears to evaluate ERPs more accurately and provide theoretically valid information of the brain responses.peerReviewe
Intra-oral compartment pressures: a biofunctional model and experimental measurements under different conditions of posture
Oral posture is considered to have a major influence on the development and reoccurrence of malocclusion. A biofunctional model was tested with the null hypotheses that (1) there are no significant differences between pressures during different oral functions and (2) between pressure measurements in different oral compartments in order to substantiate various postural conditions at rest by intra-oral pressure dynamics. Atmospheric pressure monitoring was simultaneously carried out with a digital manometer in the vestibular inter-occlusal space (IOS) and at the palatal vault (sub-palatal space, SPS). Twenty subjects with normal occlusion were evaluated during the open-mouth condition (OC), gently closed lips (semi-open compartment condition, SC), with closed compartments after the generation of a negative pressure (CCN) and swallowing (SW). Pressure curve characteristics were compared between the different measurement phases (OC, SC, CCN, SW) as well as between the two compartments (IOS, SPS) using analysis of variance and Wilcoxon matched-pairs tests adopting a significance level of α = 0.05. Both null hypotheses were rejected. Average pressures (IOS, SPS) in the experimental phases were 0.0, −0.08 (OC); −0.16, −1.0 (SC); −48.79, −81.86 (CCN); and −29.25, −62.51 (SW) mbar. CCN plateau and peak characteristics significantly differed between the two compartments SPS and IOS. These results indicate the formation of two different intra-oral functional anatomical compartments which provide a deeper understanding of orofacial biofunctions and explain previous observations of negative intra-oral pressures at rest
A Fast and Reliable Method for Simultaneous Waveform, Amplitude and Latency Estimation of Single-Trial EEG/MEG Data
The amplitude and latency of single-trial EEG/MEG signals may provide valuable information concerning human brain functioning. In this article we propose a new method to reliably estimate single-trial amplitude and latency of EEG/MEG signals. The advantages of the method are fourfold. First, no a-priori specified template function is required. Second, the method allows for multiple signals that may vary independently in amplitude and/or latency. Third, the method is less sensitive to noise as it models data with a parsimonious set of basis functions. Finally, the method is very fast since it is based on an iterative linear least squares algorithm. A simulation study shows that the method yields reliable estimates under different levels of latency variation and signal-to-noise ratioÕs. Furthermore, it shows that the existence of multiple signals can be correctly determined. An application to empirical data from a choice reaction time study indicates that the method describes these data accurately
Evidence for Training-Induced Plasticity in Multisensory Brain Structures: An MEG Study
Multisensory learning and resulting neural brain plasticity have recently become a topic of renewed interest in human cognitive neuroscience. Music notation reading is an ideal stimulus to study multisensory learning, as it allows studying the integration of visual, auditory and sensorimotor information processing. The present study aimed at answering whether multisensory learning alters uni-sensory structures, interconnections of uni-sensory structures or specific multisensory areas. In a short-term piano training procedure musically naive subjects were trained to play tone sequences from visually presented patterns in a music notation-like system [Auditory-Visual-Somatosensory group (AVS)], while another group received audio-visual training only that involved viewing the patterns and attentively listening to the recordings of the AVS training sessions [Auditory-Visual group (AV)]. Training-related changes in cortical networks were assessed by pre- and post-training magnetoencephalographic (MEG) recordings of an auditory, a visual and an integrated audio-visual mismatch negativity (MMN). The two groups (AVS and AV) were differently affected by the training. The results suggest that multisensory training alters the function of multisensory structures, and not the uni-sensory ones along with their interconnections, and thus provide an answer to an important question presented by cognitive models of multisensory training
Neutronic Design and Measured Performance of the Low Energy Neutron Source (LENS) Target Moderator Reflector Assembly
The Low Energy Neutron Source (LENS) is an accelerator-based pulsed cold
neutron facility under construction at the Indiana University Cyclotron
Facility (IUCF). The idea behind LENS is to produce pulsed cold neutron beams
starting with ~MeV neutrons from (p,n) reactions in Be which are moderated to
meV energies and extracted from a small solid angle for use in neutron
instruments which can operate efficiently with relatively broad (~1 msec)
neutron pulse widths. Although the combination of the features and operating
parameters of this source is unique at present, the neutronic design possesses
several features similar to those envisioned for future neutron facilities such
as long-pulsed spallation sources (LPSS) and very cold neutron (VCN) sources.
We describe the underlying ideas and design details of the
target/moderator/reflector system (TMR) and compare measurements of its
brightness, energy spectrum, and emission time distribution under different
moderator configurations with MCNP simulations. Brightness measurements using
an ambient temperature water moderator agree with MCNP simulations within the
20% accuracy of the measurement. The measured neutron emission time
distribution from a solid methane moderator is in agreement with simulation and
the cold neutron flux is sufficient for neutron scattering studies of
materials. We describe some possible modifications to the existing design which
would increase the cold neutron brightness with negligible effect on the
emission time distribution.Comment: This is a preprint version of an article which has been published in
Nuclear Instruments and Methods in Physics Research A 587 (2008) 324-341.
http://dx.doi.org/10.1016/j.nima.2007.12.04
- …